5D whole‐heart sparse MRI
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Purpose: A 5D whole‐heart sparse imaging framework is proposed for simultaneous assessment of myocardial function and high‐resolution cardiac and respiratory motion‐resolved whole‐heart anatomy in a single continuous noncontrast MR scan. Methods: A non–electrocardiograph (ECG)‐triggered 3D golden‐angle radial balanced steady‐state free precession sequence was used for data acquisition. The acquired 3D k‐space data were sorted into a 5D dataset containing separated cardiac and respiratory dimensions using a self‐extracted respiratory motion signal and a recorded ECG signal. Images were then reconstructed using XD‐GRASP, a multidimensional compressed sensing technique exploiting correlations/sparsity along cardiac and respiratory dimensions. 5D whole‐heart imaging was compared with respiratory motion‐corrected 3D and 4D whole‐heart imaging in nine volunteers for evaluation of the myocardium, great vessels, and coronary arteries. It was also compared with breath‐held, ECG‐gated 2D cardiac cine imaging for validation of cardiac function quantification. Results: 5D whole‐heart images received systematic higher quality scores in the myocardium, great vessels and coronary arteries. Quantitative coronary sharpness and length were always better for the 5D images. Good agreement was obtained for quantification of cardiac function compared with 2D cine imaging. Conclusion: 5D whole‐heart sparse imaging represents a robust and promising framework for simplified comprehensive cardiac MRI without the need for breath‐hold and motion correction. Magn Reson Med 79:826–838, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952 · cited 2×
“The sorted 5D whole-heart images were reconstructed using a non-linear conjugate gradient algorithm (46,47).”
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256 · cited 6×
“5D whole-heart images (end-expiratory phase) achieved improved visual delineation of the myocardial wall and different segments of the coronary arteries (white arrows) over 4D whole-heart images, and improved delineation of the LAD over self-navigated 3D whole-heart images.”
InfluentialSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Self-citationSPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Self-citationFeng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667 · cited 10×
“Images were then reconstructed using XD-GRASP, a multidimensional compressed sensing technique exploiting correlations/sparsity along cardiac and respiratory dimensions.”
InfluentialSelf-citationOtazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Self-citationCompressed sensing in dynamic MRI
Gamper, U., Boesiger, P., & Kozerke, S. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21477 · Cited by 569
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Self-citationGadgetron: An open source framework for medical image reconstruction
Hansen, M. S., & Sørensen, T. S. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24389 · Cited by 339 · cited 1×
“Moreover, different solutions, such as the Gadgetron and Yarra framework (66,67), have already been proposed towards clinical use of highly computationally demanding reconstruction techniques.”
Cardiovascular Magnetic Resonance
Pennell, D. J. (2010) · Circulation · doi:10.1161/circulationaha.108.811547 · Cited by 338
“Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms
Etienne, A., Botnar, R. M., van Muiswinkel, A. M., Boesiger, P., Manning, W. J., & Stuber, M. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10253 · Cited by 266 · cited 1×
“Soap-bubble software (52) was used for all coronary artery reformatting and quantitative measurement.”
Self-citationHighly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Self-citationLi, D., Paschal, C. B., Haacke, E. M., & Adler, L. P. (1993) · Radiology · doi:10.1148/radiology.187.2.8475281 · Cited by 224 · cited 1×
“For the coronary arteries, a 3D cardiac scan must also provide good vessel contrast, in order to discriminate arteries from surrounding epicardial fat and myocardium (3,12).”
Sakuma, H., Ichikawa, Y., Suzawa, N., Hirano, T., Makino, K., Koyama, N., CAUTEREN, M. V., & Takeda, K. (2005) · Radiology · doi:10.1148/radiol.2371040830 · Cited by 207 · cited 1×
“Free-breathing ECG-triggered and navigator-gated whole-heart MRI was performed using a 3D b-SSFP Cartesian imaging protocol described by Sakuma H et al in (44).”
Spiral phyllotaxis: The natural way to construct a 3D radial trajectory in MRI
Piccini, D., Littmann, A., Nielles‐Vallespin, S., & Zenge, M. O. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22898 · Cited by 179 · cited 2×
“The 3D radial sampling scheme, as shown in Figure 1a&b, is segmented into multiple interleaves based on the spiral phyllotaxis pattern (42), in which each interleave is rotated by the golden-angle about the zaxis with respect to the previous interleave.”
