The DOI matches its Crossref record; 27 of the 30 references it cites were found in a registry or an index.
Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g ‐factor penalty
Open accessAbstract
Simultaneous multislice Echo Planar Imaging (EPI) acquisition using parallel imaging can decrease the acquisition time for diffusion imaging and allow full-brain, high-resolution functional MRI (fMRI) acquisitions at a reduced repetition time (TR). However, the unaliasing of simultaneously acquired, closely spaced slices can be difficult, leading to a high g-factor penalty. We introduce a method to create interslice image shifts in the phase encoding direction to increase the distance between aliasing pixels. The shift between the slices is induced using sign- and amplitude-modulated slice-select gradient blips simultaneous with the EPI phase encoding blips. This achieves the desired shifts but avoids an undesired "tilted voxel" blurring artifact associated with previous methods. We validate the method in 3× slice-accelerated spin-echo and gradient-echo EPI at 3 T and 7 T using 32-channel radio frequency (RF) coil brain arrays. The Monte-Carlo simulated average g-factor penalty of the 3-fold slice-accelerated acquisition with interslice shifts is <1% at 3 T (compared with 32% without slice shift). Combining 3× slice acceleration with 2× inplane acceleration, the g-factor penalty becomes 19% at 3 T and 10% at 7 T (compared with 41% and 23% without slice shift). We demonstrate the potential of the method for accelerating diffusion imaging by comparing the fiber orientation uncertainty, where the 3-fold faster acquisition showed no noticeable degradation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
““multiband accelerated EPI” acquires multiple slices simultaneously [39, 40]. Such approaches enable major improvements in spatial and/or temporal resolution, for example acquiring data with 2mm spatial resolution in less than a second.”
From Functional connectomics from resting-state fMRI (2013) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellús̆, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,311
Characterization and propagation of uncertainty in diffusion-weighted MR imaging
Behrens, T. E. J., Woolrich, M. W., Jenkinson, M., Johansen‐Berg, H., Nunes, R. G., Clare, S., Matthews, P. M., Brady, J. M., & Smith, S. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10609 · Cited by 3,038
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,145
Handbook of MRI Pulse Sequences
Bernstein, M. A., King, K. F., & Zhou, X. J. (2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,641
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,229
Self-citationSelective averaging of rapidly presented individual trials using fMRI
Dale, A. M., & Buckner, R. L. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:5 · Cited by 1,034
In vivo1H NMR spectroscopy of rat brain at 1 ms echo time
Tk�?, I., uk, Z. S., Choi, I., & Rolf Gruetter, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4 · Cited by 1,024
Research works printed but not linked: 5
- WitzelT PolimeniJR WigginsGC LinF‐H BiberS HammM SeethamrajuR WaldLL.Single‐shot echo‐volumar imaging using highly parallel detection. In: Proceedings of the 16th annual meeting of ISMRM Toronto Canada 2008. p2367.
- WuEL ChenJ‐H ChiuehT‐D.Wideband MRI: a new dimension of MR image acceleration. In: Proceedings of the 17th annual meeting of ISMRM Hawaii USA 2009. p2678.
- NunesRG HajnalJV GolayX LarkmanDJ.Simultaneous slice excitation and reconstruction for single shot EPI. In: Proceedings of the 14th annual meeting of ISMRM Seattle Washington USA 2006. p293.
- SetsompopK GagoskiBA PolimeniJ WitzelTW WedeenVJ WaldLL.Blipped CAIPIRHINA for simultaneous multi‐slice EPI with reducedg‐factor penalty. In: Proceedings of the 18th annual meeting of ISMRM Stockholm Sweden 2010. p551.
- KeilB TriantafyllouC HammM WaldLL.Design optimization of a 32‐channel head coil at 7 T. In: Proceedings of the 18th annual meeting of ISMRM Stockholm Sweden 2010. p1493.
