The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Interslice leakage artifact reduction technique for simultaneous multislice acquisitions
Open accessAbstract
PURPOSE: Controlled aliasing techniques for simultaneously acquired echo-planar imaging slices have been shown to significantly increase the temporal efficiency for both diffusion-weighted imaging and functional magnetic resonance imaging studies. The "slice-GRAPPA" (SG) method has been widely used to reconstruct such data. We investigate robust optimization techniques for SG to ensure image reconstruction accuracy through a reduction of leakage artifacts. METHODS: Split SG is proposed as an alternative kernel optimization method. The performance of Split SG is compared to standard SG using data collected on a spherical phantom and in vivo on two subjects at 3 T. Slice-accelerated and nonaccelerated data were collected for a spin-echo diffusion-weighted acquisition. Signal leakage metrics and time-series SNR were used to quantify the performance of the kernel fitting approaches. RESULTS: The Split SG optimization strategy significantly reduces leakage artifacts for both phantom and in vivo acquisitions. In addition, a significant boost in time-series SNR for in vivo diffusion-weighted acquisitions with in-plane 2× and slice 3× accelerations was observed with the Split SG approach. CONCLUSION: By minimizing the influence of leakage artifacts during the training of SG kernels, we have significantly improved reconstruction accuracy. Our robust kernel fitting strategy should enable better reconstruction accuracy and higher slice-acceleration across many applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Self-citationBreuer, F. A., Blaimer, M., Heidemann, R. M., Mueller, M. F., Griswold, M. A., & Jakob, P. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20401 · Cited by 633
A 64‐channel 3T array coil for accelerated brain MRI
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260
Self-citationJaermann, T., Crelier, G., Pruessmann, K. P., Golay, X., Netsch, T., van Muiswinkel, A. M. C., Mori, S., van Zijl, P. C. M., Valavanis, A., Kollias, S., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10707 · Cited by 209
Cited by
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534
Dopaminergic basis for signaling belief updates, but not surprise, and the link to paranoia
Nour, M. M., Dahoun, T., Schwartenbeck, P., Adams, R. A., FitzGerald, T. H. B., Coello, C., Wall, M. B., Dolan, R. J., & Howes, O. D. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1809298115 · Cited by 101
Metadata
- Authors
- Cauley, S. F., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-08-20
- Volume
- 72
- Issue
- 1
- Pages
- 93-102
- ISSN
- 0740-3194 (ISSN-L)
- OpenAlex
- W1605722113
- Cited by
- 255
- References
- 16
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interslice leakage artifact reduction technique for simultaneous multislice acquisitions. https://app.cochat.ai/papers/10.1002/mrm.24898
- The paper
- Cauley, S. F., Polimeni, J. R., Bhat, H., Wald, L. L., & Setsompop, K. (2014). Interslice leakage artifact reduction technique for simultaneous multislice acquisitions. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.