Self-citationCompressed Sensing Single–Breath-Hold CMR for Fast Quantification of LV Function, Volumes, and Mass
Vincenti, G. M., Monney, P. A., Chaptinel, J., Rutz, T., Coppo, S., Zenge, M. O., Schmidt, M., Nadar, M. S., Piccini, D., Chèvre, P., et al. (2014) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2014.04.016 · Cited by 165 · cited 2×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Self-citationFree-breathing pediatric MRI with nonrigid motion correction and acceleration
Cheng, J. Y., Zhang, T., Ruangwattanapaisarn, N., Alley, M. T., Uecker, M., Pauly, J. M., Lustig, M. S., & Vasanawala, S. S. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24785 · Cited by 161 · cited 1×
“The proposed 5D sparse cardiac imaging framework can be combined with various golden-angle sampling schemes in both radial and Cartesian trajectory (20,22,63-65).”
Piccini, D., Littmann, A., Nielles‐Vallespin, S., & Zenge, M. O. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23247 · Cited by 157 · cited 3×
“(22,25), the respiratory motion signal was extracted by performing cross-correlation on the self-navigation projection, and the resulting 1D SI displacement was then used for correcting each data interleave before image reconstruction by directly applying an angle-specific phase shift to all k-space readouts (24).”
Self-citationComprehensive Cardiac Magnetic Resonance Imaging at 3.0 Tesla
Gutberlet, M., Noeske, R., Schwinge, K., Freyhardt, P., Felix, R., & Niendorf, T. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000195840.50230.10 · Cited by 131 · cited 1×
“3D cardiac imaging can provide comprehensive information with minimum scan planning, allowing a multifaceted assessment of the cardiovascular system (8-11).”
Quantification of left ventricular function with magnetic resonance images acquired in real time
Setser, R. M., Fischer, S., & Lorenz, C. H. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200009)12:3<430::aid-jmri8>3.0.co;2-v · Cited by 122 · cited 1×
“The number of cardiac phases was selected such that the resulting temporal resolution was adequate for quantification of global cardiac function (45).”
Piccini, D., Monney, P. A., Sierro, C., Coppo, S., Bonanno, G., van Heeswijk, R. B., Chaptinel, J., Vincenti, G. M., Blois, J. D., Koestner, S. C., et al. (2013) · Radiology · doi:10.1148/radiol.13132045 · Cited by 115 · cited 1×
“Although 1D translational motion correction has been previously tested in both patient and volunteer studies in our center (25,27,43), additional comparison with other respiratory motion correction schemes, such as 3D affine or nonrigid motion correction, would be necessary to further validate the value of the propose…”
Self-citationFour-dimensional respiratory motion-resolved whole heart coronary MR angiography
Piccini, D., Feng, L., Bonanno, G., Coppo, S., Yerly, J., Lim, R., Schwitter, J., Sodickson, D. K., Otazo, R., & Stuber, M. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26221 · Cited by 105 · cited 6×
“Successful applications of XD-GRASP have been demonstrated for free-breathing liver MRI (36,38), whole-heart coronary MRA (39) and cardiac cine MRI (36,40,41).”
InfluentialSelf-citationk‐t group sparse: A method for accelerating dynamic MRI
Usman, M., Prieto, C., Schaeffter, T., & Batchelor, P. G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22883 · Cited by 104 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Coronary magnetic resonance angiography
Stuber, M., & Weiss, R. G. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20949 · Cited by 101
Self-citationWu, H. H., Gurney, P. T., Hu, B. S., Nishimura, D. G., & McConnell, M. V. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24346 · Cited by 96
Feng, L., Otazo, R., Jung, H., Jensen, J. H., Ye, J. C., Sodickson, D. K., & Kim, D. C. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22756 · Cited by 93
Self-citationBloomgarden, D. C., Fayad, Z. A., Ferrari, V. A., Chin, B. B., Sutton, M. G. S. J., & Axel, L. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370510 · Cited by 91 · cited 10×
“Magnetic resonance in medicine 2016;75(4):1594-1604.”
Influentialda Cruz, G. J. L., Atkinson, D., Buerger, C., Schaeffter, T., & Prieto, C. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25708 · Cited by 82 · cited 1×
“On the other hand, 3D motion correction and motionresolved reconstruction are complementary techniques that could be combined to further increase motion robustness (69).”
Han, F., Rapacchi, S., Khan, S. N., Ayad, I., Salusky, I. B., Gabriel, S., Plotnik, A. N., Finn, J. P., & Hu, P. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25491 · Cited by 71 · cited 3×
“4D cardiac MRI enables greatly improved scan efficiency with significantly simplified imaging workflow, allowing for assessment of cardiac function and whole-heart anatomy at different cardiac phases (20,22,23).”
