The DOI matches its Crossref record; 27 of the 30 references it cites were found in a registry or an index.
Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g ‐factor penalty
Open accessAbstract
Simultaneous multislice Echo Planar Imaging (EPI) acquisition using parallel imaging can decrease the acquisition time for diffusion imaging and allow full-brain, high-resolution functional MRI (fMRI) acquisitions at a reduced repetition time (TR). However, the unaliasing of simultaneously acquired, closely spaced slices can be difficult, leading to a high g-factor penalty. We introduce a method to create interslice image shifts in the phase encoding direction to increase the distance between aliasing pixels. The shift between the slices is induced using sign- and amplitude-modulated slice-select gradient blips simultaneous with the EPI phase encoding blips. This achieves the desired shifts but avoids an undesired "tilted voxel" blurring artifact associated with previous methods. We validate the method in 3× slice-accelerated spin-echo and gradient-echo EPI at 3 T and 7 T using 32-channel radio frequency (RF) coil brain arrays. The Monte-Carlo simulated average g-factor penalty of the 3-fold slice-accelerated acquisition with interslice shifts is <1% at 3 T (compared with 32% without slice shift). Combining 3× slice acceleration with 2× inplane acceleration, the g-factor penalty becomes 19% at 3 T and 10% at 7 T (compared with 41% and 23% without slice shift). We demonstrate the potential of the method for accelerating diffusion imaging by comparing the fiber orientation uncertainty, where the 3-fold faster acquisition showed no noticeable degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
““multiband accelerated EPI” acquires multiple slices simultaneously [39, 40]. Such approaches enable major improvements in spatial and/or temporal resolution, for example acquiring data with 2mm spatial resolution in less than a second.”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellús̆, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,311
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,145
Handbook of MRI Pulse Sequences
Bernstein, M. A., King, K. F., & Zhou, X. J. (2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,641
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,229
Self-citationSelective averaging of rapidly presented individual trials using fMRI
Dale, A. M., & Buckner, R. L. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:5 · Cited by 1,034
In vivo1H NMR spectroscopy of rat brain at 1 ms echo time
Tk�?, I., uk, Z. S., Choi, I., & Rolf Gruetter, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4 · Cited by 1,024
Magnetic field and tissue dependencies of human brain longitudinal 1 H 2 O relaxation in vivo
Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Uǧurbil, K., & SPRINGER, C. S. J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21122 · Cited by 651
Breuer, F., Blaimer, M., Heidemann, R. M., Mueller, M. F., Griswold, M. A., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20401 · Cited by 637
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 441
General formulation for quantitative G‐factor calculation in GRAPPA reconstructions
Breuer, F., Kannengießer, S., Blaimer, M., Seiberlich, N., Jakob, P. M., & Griswold, M. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22066 · Cited by 218
Water diffusion, T2, and compartmentation in frog sciatic nerve
Peled, S., Cory, D. G., Raymond, S. A., Kirschner, D. A., & Jolesz, F. A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5 · Cited by 193
Simultaneous echo refocusing in EPI
Feinberg, D. A., Reese, T. G., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10227 · Cited by 89
Self-citationAccelerated volumetric MRI with a SENSE/GRAPPA combination
Blaimer, M., Breuer, F., Seiberlich, N., Mueller, M. F., Heidemann, R. M., Jellús̆, V., Wiggins, G. C., Wald, L. L., Griswold, M. A., & Jakob, P. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20632 · Cited by 79
Self-citationSimultaneous multislice acquisition of MR images
Weaver, J. B. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910080305 · Cited by 66
Parent-Of-Origin Effects in Autism Identified through Genome-Wide Linkage Analysis of 16,000 SNPs
Fradin, D., Cheslack‐Postava, K., Ladd‐Acosta, C., Newschaffer, C. J., Chakravarti, A., Arking, D. E., Feinberg, A. P., & Fallin, M. D. (2010) · PLoS ONE · doi:10.1371/journal.pone.0012513 · Cited by 65
Reese, T. G., Benner, T., Wang, R., Feinberg, D. A., & Wedeen, V. J. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21497 · Cited by 58
Self-citationEcho-Volumar Imaging (EVI) of the Brain at 3.0 T
Mansfield, P. R., Coxon, R., & Hykin, J. (1995) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199511000-00002 · Cited by 57
High temporal resolution functional MRI using parallel echo volumar imaging
Rabrait‐Lerman, C., Ciuciu, P., Ribés, A., Poupon, C., Leroux, P., Dehaene‐Lambertz, G., Bihan, D. L., & Lethimonnier, F. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21329 · Cited by 51
Feinberg, D. A., & Jakab, P. D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160209 · Cited by 45
Improved echo volumar imaging (EVI) for functional MRI
van der Zwaag, W., Francis, S., & Bowtell, R. W. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21080 · Cited by 41
Rapid three-dimensional functional magnetic resonance imaging of the initial negative BOLD response
Lindquist, M. A., Zhang, C.-H., Glover, G. H., & Shepp, L. A. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.12.016 · Cited by 28
Simultaneous parallel inclined readout image technique
Paley, M. N. J., Lee, K. J., Wild, J. M., Griffiths, P. D., & WHITBY, E. H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.019 · Cited by 23
Larkman (2001) · doi:10.1002/1522-2586(200102)13:2
Flagged first, then by citations
3 of the 30 references couldn’t be matched to a known paper.