Cited by
Sorted by citations
The WU-Minn Human Connectome Project: An overview
Van Essen, D. C., Smith, S. M., Barch, D. M., Behrens, T. E. J., Yacoub, E., & Ugurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.041 · Cited by 5,651
Andersson, J., & Sotiropoulos, S. N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,439
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Multimodal population brain imaging in the UK Biobank prospective epidemiological study
Miller, K. L., Alfaro-Almagro, F., Bangerter, N. K., Thomas, D. L., Yacoub, E., Xu, J., Bartsch, A. J., Jbabdi, S., Sotiropoulos, S. N., Andersson, J. L. R., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4393 · Cited by 2,020
Resting-state fMRI in the human connectome project
Smith, S. M., Beckmann, C. F., Andersson, J., Auerbach, E. J., Bijsterbosch, J., Douaud, G., Duff, E., Feinberg, D. A., Griffanti, L., Harms, M. P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.039 · Cited by 1,502
Griffanti, L., Salimi‐Khorshidi, G., Beckmann, C. F., Auerbach, E. J., Douaud, G., Sexton, C. E., Zsoldos, E., Ebmeier, K. P., Filippini, N., Mackay, C. E., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.034 · Cited by 1,273
Coupled electrophysiological, hemodynamic, and cerebrospinal fluid oscillations in human sleep
Fultz, N. E., Bonmassar, G., Setsompop, K., Stickgold, R. A., Rosen, B. R., Polimeni, J. R., & Lewis, L. D. (2019) · Science · doi:10.1126/science.aax5440 · Cited by 1,197
Self-citationThe Human Connectome Project's neuroimaging approach
Glasser, M. F., Smith, S. M., Marcus, D. S., Andersson, J. L. R., Auerbach, E. J., Behrens, T. E. J., Coalson, T. S., Harms, M. P., Jenkinson, M., Moeller, S., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4361 · Cited by 1,090
Image processing and analysis methods for the Adolescent Brain Cognitive Development Study
Hagler, D. J., Hatton, S. N., Cornejo, M. D., Makowski, C., Fair, D. A., Dick, A. S., Sutherland, M. T., Casey, B. J., Barch, D. M., Harms, M. P., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116091 · Cited by 1,093
Self-citationFunctional connectomics from resting-state fMRI
Smith, S. M., Vidaurre, D., Beckmann, C. F., Glasser, M. F., Jenkinson, M., Miller, K. L., Nichols, T. E., Robinson, E. C., Salimi-Khorshidi, G., Woolrich, M. W., et al. (2013) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2013.09.016 · Cited by 952
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 889
Andersson, J., Graham, M. S., Zsoldos, E., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.058 · Cited by 752
Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI
Kundu, P., Inati, S., Evans, J. W., Luh, W., & Bandettini, P. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.028 · Cited by 637
Braga, R. M., & Buckner, R. L. (2017) · Neuron · doi:10.1016/j.neuron.2017.06.038 · Cited by 602
A somato-cognitive action network alternates with effector regions in motor cortex
Gordon, E. M., Chauvin, R. J., Van, A. N., Rajesh, A., Nielsen, A. N., Newbold, D. J., Lynch, C. J., Seider, N. A., Krimmel, S. R., Scheidter, K. M., et al. (2023) · Nature · doi:10.1038/s41586-023-05964-2 · Cited by 687
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiß, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 586
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Self-citationSimultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 544
Evaluation of slice accelerations using multiband echo planar imaging at 3T
Xu, J., Moeller, S., Auerbach, E. J., Strupp, J., Smith, S. M., Feinberg, D. A., Yacoub, E. S., & Uǧurbil, K. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.055 · Cited by 526
Functional gradients of the cerebellum
Guell, X., Schmahmann, J. D., Gabrieli, J. D., & Ghosh, S. S. (2018) · eLife · doi:10.7554/elife.36652 · Cited by 472
Guell, X., Gabrieli, J. D. E., & Schmahmann, J. D. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.082 · Cited by 476
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
Feinberg, D. A., & Setsompop, K. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.002 · Cited by 442
Self-citationIntegrated strategy for improving functional connectivity mapping using multiecho fMRI
