MEDI+0: Morphology enabled dipole inversion with automatic uniform cerebrospinal fluid zero reference for quantitative susceptibility mapping
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose: To develop a quantitative susceptibility mapping (QSM) method with a consistent zero reference using minimal variation in cerebrospinal fluid (CSF) susceptibility. Theory and Methods: The ventricular CSF was automatically segmented on the map. An L 2‐regularization was used to enforce CSF susceptibility homogeneity within the segmented region, with the averaged CSF susceptibility as the zero reference. This regularization for CSF homogeneity was added to the model used in a prior QSM method (morphology enabled dipole inversion [MEDI]). Therefore, the proposed method was referred to as MEDI+0 and compared with MEDI in a numerical simulation, in multiple sclerosis (MS) lesions, and in a reproducibility study in healthy subjects. Results: In both the numerical simulations and in vivo experiments, MEDI+0 not only decreased the susceptibility variation within the ventricular CSF, but also suppressed the artifact near the lateral ventricles. In the simulation, MEDI+0 also provided more accurate quantification compared to MEDI in the globus pallidus, substantia nigra, corpus callosum, and internal capsule. MEDI+0 measurements of MS lesion susceptibility were in good agreement with those obtained by MEDI. Finally, both MEDI+0 and MEDI showed good and similar intrasubject reproducibility. Conclusion: QSM with a minimal variation in ventricular CSF is viable to provide a consistent zero reference while improving image quality. Magn Reson Med 79:2795–2803, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Self-citationQuantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Self-citationQuantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
MRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping
Bilgic, B., Pfefferbaum, A., Rohlfing, T., Sullivan, E. V., & Adalsteinsson, E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.077 · Cited by 499
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Wisnieff, C., Ramanan, S., Olesik, J., Gauthier, S., Wang, Y., & Pitt, D. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25420 · Cited by 245
Self-citation
Cited by
Kaunzner, U. W., Kang, Y., Zhang, S., Morris, E., Yao, Y., Pandya, S., Hurtado Rua, S. M., Park, C., Gillen, K. M., Nguyen, T. D., et al. (2019) · Brain · doi:10.1093/brain/awy296 · Cited by 199
“Brain QSM maps with automatic uniform CSF zero reference (QSM0) (Liu et al., 2018; Yao et al., 2017) were reconstructed from multi-echo GRE data using the morphology-enabled dipole inversion (MEDI) method (de Rochefort et al.”
BackgroundMethodInfluentialSelf-citationImaging chronic active lesions in multiple sclerosis: a consensus statement
Bagnato, F., Sati, P., Hemond, C. C., Elliott, C., Gauthier, S. A., Harrison, D. M., Mainero, C., Oh, J., Pitt, D., Shinohara, R. T., et al. (2024) · Brain · doi:10.1093/brain/awae013 · Cited by 194
χ-separation: Magnetic susceptibility source separation toward iron and myelin mapping in the brain
Shin, H.-G., Lee, J., Yun, Y. H., Yoo, S. H., Jang, J., Oh, S.-H., Nam, Y., Jung, S., Kim, S., Fukunaga, M., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118371 · Cited by 171
Gillen, K. M., Mubarak, M., Nguyen, T. D., & Pitt, D. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00255 · Cited by 88
Metadata
- Authors
- Liu, Z., Spincemaille, P., Yao, Y., Zhang, Y., & Wang, Y.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2017-10-11
- Volume
- 79
- Issue
- 5
- Pages
- 2795-2803
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2763665792
- Cited by
- 218
- References
- 6
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.