Research works printed but not linked: 5
- WitzelT PolimeniJR WigginsGC LinF‐H BiberS HammM SeethamrajuR WaldLL.Single‐shot echo‐volumar imaging using highly parallel detection. In: Proceedings of the 16th annual meeting of ISMRM Toronto Canada 2008. p2367.
- WuEL ChenJ‐H ChiuehT‐D.Wideband MRI: a new dimension of MR image acceleration. In: Proceedings of the 17th annual meeting of ISMRM Hawaii USA 2009. p2678.
- NunesRG HajnalJV GolayX LarkmanDJ.Simultaneous slice excitation and reconstruction for single shot EPI. In: Proceedings of the 14th annual meeting of ISMRM Seattle Washington USA 2006. p293.
- SetsompopK GagoskiBA PolimeniJ WitzelTW WedeenVJ WaldLL.Blipped CAIPIRHINA for simultaneous multi‐slice EPI with reducedg‐factor penalty. In: Proceedings of the 18th annual meeting of ISMRM Stockholm Sweden 2010. p551.
- KeilB TriantafyllouC HammM WaldLL.Design optimization of a 32‐channel head coil at 7 T. In: Proceedings of the 18th annual meeting of ISMRM Stockholm Sweden 2010. p1493.
Cited by
Sorted by citations
The WU-Minn Human Connectome Project: An overview
Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E. J., Yacoub, E., & Ugurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.041 · Cited by 5,651
Andersson, J., & Sotiropoulos, S. N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,439
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Multimodal population brain imaging in the UK Biobank prospective epidemiological study
Miller, K. L., Alfaro-Almagro, F., Bangerter, N. K., Thomas, D. L., Yacoub, E., Xu, J., Bartsch, A. J., Jbabdi, S., Sotiropoulos, S. N., Andersson, J. L. R., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4393 · Cited by 2,020
Resting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
Metadata
- Authors
- Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L.
- Affiliations
- Harvard University (US)
- Massachusetts Institute of Technology (US)
- Massachusetts General Hospital (US)
- Corresponding author
- Setsompop, Kawin
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-08-19
- Volume
- 67
- Issue
- 5
- Pages
- 1210-1224
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- PMC
- PMC3323676
- OpenAlex
- W2053759320
- Cited by
- 1,285
- References
- 30
- Citations by year
- 2026: 65 · 2025: 89 · 2024: 79 · 2023: 74 · 2022: 102 · 2021: 121 · 2020: 110 · 2019: 133 · 2018: 122 · 2017: 118 · 2016: 89 · 2015: 76 · 2014: 44 · 2013: 45 · 2012: 14
- FWCI
- 25.71
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- 16 National Institutes of Health Institutes and Centers that support the NIH Blueprint for Neuroscience (K99EB012107, R01EB006847, R01EB007942 (NIH NIBIB grants), P41RR14075 (NCRR grant))
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- parallel imaging, phase encoding, aliasing, functional MRI, spin-echo EPI, gradient-echo EPI
- MeSH terms
- Algorithms, Brain, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Pattern Recognition, Automated, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts, Echo-Planar Imaging, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review