Kundu, P., Brenowitz, N. D., Voon, V., Worbe, Y., Vértes, P. E., Inati, S. J., Saad, Z. S., Bandettini, P. A., & Bullmore, E. T. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301725110 · Cited by 399
Akçakaya, M., Moeller, S., Weingärtner, S., & Uǧurbil, K. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 394
Andersson, J., Graham, M. S., Drobnjak, I., Zhang, H. G., Filippini, N., & Bastiani, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.085 · Cited by 382
Multisite functional connectivity MRI classification of autism: ABIDE results
Nielsen, J. A., Zielinski, B. A., Fletcher, P. T., Alexander, A. L., Lange, N., Bigler, E. D., Lainhart, J. E., & Anderson, J. S. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00599 · Cited by 377
Babayan, A., Erbey, M., Kumral, D., Reinelt, J. D., Reiter, A. M. F., Röbbig, J., Schaare, H. L., Uhlig, M., Anwander, A., Bazin, P., et al. (2019) · Scientific Data · doi:10.1038/sdata.2018.308 · Cited by 379
A wavelet method for modeling and despiking motion artifacts from resting-state fMRI time series
Patel, A. X., Kundu, P., Rubinov, M., Jones, P. S., Vértes, P. E., Ersche, K. D., John Suckling, A., & Bullmore, E. T. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.03.012 · Cited by 354
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
Setsompop, K., Cohen‐Adad, J., Gagoski, B. A., Raij, T., Yendiki, A., Keil, B. R., Wedeen, V. J., & Wald, L. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.033 · Cited by 357
Self-citationAlves, P. N., Foulon, C., Karolis, V., Bzdok, D., Margulies, D. S., Volle, E., & Thiebaut de Schotten, M. (2019) · Communications Biology · doi:10.1038/s42003-019-0611-3 · Cited by 357
Multi-compartment microscopic diffusion imaging
Kaden, E., Kelm, N. D., Carson, R. P., Does, M. D., & Alexander, D. C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.002 · Cited by 345
Capturing the spatiotemporal dynamics of self-generated, task-initiated thoughts with EEG and fMRI
Bréchet, L., Brunet, D., Birot, G., Rolf Gruetter, A., Michel, C. M., & Jorge, J. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.029 · Cited by 339
A dedicated neonatal brain imaging system
Hughes, E., Winchman, T., Padormo, F., Teixeira, R. P. A. G., Wurie, J., Sharma, M., Fox, M. J., Hutter, J. M., Cordero‐Grande, L., Price, A. N., et al. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26462 · Cited by 324
Studying neuroanatomy using MRI
Lerch, J. P., van der Kouwe, A. J. W., Raznahan, A., Paus, T., Johansen‐Berg, H., Miller, K. L., Smith, S. M., Fischl, B. R., & Sotiropoulos, S. N. (2017) · Nature Neuroscience · doi:10.1038/nn.4501 · Cited by 330
The Human Connectome Project: A retrospective
Elam, J. S., Glasser, M. F., Harms, M. P., Sotiropoulos, S. N., Andersson, J., Burgess, G. C., Curtiss, S. W., Oostenveld, R., Larson‐Prior, L. J., Schoffelen, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118543 · Cited by 340
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L., Helms, G., Mohammadi, S., & Kirilina, E. P. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 321
In vivo histology of the myelin g-ratio with magnetic resonance imaging
Stikov, N., Campbell, J. S. W., Stroh, T., Lavelée, M., Frey, S., Novek, J., Nuara, S. G., Ho, M., Bedell, B. J., Dougherty, R. F., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.023 · Cited by 306
Building connectomes using diffusion MRI: why, how and but
Sotiropoulos, S. N., & Zalesky, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3752 · Cited by 290
A 64‐channel 3T array coil for accelerated brain MRI
Keil, B. R., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260
Self-citationInterslice leakage artifact reduction technique for simultaneous multislice acquisitions
Cauley, S., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24898 · Cited by 257
Self-citationMGH–USC Human Connectome Project datasets with ultra-high b-value diffusion MRI
Fan, Q., Witzel, T., Nummenmaa, A. R., Dijk, K. R. A. V., Horn, J. D. V., Drews, M. K., Somerville, L. H., Sheridan, M. A., Santillana, R. M., Snyder, J., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.075 · Cited by 252
Self-citationRecent advances in parallel imaging for MRI
