The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability
Open accessAbstract
Purpose: To develop arrhythmia‐insensitive inversion recovery sequences for improved visualization of myocardial scar and quantification of diffuse fibrosis. Methods: A novel preparation pre‐pulse, called saturation pulse prepared heart‐rate‐independent inversion recovery, is introduced, which consists of a combination of saturation and inversion pulses to remove the magnetization history in each heartbeat in late gadolinium enhancement (LGE) imaging and eliminate the need for rest periods in T1 mapping. The proposed LGE and T1 mapping sequences were evaluated against conventional LGE and modified Look‐Locker inversion sequences using numerical simulations, phantom and imaging in healthy subjects and patients with suspected or known cardiovascular disease. Results: Simulations and phantom experiments show that the saturation pulse prepared heart‐rate‐independent inversion recovery pre‐pulse in LGE reduces ghosting artifacts and results in perfect nulling of the healthy myocardium in the presence of arrhythmia. In T1 mapping, saturation pulse prepared heart‐rate‐independent inversion recovery results in (a) reduced scan time (17 vs. 9 heartbeats), (b) insensitivity to heart rate for long T1, and (c) increased signal homogeneity for short T1. LGE images in a patient in atrial fibrillation during the scan show improved myocardial nulling. In vivo T1 maps demonstrate increased signal homogeneity in blood pools and myocardium. Conclusion: The proposed sequences are insensitive to heart rate variability, yield improved LGE images in the presence of arrhythmias, as well as T1 mapping with shorter scan times. Magn Reson Med 71:1024–1034, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Cited by
Messroghli, D. R., Moon, J. C., Ferreira, V. M., Grosse-Wortmann, L., He, T., Kellman, P., Mascherbauer, J., Nezafat, R., Salerno, M., Schelbert, E. B., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0389-8 · Cited by 1,727
Self-citationCardiac T1 Mapping and Extracellular Volume (ECV) in clinical practice: a comprehensive review
Haaf, P., Garg, P., Messroghli, D. R., Broadbent, D. A., Greenwood, J. P., & Plein, S. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0308-4 · Cited by 959
T1-mapping in the heart: accuracy and precision
Kellman, P., & Hansen, M. S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-2 · Cited by 764
Akçakaya, M., Moeller, S., Weingärtner, S., & Uğurbil, K. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27420 · Cited by 391
Self-citationRoujol, S., Weingärtner, S., Foppa, M., Chow, K., Kawaji, K., Ngo, L. H., Kellman, P., Manning, W. J., Thompson, R. B., & Nezafat, R. (2014) · Radiology · doi:10.1148/radiol.14140296 · Cited by 317
Self-citation
Metadata
- Authors
- Weingärtner, S., Akçakaya, M., Basha, T., Kissinger, K. V., Goddu, B., Berg, S., Manning, W. J., & Nezafat, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-05-06
- Volume
- 71
- Issue
- 3
- Pages
- 1024-1034
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1941558189
- Cited by
- 177
- References
- 2
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability. https://app.cochat.ai/papers/10.1002/mrm.24761
- The paper
- Weingärtner, S., Akçakaya, M., Basha, T., Kissinger, K. V., Goddu, B., Berg, S., Manning, W. J., & Nezafat, R. (2014). Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24761
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.