Abstract
Purpose: To study and reduce the effect of Gibbs ringing artifact on computed diffusion parameters. Methods: We reduce the ringing by extrapolating the k‐space of each diffusion weighted image beyond the measured part by selecting an adequate regularization term. We evaluate several regularization terms and tune the regularization parameter to find the best compromise between anatomical accuracy of the reconstructed image and suppression of the Gibbs artifact. Results: We demonstrate empirically and analytically that the Gibbs artifact, which is typically observed near sharp edges in magnetic resonance images, has a significant impact on the quantification of diffusion model parameters, even for infinitesimal diffusion weighting. We find the second order total generalized variation to be a good choice for the penalty term to regularize the extrapolation of the k‐space, as it provides a parsimonious representation of images, a practically full suppression of Gibbs ringing, and the absence of staircasing artifacts typical for total variation methods. Conclusions: Regularized extrapolation of the k‐space data significantly reduces truncation artifacts without compromising spatial resolution in comparison to the default option of window filtering. In particular, accuracy of estimating diffusion tensor imaging and diffusion kurtosis imaging parameters improves so much that unconstrained fits become possible. Magn Reson Med 76:301–314, 2016. © 2015 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
A First-Order Primal-Dual Algorithm for Convex Problems with Applications to Imaging
Chambolle, A., & Pock, T. (2011) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-010-0251-1 · Cited by 4,336
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488 · cited 1×
“[12] are set to 1 and 2, respectively (cf.”
BackgroundDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Twenty‐five pitfalls in the analysis of diffusion MRI data
Jones, D. K., & Cercignani, M. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1543 · Cited by 827 · cited 1×
“Representatively, the Gibbs artifact was not included in the comprehensive overview of pitfalls in dMRI processing and analysis by Jones and Cercignani (10).”
MethodUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Lu, H., Jensen, J. H., Ramani, A., & Helpern, J. A. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1020 · Cited by 420
Partial volume effect as a hidden covariate in DTI analyses
Vos, S. B., Jones, D. K., Viergever, M. A., & Leemans, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.048 · Cited by 345
Jelescu, I. O., Veraart, J., Adisetiyo, V., Milla, S. S., Novikov, D. S., & Fieremans, E. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.009 · Cited by 202
Self-citation
Cited by
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Self-citationGibbs-ringing artifact removal based on local subvoxel-shifts
Kellner, E., Dhital, B., Kiselev, V. G., & Reisert, M. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26054 · Cited by 1,478
Diffusion MRI noise mapping using random matrix theory
Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26059 · Cited by 773
Self-citationDegeneracy in model parameter estimation for multi‐compartmental diffusion in neuronal tissue
Jelescu, I. O., Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3450 · Cited by 316
Self-citationAdes-Aron, B., Veraart, J., Kochunov, P., McGuire, S., Sherman, P., Kellner, E., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.066 · Cited by 193
“It has been shown that denoising using MP-PCA returns the proxy hMi for signal magnitude (Veraart, 2016b)”
MethodSelf-citation
Metadata
- Authors
- Veraart, J., Fieremans, E., Jelescu, I. O., Knoll, F., & Novikov, D. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2015-08-10
- Volume
- 76
- Issue
- 1
- Pages
- 301-314
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2142554529
- Cited by
- 144
- References
- 12
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.