Self‐navigated isotropic three‐dimensional cardiac T2 mapping
van Heeswijk, R. B., Piccini, D., Feliciano, H., Hullin, R., Schwitter, J., & Stuber, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25258 · Cited by 64 · cited 1×
“In addition to assessment of myocardial function, great vessels and the coronary arteries, the proposed 5D whole-heart MRI framework can also be extended to other cardiac MR applications such as myocardial parameter mapping (71,72) or 4D flow imaging (73).”
Self-citationMonney, P. A., Piccini, D., Rutz, T., Vincenti, G. M., Coppo, S., Koestner, S. C., Sekarski, N., Bernardo, S. D., Bouchardy, J., Stuber, M., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0156-7 · Cited by 57 · cited 1×
“Although 1D translational motion correction has been previously tested in both patient and volunteer studies in our center (25,27,43), additional comparison with other respiratory motion correction schemes, such as 3D affine or nonrigid motion correction, would be necessary to further validate the value of the propose…”
Self-citationRespiratory self‐gated four‐dimensional coronary MR angiography: A feasibility study
Lai, P., Larson, A. C., Park, J., Carr, J., & Li, D. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21617 · Cited by 51
Coronary MR angiography at 3T during diastole and systole
Gharib, A. M., Herzka, D. A., Ustun, A., Desai, M. Y., Locklin, J. K., Pettigrew, R. I., & Stuber, M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21056 · Cited by 50 · cited 1×
“During the past decade, a variety of four-dimensional (4D) cardiac MRI techniques have been proposed (13-23), where time-resolved 3D volumes are acquired covering the entire cardiac cycle.”
Self-citationWhole‐Heart Coronary MRA with 3D Affine Motion Correction Using 3D Image‐Based Navigation
Henningsson, M., Prieto, C., Chiribiri, A., Vaillant, G., Razavi, R., & Botnar, R. M. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24652 · Cited by 49 · cited 1×
“The second category aims at improving the scan efficiency by combining images at different respiratory phases using an image registration algorithm, which models the movement of heart during respiration as translation (24-29), affine (20,30-34) or non-rigid (35)”
Foo, T., Ho, V. B., Saranathan, M., Cheng, L.-Q., Sakuma, H., Kraitchman, D. L., Wu, K. C., & Bluemke, D. A. (2005) · Radiology · doi:10.1148/radiol.2353040090 · Cited by 30 · cited 2×
“JACC Cardiovasc Imaging 2014;7(9):882-892.”
Xu, J., Kim, D. J., Otazo, R., Srichai, M. B., Lim, R., Axel, L., Mcgorty, K. A., Niendorf, T., & Sodickson, D. K. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23955 · Cited by 20 · cited 3×
“Investigative radiology 2015;50(11):749756.”
Self-citationLocalized spatio‐temporal constraints for accelerated CMR perfusion
Akçakaya, M., Basha, T., Pflugi, S., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24963 · Cited by 18 · cited 1×
“Although various fast imaging approaches, such as parallel imaging (53-55) and compressed sensing (46,56,57), have been applied to accelerate cardiac MR scans (7,11,58-62), they have had relatively little impact in reducing the complexity of imaging workflow.”
Sodickson, D. K., Feng, L., Knöll, F., Cloos, M. A., Ben‐Eliezer, N., Axel, L., Chandarana, H., Block, K. T., & Otazo, R. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2085033 · Cited by 8
Self-citationGrieve (2000) · doi:10.1002/(sici)1522-2594(200005)43:5 · cited 1×
“Coil sensitivity maps were calculated using the adaptive combination approach (48) and were estimated from a 3D image volume reconstructed using all the acquired k-space data.”
Cited by
Küstner, T., Fuin, N., Hammernik, K., Bustin, A., Qi, H., Hajhosseiny, R., Masci, P. G., Neji, R., Rueckert, D., Botnar, R. M., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-70551-8 · Cited by 233
Self-citation
Metadata
- Authors
- Feng, L., Coppo, S., Piccini, D., Yerly, J., Lim, R. P., Masci, P. G., Stuber, M., Sodickson, D. K., & Otazo, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-05-11
- Volume
- 79
- Issue
- 2
- Pages
- 826-838
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2612299033
- Cited by
- 171
- References
- 42
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.