Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

A 64‐channel 3T array coil for accelerated brain MRI

Open access
Keil, Boris, Blau, James N., Biber, Stephan, Hoecht, Philipp, Tountcheva, Veneta, Setsompop, Kawin, Triantafyllou, Christina, Wald, Lawrence L.·2013·Magnetic Resonance in Medicine

Abstract

A 64‐channel brain array coil was developed and compared to a 32‐channel array constructed with the same coil former geometry to precisely isolate the benefit of the 2‐fold increase in array coil elements. The constructed coils were developed for a standard clinical 3T MRI scanner and used a contoured head‐shaped curved former around the occipital pole and tapered in at the neck to both improve sensitivity and patient comfort. Additionally, the design is a compact, split‐former design intended for robust daily use. Signal‐to‐noise ratio and noise amplification (G‐factor) for parallel imaging were quantitatively evaluated in human imaging and compared to a size and shape‐matched 32‐channel array coil. For unaccelerated imaging, the 64‐channel array provided similar signal‐to‐noise ratio in the brain center to the 32‐channel array and 1.3‐fold more signal‐to‐noise ratio in the brain cortex. Reduced noise amplification during highly parallel imaging of the 64‐channel array provided the ability to accelerate at approximately one unit higher at a given noise amplification compared to the sized‐matched 32‐channel array. For example, with a 4‐fold acceleration rate, the central brain and cortical signal‐to‐noise ratio of the 64‐channel array was 1.2‐ and 1.4‐fold higher, respectively, compared to the 32‐channel array. The characteristics of the coil are demonstrated in accelerated brain imaging. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.24427

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 260

Metadata

Authors
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2012-07-31
Volume
70
Issue
1
Pages
248-258
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2055628268
Cited by
260
References
15
FWCI
5.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 64‐channel 3T array coil for accelerated brain MRI. https://app.cochat.ai/papers/10.1002/mrm.24427
The paper
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2013). A 64‐channel 3T array coil for accelerated brain MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24427

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.