Slice accelerated diffusion‐weighted imaging at ultra‐high field strength
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: Diffusion magnetic resonance imaging (dMRI) data with very high isotropic resolution can be obtained at 7T. However, for extensive brain coverage, a large number of slices is required, resulting in long acquisition times (TAs). Recording multiple slices simultaneously (SMS) promises to reduce the TA. Methods: A combination of zoomed and parallel imaging is used to achieve high isotropic resolution dMRI data with a low level of distortions at 7T. The blipped‐CAIPI (controlled aliasing in parallel imaging) approach is used to acquire several slices simultaneously. Due to their high radiofrequency (RF) power deposition and ensuing specific absorption rate (SAR) constraints, the commonly used multiband (MB) RF pulses for SMS imaging are inefficient at 7T and entail long repetition times, counteracting the usefulness of SMS acquisitions. To address this issue, low SAR multislice Power Independent of Number of Slices RF pulses are employed. Results: In vivo dMRI results with and without SMS acceleration are presented at different isotropic spatial resolutions at ultra high field strength. The datasets are recorded at a high angular resolution to detect fiber crossings. Conclusion: From the results and compared with earlier studies at these resolutions, it can be seen that scan time is significantly reduced, while image quality is preserved. Magn Reson Med 71:1518–1525, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586 · cited 2×
“(3) does not make use of the additional shift of the aliased images.”
BackgroundMethodMultiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296 · cited 1×
“Finally, multiplexed EPI has also been proposed, which combines parallel imaging-based SMS acquisition with SIR imaging (12).”
MethodSetsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285 · cited 3×
“A higher coil sensitivity variation at 7T additionally lowers g-factor penalty for SMS (8) and in-plane acceleration to an even better performance of temporal SNR.”
BackgroundMethodSelf-citation
Cited by
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Self-citationStudying neuroanatomy using MRI
Lerch, J. P., van der Kouwe, A. J. W., Raznahan, A., Paus, T., Johansen-Berg, H., Miller, K. L., Smith, S. M., Fischl, B., & Sotiropoulos, S. N. (2017) · Nature Neuroscience · doi:10.1038/nn.4501 · Cited by 310
Imaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“High resolution dMRI studies at 7 T prior to the HCP utilized partial-brain coverage (Heidemann et al., 2012a, 2012b; Eichner et al., 2014a; Eichner et al., 2014b; Strotmann et al., 2014) combining inplane parallel imaging methods with outer-volume suppression (OVS) in order to shorten the EPI echo…”
MethodAdvanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
Self-citationClinically feasible NODDI characterization of glioma using multiband EPI at 7 T
Wen, Q., Kelley, D. A. C., Banerjee, S., Lupo, J. M., Chang, S. M., Xu, D., Hess, C. P., & Nelson, S. J. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.08.017 · Cited by 88
“Advanced RF pulse design techniques have been reported to lower the peak RF power at ultra high field (Eichner et al., 2014; Sharma et al., 2015).”
Metadata
- Authors
- Eichner, C., Setsompop, K., Koopmans, P. J., Lützkendorf, R., Norris, D. G., Turner, R., Wald, L. L., & Heidemann, R. M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-06-24
- Volume
- 71
- Issue
- 4
- Pages
- 1518-1525
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2129819016
- Cited by
- 42
- References
- 3
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.