One component? Two components? Three? The effect of including a nonexchanging “free” water component in multicomponent driven equilibrium single pulse observation of T1 and T2
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Quantitative myelin content imaging provides novel and pertinent information related to underlying pathogenetic mechanisms of myelin‐related disease or disorders arising from aberrant connectivity. Multicomponent driven equilibrium single pulse observation of T1 and T2 is a time‐efficient multicomponent relaxation analysis technique that provides estimates of the myelin water fraction, a surrogate measure of myelin volume. Unfortunately, multicomponent driven equilibrium single pulse observation of T1 and T2 relies on a two water‐pool model (myelin‐associated water and intra/extracellular water), which is inadequate within partial volume voxels, i.e., containing brain tissue and ventricle or meninges, resulting in myelin water fraction underestimation. To address this, a third, nonexchanging “free‐water” component was introduced to the multicomponent driven equilibrium single pulse observation of T1 and T2 model. Numerical simulations and experimental in vivo data show that the model to perform advantageously within partial volume regions while providing robust and reproducible results. It is concluded that this model is preferable for future studies and analysis. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mapping Infant Brain Myelination with Magnetic Resonance Imaging
Deoni, S. C. L., Mercure, E., Blasi, A., Gasston, D., Thomson, A., Johnson, M., Williams, S. C. R., & Murphy, D. G. M. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2106-10.2011 · Cited by 497 · cited 1×
“mcDESPOT is a potentially rapid and whole-brain quantitative multicomponent analysis of relaxation data technique that may offer new opportunities for investigating the etiology and pathology of these disorders as well as normative development (17).”
BackgroundSelf-citationMyelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489
On the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Kolind, S. H., Laule, C., Vavasour, I. M., Li, D. K. B., Traboulsee, A. L., Mädler, B., Moore, G. R. W., & MacKay, A. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.033 · Cited by 44 · cited 1×
“Stochastic region contraction comprises the following six steps: (1) likely value ranges for each free-parameter are first defined; (2) NS potential solution sets are then generated by randomly selecting values for each free-parameter from the defined ranges; (3) the least-squares residual for each potential solution…”
BackgroundSelf-citation
Cited by
Dubois, J., Dehaene-Lambertz, G., Kulikova, S., Poupon, C., Hüppi, P. S., & Hertz-Pannier, L. (2014) · Neuroscience · doi:10.1016/j.neuroscience.2013.12.044 · Cited by 851
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Breastfeeding and early white matter development: A cross-sectional study
Deoni, S. C. L., Dean, D. C., Piryatinsky, I., O'Muircheartaigh, J., Waskiewicz, N., Lehman, K., Han, M., & Dirks, H. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.090 · Cited by 283
Self-citationDean, D. C., Jerskey, B. A., Chen, K., Protas, H., Thiyyagura, P., Roontiva, A., O'Muircheartaigh, J., Dirks, H., Waskiewicz, N., Lehman, K., et al. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2013.4544 · Cited by 263
Self-citation
Metadata
- Authors
- Deoni, S. C. L., Matthews, L., & Kolind, S. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-08-22
- Volume
- 70
- Issue
- 1
- Pages
- 147-154
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1993501415
- Cited by
- 144
- References
- 4
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: One component? Two components? Three? The effect of including a nonexchanging “free” water component in multicomponent driven equilibrium single pulse observation of T1 and T2. https://app.cochat.ai/papers/10.1002/mrm.24429
- The paper
- Deoni, S. C. L., Matthews, L., & Kolind, S. H. (2013). One component? Two components? Three? The effect of including a nonexchanging “free” water component in multicomponent driven equilibrium single pulse observation of T1 and T2. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24429
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.