The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Streaking artifact reduction for quantitative susceptibility mapping of sources with large dynamic range
Open accessAbstract
Quantitative susceptibility mapping (QSM) is a novel MRI technique for the measurement of tissue magnetic susceptibility in three dimensions. Although numerous algorithms have been developed to solve this ill‐posed inverse problem, the estimation of susceptibility maps with a wide range of values is still problematic. In cases such as large veins, contrast agent uptake and intracranial hemorrhages, extreme susceptibility values in focal areas cause severe streaking artifacts. To enable the reduction of these artifacts, whilst preserving subtle susceptibility contrast, a two‐level QSM reconstruction algorithm (streaking artifact reduction for QSM, STAR‐QSM) was developed in this study by tuning a regularization parameter to automatically reconstruct both large and small susceptibility values. Compared with current state‐of‐the‐art QSM methods, such as the improved sparse linear equation and least‐squares (iLSQR) algorithm, STAR‐QSM significantly reduced the streaking artifacts, whilst preserving the sharp boundaries for blood vessels of mouse brains in vivo and fine anatomical details of high‐resolution mouse brains ex vivo. Brain image data from patients with cerebral hematoma and multiple sclerosis further illustrated the superiority of this method in reducing streaking artifacts caused by large susceptibility sources, whilst maintaining sharp anatomical details. STAR‐QSM is implemented in STI Suite, a comprehensive shareware for susceptibility imaging and quantification. Copyright © 2015 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Sparse Reconstruction by Separable Approximation
Wright, S. J., Nowak, R. D., & Figueiredo, M. A. T. (2009) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2009.2016892 · Cited by 1,854
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition
Li, W., Wu, B., & Liu, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.088 · Cited by 624
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
MRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping
Bilgic, B., Pfefferbaum, A., Rohlfing, T., Sullivan, E. V., & Adalsteinsson, E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.077 · Cited by 499
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Cited by
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Wang, Y., Spincemaille, P., Liu, Z., Dimov, A., Deh, K., Li, J., Zhang, Y., Yao, Y., Gillen, K. M., Wilman, A. H., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25693 · Cited by 273
Kim, E., Di Censo, D., Baraldo, M., Simmons, C., Rosa, I., Randall, K., Ballard, C., Dickie, B. R., Williams, S. C. R., Killick, R., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-91899-5 · Cited by 15
Metadata
- Authors
- Wei, H., Dibb, R., Zhou, Y., Sun, Y., Xu, J., Wang, N., & Liu, C.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2015-08-27
- Volume
- 28
- Issue
- 10
- Pages
- 1294-1303
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W1841022102
- Cited by
- 277
- References
- 37
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Streaking artifact reduction for quantitative susceptibility mapping of sources with large dynamic range. https://app.cochat.ai/papers/10.1002/nbm.3383
- The paper
- Wei, H., Dibb, R., Zhou, Y., Sun, Y., Xu, J., Wang, N., & Liu, C. (2015). Streaking artifact reduction for quantitative susceptibility mapping of sources with large dynamic range. NMR in Biomedicine. https://doi.org/10.1002/nbm.3383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.