Hamilton, J., Franson, D. N., & Seiberlich, N. (2017) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2017.04.002 · Cited by 269
Yeo, B. T. T., Krienen, F. M., Chee, M. W. L., & Buckner, R. L. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.046 · Cited by 247
Quantitative mapping of the per‐axon diffusion coefficients in brain white matter
Kaden, E., Kruggel, F., & Alexander, D. C. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25734 · Cited by 243
Prospective representation of navigational goals in the human hippocampus
Brown, T. I., Carr, V. A., LaRocque, K. F., Favila, S. E., Gordon, A. M., Bowles, B., Bailenson, J. N., & Wagner, A. D. (2016) · Science · doi:10.1126/science.aaf0784 · Cited by 233
Wave‐CAIPI for highly accelerated 3D imaging
Bilgiç, B., Gagoski, B. A., Cauley, S., Fan, A. P., Polimeni, J. R., Grant, P. E., Wald, L. L., & Setsompop, K. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25347 · Cited by 236
Self-citationPhysiological Noise in Brainstem fMRI
Brooks, J. C. W., Harrison, O. K., Pattinson, K. T. S., & Jenkinson, M. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00623 · Cited by 227
Braga, R. M., DiNicola, L. M., Becker, H. C., & Buckner, R. L. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00753.2019 · Cited by 221
High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project
Vu, A. T., Auerbach, E. J., Lenglet, C., Moeller, S., Sotiropoulos, S. N., Jbabdi, S., Andersson, J., Yacoub, E. S., & Uǧurbil, K. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.004 · Cited by 222
Parallel distributed networks dissociate episodic and social functions within the individual
DiNicola, L. M., Braga, R. M., & Buckner, R. L. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00529.2019 · Cited by 230
Functional Magnetic Resonance Imaging Methods
Chen, J. E., & Glover, G. H. (2015) · Neuropsychology Review · doi:10.1007/s11065-015-9294-9 · Cited by 249
Modelling white matter with spherical deconvolution: How and why?
Dell’Acqua, F., & Tournier, J. (2018) · NMR in Biomedicine · doi:10.1002/nbm.3945 · Cited by 223
Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla
Feinberg, D. A., Beckett, A. J. S., Vu, A. T., Stockmann, J., Huber, L., Ma, S. J., Ahn, S., Setsompop, K., Cao, X., Park, S., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02068-7 · Cited by 201
Self-citationThe future of the human connectome
Essen, D. C. V., & Uǧurbil, K. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.032 · Cited by 197
Key clinical benefits of neuroimaging at 7 T
Trattnig, S., Springer, E., Bogner, W., Hangel, G. J., Strasser, B., Dymerska, B., Cardoso, P. L., & Robinson, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.031 · Cited by 183
Fast fMRI can detect oscillatory neural activity in humans
Lewis, L. D., Setsompop, K., Rosen, B. R., & Polimeni, J. R. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608117113 · Cited by 198
Self-citationSotiropoulos, S. N., Moeller, S., Jbabdi, S., Xu, J., Andersson, J., Auerbach, E. J., Yacoub, E. S., Feinberg, D. A., Setsompop, K., Wald, L. L., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24623 · Cited by 192
Self-citationAdvances in resting state fMRI acquisitions for functional connectomics
Raimondo, L., de Oliveira, I. A. F., Heij, J., Priovoulos, N., Kundu, P., Leoni, R. F., & van der Zwaag, W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118503 · Cited by 188
Huang, S. Y., Witzel, T., Keil, B. R., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., KIRSCH, J. E., Yendiki, A., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118530 · Cited by 186
Self-citationHernández-Fernández, M., Reguly, I. Z., Jbabdi, S., Giles, M. B., Smith, S. M., & Sotiropoulos, S. N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.12.015 · Cited by 182
Kodiweera, C., Alexander, A. L., Harezlak, J., McAllister, T. W., & Wu, Y.-C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.033 · Cited by 179
Setsompop, K., Fan, Q., Stockmann, J., Bilgiç, B., Huang, S. Y., Cauley, S., Nummenmaa, A. R., Wang, F., Yogesh Rathi, A., Witzel, T., et al. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26653 · Cited by 174
Self-citationMassively parallel MRI detector arrays
