CoChat

Rapid in vivo detection of rat spinal cord injury with double-diffusion-encoded magnetic resonance spectroscopy: Double-Diffusion Encoding in Spinal Cord Injury

Open access
Skinner, Nathan P., Kurpad, Shekar N., Schmit, Brian D., Tugan Muftuler, L., Budde, Matthew D. · 2017 · Magnetic Resonance in Medicine
Cited by 45

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Purpose Diffusion-weighted imaging is a common experimental tool for evaluating spinal cord injury (SCI), yet it suffers from complications that decrease its clinical effectiveness. The most commonly used technique, diffusion tensor imaging (DTI), is often confounded by effects of edema accompanying acute SCI, limiting its sensitivity to the important functional status marker of axonal integrity. The purpose of this study is to introduce a novel diffusion-acquisition method with the goal of overcoming these limitations. Methods A double diffusion encoding (DDE) pulse sequence was implemented with a diffusion-weighted filter orthogonal to the spinal cord for suppressing nonneural signals prior to diffusion weighting parallel to the cord. A point-resolved spectroscopy readout (DDE-PRESS) was used for improved sensitivity and compared with DTI in a rat model of SCI with varying injury severities. Results The DDE-PRESS parameter, restricted fraction, showed a strong relationship with injury severity (P < 0.001, R2 = 0.67). Although the whole-cord averaged DTI parameter values exhibited only minor injury relationships, a weighted region of interest (ROI) based DTI analysis improved sensitivity to injury (P < 0.001, R2 = 0.66). Conclusions In a rat model of SCI, DDE-PRESS demonstrated high sensitivity to injury with substantial decreases in acquisition time and data processing. This method shows promise for application in rapid evaluation of SCI severity. Magn Reson Med 77:1639–1649, 2017. © 2016 International Society for Magnetic Resonance in Medicine

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.26243

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 45

Metadata

Authors
Skinner, N. P., Kurpad, S. N., Schmit, B. D., Tugan Muftuler, L., & Budde, M. D.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2016-04-15
Volume
77
Issue
4
Pages
1639-1649
ISSN
0740-3194 (ISSN-L)
OpenAlex
W2337141133
Cited by
45
References
5
FWCI
5.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rapid in vivo detection of rat spinal cord injury with double-diffusion-encoded magnetic resonance spectroscopy: Double-Diffusion Encoding in Spinal Cord Injury. https://app.cochat.ai/papers/10.1002/mrm.26243
The paper
Skinner, N. P., Kurpad, S. N., Schmit, B. D., Tugan Muftuler, L., & Budde, M. D. (2017). Rapid in vivo detection of rat spinal cord injury with double-diffusion-encoded magnetic resonance spectroscopy: Double-Diffusion Encoding in Spinal Cord Injury. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.26243

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.