The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Background field removal using spherical mean value filtering and Tikhonov regularization
Abstract
Purpose: To introduce a new method for removing background artifacts in field maps and apply it to enhance the accuracy of susceptibility mapping. Methods: A field artifact removal method is introduced that is based on the sophisticated harmonic artifact reduction for phase data (SHARP) method exploiting the harmonic mean value property. The new method uses Tikhonov regularization at the deconvolution stage and is referred to as regularization enabled SHARP (RESHARP). RESHARP was compared with SHARP in a field‐forward susceptibility simulation and in human brain experiments, considering effects on both field maps and the resulting susceptibility maps. Results: From the simulation, RESHARP was able to reduce error in the field map by 17.4% as compared with SHARP, resulting in a more accurate single‐angle susceptibility map with 6.5% relative error (compared with 48.5% using SHARP). Using RESHARP in vivo, field and susceptibility maps of the brain displayed fewer artifacts particularly at the brain boundaries, and susceptibility measurements of iron‐rich deep gray matter were also more consistent than SHARP across healthy subjects of similar age. Conclusion: Compared with SHARP, RESHARP removes background field artifact more effectively, leading to more accurate susceptibility measurements in iron‐rich deep gray matter. Magn Reson Med 71:1151–1157, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Wei, H., Dibb, R., Zhou, Y., Sun, Y., Xu, J., Wang, N., & Liu, C. (2015) · NMR in Biomedicine · doi:10.1002/nbm.3383 · Cited by 277
Glymphatic system impairment in multiple sclerosis: relation with brain damage and disability
Carotenuto, A., Cacciaguerra, L., Pagani, E., Preziosa, P., Filippi, M., & Rocca, M. A. (2022) · Brain · doi:10.1093/brain/awab454 · Cited by 275
Metadata
- Authors
- Sun, H., & Wilman, A. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-05-10
- Volume
- 71
- Issue
- 3
- Pages
- 1151-1157
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1863797586
- Cited by
- 185
- References
- 5
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Background field removal using spherical mean value filtering and Tikhonov regularization. https://app.cochat.ai/papers/10.1002/mrm.24765
- The paper
- Sun, H., & Wilman, A. H. (2014). Background field removal using spherical mean value filtering and Tikhonov regularization. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24765
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.