Optimal experimental design for filter exchange imaging: Apparent exchange rate measurements in the healthy brain and in intracranial tumors
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose: Filter exchange imaging (FEXI) is sensitive to the rate of diffusional water exchange, which depends, eg, on the cell membrane permeability. The aim was to optimize and analyze the ability of FEXI to infer differences in the apparent exchange rate (AXR) in the brain between two populations. Methods: A FEXI protocol was optimized for minimal measurement variance in the AXR. The AXR variance was investigated by test‐retest acquisitions in six brain regions in 18 healthy volunteers. Preoperative FEXI data and postoperative microphotos were obtained in six meningiomas and five astrocytomas. Results: Protocol optimization reduced the coefficient of variation of AXR by approximately 40%. Test‐retest AXR values were heterogeneous across normal brain regions, from 0.3 ± 0.2 s−1 in the corpus callosum to 1.8 ± 0.3 s−1 in the frontal white matter. According to analysis of statistical power, in all brain regions except one, group differences of 0.3–0.5 s−1 in the AXR can be inferred using 5 to 10 subjects per group. An AXR difference of this magnitude was observed between meningiomas (0.6 ± 0.1 s−1) and astrocytomas (1.0 ± 0.3 s−1). Conclusions: With the optimized protocol, FEXI has the ability to infer relevant differences in the AXR between two populations for small group sizes. Magn Reson Med 77:1104–1114, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Looking into the functional architecture of the brain with diffusion MRI.
Le Bihan, D. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1119 · Cited by 1,571 · cited 1×
“f 0 f ðtmÞ 1⁄4 f eq f 1⁄2f eq f f 0 f ð0Þ expð tm1⁄2ksf þ kfs Þ; [1]”
Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856 · cited 1×
“Sðb; tmÞ 1⁄4 S0ðtmÞexpð bfADCÞexpð bADC 1⁄21 s expð AXRtmÞ Þ; [4]”
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 1×
“ADCðtmÞ 1⁄4 ADC1⁄21 sexpð AXRtmÞ ; [3]”
An analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501
Cited by
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Self-citationNovikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Studying neuroanatomy using MRI
Lerch, J. P., van der Kouwe, A. J. W., Raznahan, A., Paus, T., Johansen-Berg, H., Miller, K. L., Smith, S. M., Fischl, B., & Sotiropoulos, S. N. (2017) · Nature Neuroscience · doi:10.1038/nn.4501 · Cited by 310
Design and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240
TE dependent Diffusion Imaging (TEdDI) distinguishes between compartmental T2 relaxation times
Veraart, J., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.09.030 · Cited by 212
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Sundgren, P. C., & Nilsson, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.053 · Cited by 200
Self-citationJelescu, I. O., de Skowronski, A., Geffroy, F., Palombo, M., & Novikov, D. S. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119277 · Cited by 177
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Hansson, O., Westin, C., & Nilsson, M. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28216 · Cited by 86
Self-citationLampinen, B., Szczepankiewicz, F., Lätt, J., Knutsson, L., Mårtensson, J., Björkman-Burtscher, I. M., van Westen, D., Sundgren, P. C., Ståhlberg, F., & Nilsson, M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120338 · Cited by 38
Self-citationYin, H., Lu, Z., Deng, Y., Tian, X., & Gong, Q. (2026) · Ageing Research Reviews · doi:10.1016/j.arr.2025.102952 · Cited by 6
Metadata
- Authors
- Lampinen, B., Szczepankiewicz, F., van Westen, D., Englund, E., C Sundgren, P., Lätt, J., Ståhlberg, F., & Nilsson, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2016-03-10
- Volume
- 77
- Issue
- 3
- Pages
- 1104-1114
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2294354247
- Cited by
- 97
- References
- 6
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.