Frequency and phase drift correction of magnetic resonance spectroscopy data by spectral registration in the time domain
Open accessAbstract
Purpose: Frequency and phase drifts are a common problem in the acquisition of in vivo magnetic resonance spectroscopy (MRS) data. If not accounted for, frequency and phase drifts will result in artifactual broadening of spectral peaks, distortion of spectral lineshapes, and a reduction in signal‐to‐noise ratio (SNR). We present herein a new method for estimating and correcting frequency and phase drifts in in vivo MRS data. Methods: We used a simple method of fitting each spectral average to a reference scan (often the first average in the series) in the time domain through adjustment of frequency and phase terms. Due to the similarity with image registration, this method is referred to as “spectral registration.” Using simulated data with known frequency and phase drifts, the performance of spectral registration was compared with two existing methods at various SNR levels. Results: Spectral registration performed well in comparison with the other methods tested in terms of both frequency and phase drift estimation. Conclusions: Spectral registration provides an effective method for frequency and phase drift correction. It does not involve the collection of navigator echoes, and does not rely on any specific resonances, such as residual water or creatine, making it highly versatile. Magn Reson Med 73:44–50, 2015. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Stagg, C. J., Bestmann, S., Constantinescu, A. O., Moreno Moreno, L., Allman, C., Mekle, R., Woolrich, M., Near, J., Johansen‐Berg, H., & Rothwell, J. C. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.216978 · Cited by 401
Self-citationMekle, R., Mlynárik, V., Gambarota, G., Hergt, M., Krueger, G., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21961 · Cited by 324
A mechanism for value-guided choice based on the excitation-inhibition balance in prefrontal cortex
Jocham, G., Hunt, L. T., Near, J., & Behrens, T. E. J. (2012) · Nature Neuroscience · doi:10.1038/nn.3140 · Cited by 183
Self-citationBaseline GABA concentration and fMRI response
Donahue, M. J., Near, J., Blicher, J. U., & Jezzard, P. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.017 · Cited by 176
Self-citationReal‐time motion and B 0 corrected single voxel spectroscopy using volumetric navigators
Hess, A. T., Tisdall, M. D., Andronesi, O. C., Meintjes, E. M., & van der Kouwe, A. J. W. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22805 · Cited by 131
Waddell, K. W., Avison, M. J., Joers, J. M., & Gore, J. C. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.11.026 · Cited by 122
Near, J., Andersson, J., Maron, E., Ralf Mekle, A., Rolf Gruetter, A., Cowen, P. J., & Jezzard, P. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2960 · Cited by 91
Self-citationSubtraction artifacts and frequency (Mis‐)alignment in J‐difference GABA editing
Evans, J., Puts, N. A. J., Robson, S. E., Boy, F., McGonigle, D. J., Sumner, P., Singh, K. D., & Edden, R. A. E. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23923 · Cited by 69
Self-citationGodlewska, B. R., Yip, S. W., Near, J., Goodwin, G. M., & Cowen, P. J. (2013) · Psychopharmacology · doi:10.1007/s00213-013-3244-0 · Cited by 69
Self-citationProspective motion correction for single‐voxel 1H MR spectroscopy
Keating, B., Deng, W., Roddey, J. C., White, N. S., Dale, A. M., Stenger, V. A., & Ernst, T. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22448 · Cited by 50
Taylor, M. J., Godlewska, B. R., Near, J., Christmas, D. M., Potokar, J. P., Collier, J. D., Klenerman, P., Barnes, E. J., & Cowen, P. J. (2013) · Psychological Medicine · doi:10.1017/s0033291713001062 · Cited by 26
Self-citation
Cited by
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Simpson, R., Devenyi, G. A., Jezzard, P., Hennessy, T. J., & Near, J. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26091 · Cited by 368
Self-citationNear, J., Harris, A. D., Juchem, C., Kreis, R., Marjańska, M., Öz, G., Slotboom, J., Wilson, M., & Gasparovic, C. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4257 · Cited by 342
Self-citationBrakedal, B., Dölle, C., Riemer, F., Ma, Y., Nido, G. S., Skeie, G. O., Craven, A. R., Schwarzlmüller, T., Brekke, N., Diab, J., et al. (2022) · Cell Metabolism · doi:10.1016/j.cmet.2022.02.001 · Cited by 323
Reduced GABA and altered somatosensory function in children with autism spectrum disorder
Puts, N. A. J., Wodka, E. L., Harris, A. D., Crocetti, D., Tommerdahl, M., Mostofsky, S. H., & Edden, R. A. E. (2017) · Autism Research · doi:10.1002/aur.1691 · Cited by 265
Self-citation
Metadata
- Authors
- Near, J., Edden, R., Evans, C. J., Paquin, R., Harris, A., & Jezzard, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2014-01-16
- Volume
- 73
- Issue
- 1
- Pages
- 44-50
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1639707408
- Cited by
- 285
- References
- 12
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.