Keil, B. R., & Wald, L. L. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.001 · Cited by 184
Self-citationMagnetic Resonance Imaging at Ultrahigh Fields
Uǧurbil, K. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2313619 · Cited by 182
Todd, N., Moeller, S., Auerbach, E. J., Yacoub, E. S., Flandin, G., & Weiskopf, N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.056 · Cited by 177
Imaging at ultrahigh magnetic fields: History, challenges, and solutions
Uǧurbil, K. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 175
Locus Coeruleus Activity Mediates Hyperresponsiveness in Posttraumatic Stress Disorder
Naegeli, C., Zeffiro, T. A., Piccirelli, M., Jaillard, A. S., Weilenmann, A., Hassanpour, K., Schick, M., Rufer, M., Orr, S. P., & Mueller‐Pfeiffer, C. (2017) · Biological Psychiatry · doi:10.1016/j.biopsych.2017.08.021 · Cited by 184
Tradeoffs in pushing the spatial resolution of fMRI for the 7T Human Connectome Project
Vu, A. T., Jamison, K. W., Glasser, M. F., Smith, S. M., Coalson, T. S., Moeller, S., Auerbach, E. J., Uǧurbil, K., & Yacoub, E. S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.049 · Cited by 156
Functional Evidence for a Cerebellar Node of the Dorsal Attention Network
Brissenden, J. A., Levin, E. J., Osher, D. E., Halko, M. A., & Somers, D. C. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.0344-16.2016 · Cited by 163
Braga, R. M., Van Dijk, K. R. A., Polimeni, J. R., Eldaief, M. C., & Buckner, R. L. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00808.2018 · Cited by 162
Self-citationShah, L. M., Cramer, J. A., Ferguson, M. A., Birn, R. M., & Anderson, J. S. (2016) · Brain and Behavior · doi:10.1002/brb3.456 · Cited by 150
Image formation in diffusion MRI: A review of recent technical developments
Wu, W., & Miller, K. L. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25664 · Cited by 147
Moeller, S., Pisharady, P. K., Ramanna, S., Lenglet, C., Wu, X., Dowdle, L. T., Yacoub, E. S., Uǧurbil, K., & Akçakaya, M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117539 · Cited by 148
Auerbach, E. J., Xu, J., Yacoub, E. S., Moeller, S., & Uǧurbil, K. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24719 · Cited by 144
Robinson, S., Bredies, K., Khabipova, D., Dymerska, B., Marques, J. P., & Schweser, F. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3601 · Cited by 144
Chen, L., Beckett, A. J. S., Verma, A., & Feinberg, D. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.073 · Cited by 139
Xue, A., Kong, R., Yang, Q., Eldaief, M. C., Angeli, P. A., DiNicola, L. M., Braga, R. M., Buckner, R. L., & Yeo, B. T. T. (2020) · Journal of Neurophysiology · doi:10.1152/jn.00561.2020 · Cited by 151
Polimeni, J. R., Bhat, H., Witzel, T., Benner, T., Feiweier, T., Inati, S., Renvall, V., Heberlein, K., & Wald, L. L. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25628 · Cited by 140
Self-citationConnectome imaging for mapping human brain pathways
Shi, Y., & Toga, A. W. (2017) · Molecular Psychiatry · doi:10.1038/mp.2017.92 · Cited by 135
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Analysis strategies for high-resolution UHF-fMRI data
Polimeni, J. R., Renvall, V., Zaretskaya, N., & Fischl, B. R. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.053 · Cited by 129
Self-citationImage quality transfer and applications in diffusion MRI
Alexander, D. C., Zikic, D., Ghosh, A., Tanno, R., Wottschel, V., Zhang, J., Kaden, E., Dyrby, T. B., Sotiropoulos, S. N., Zhang, H. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.089 · Cited by 131
A high-impedance detector-array glove for magnetic resonance imaging of the hand
Zhang, B., Sodickson, D. K., & Cloos, M. A. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0233-y · Cited by 130
Echo planar time‐resolved imaging (EPTI)
Wang, F., Dong, Z., Reese, T. G., Bilgiç, B., Manhard, M. K., Chen, J. E., Polimeni, J. R., Wald, L. L., & Setsompop, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27673 · Cited by 130
Self-citationGrèzes, J., Valabrègue, R., Gholipour, B., & Chevallier, C. (2014) · Human Brain Mapping · doi:10.1002/hbm.22598 · Cited by 139
Validation of tractography: Comparison with manganese tracing
Knösche, T. R., Anwander, A., Liptrot, M., & Dyrby, T. B. (2015) · Human Brain Mapping · doi:10.1002/hbm.22902 · Cited by 127
The white matter tracts of the cerebrum in ventricular surgery and hydrocephalus
Güngör, A., Baydın, S. Ş., Middlebrooks, E. H., Tanrıöver, N., İşler, C., & Rhoton, A. L. (2016) · Journal of neurosurgery · doi:10.3171/2016.1.jns152082 · Cited by 132
Heidemann, R. M., Anwander, A., Feiweier, T., Knösche, T. R., & Turner, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.12.081 · Cited by 125
A Template and Probabilistic Atlas of the Human Sensorimotor Tracts using Diffusion MRI
Archer, D. B., Vaillancourt, D. E., & Coombes, S. A. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx066 · Cited by 121
Evaluation of highly accelerated simultaneous multi-slice EPI for fMRI
Chen, L., Vu, A. T., Xu, J., Moeller, S., Uǧurbil, K., Yacoub, E. S., & Feinberg, D. A. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.10.027 · Cited by 125
Huber, L., Ivanov, D., Handwerker, D. A., Marrett, S., Guidi, M., Uludaǧ, K., Bandettini, P. A., & Poser, B. A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.039 · Cited by 123
The rapid development of high speed, resolution and precision in fMRI
Feinberg, D. A., & Yacoub, E. S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.049 · Cited by 126
The impact of ultra-high field MRI on cognitive and computational neuroimaging
Martino, F. D., Yacoub, E. S., Kemper, V. G., Moerel, M., Uludaǧ, K., Weerd, P. D., Uǧurbil, K., Goebel, R., & Formisano, E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.060 · Cited by 125
Real diffusion-weighted MRI enabling true signal averaging and increased diffusion contrast
Eichner, C., Cauley, S., Cohen‐Adad, J., Möller, H. E., Turner, R., Setsompop, K., & Wald, L. L. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.074 · Cited by 113
Self-citationSparse Reconstruction Techniques in Magnetic Resonance Imaging
Yang, A. C., Kretzler, M. E., Sudarski, S., Gulani, V., & Seiberlich, N. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000274 · Cited by 117
Peripheral nerve diffusion tensor imaging: Overview, pitfalls, and future directions
Jeon, T., Fung, M., Koch, K. M., Tan, E. T., & Sneag, D. B. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25876 · Cited by 117
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Accurate modeling of temporal correlations in rapidly sampled fMRI time series
Corbin, N., Todd, N., Friston, K. J., & Callaghan, M. F. (2018) · Human Brain Mapping · doi:10.1002/hbm.24218 · Cited by 116
Ernst, T., Brol, A. E., Gratz, M., Ritter, C., Bingel, U., Schlamann, M. U., Maderwald, S., Quick, H. H., Merz, C. J., & Timmann, D. (2019) · eLife · doi:10.7554/elife.46831 · Cited by 124
Metadata
- Authors
- Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L.
- Affiliations
- Harvard University (US)
- Massachusetts Institute of Technology (US)
- Massachusetts General Hospital (US)
- Corresponding author
- Setsompop, Kawin
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-08-19
- Volume
- 67
- Issue
- 5
- Pages
- 1210-1224
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- PMC
- PMC3323676
- OpenAlex
- W2053759320
- Cited by
- 1,285
- References
- 30
- Citations by year
- 2026: 65 · 2025: 89 · 2024: 79 · 2023: 74 · 2022: 102 · 2021: 121 · 2020: 110 · 2019: 133 · 2018: 122 · 2017: 118 · 2016: 89 · 2015: 76 · 2014: 44 · 2013: 45 · 2012: 14
- FWCI
- 25.71
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Magnetic Resonance in Medicine (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- 16 National Institutes of Health Institutes and Centers that support the NIH Blueprint for Neuroscience (K99EB012107, R01EB006847, R01EB007942 (NIH NIBIB grants), P41RR14075 (NCRR grant))
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- parallel imaging, phase encoding, aliasing, functional MRI, spin-echo EPI, gradient-echo EPI
- MeSH terms
- Algorithms, Brain, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Pattern Recognition, Automated, Sensitivity and Specificity, Signal Processing, Computer-Assisted, Reproducibility of Results, Artifacts, Echo-Planar Imaging, Imaging, Three-Dimensional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review