Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 294

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Deep learning with domain adaptation for accelerated projection‐reconstruction MR

Open access
Han, Yoseob, Yoo, Jaejun, Kim, Hak Hee, Shin, Hee Jung, Sung, Kyunghyun, Ye, Jong Chul·2018·Magnetic Resonance in Medicine

Abstract

Purpose: The radial k‐space trajectory is a well‐established sampling trajectory used in conjunction with magnetic resonance imaging. However, the radial k‐space trajectory requires a large number of radial lines for high‐resolution reconstruction. Increasing the number of radial lines causes longer acquisition time, making it more difficult for routine clinical use. On the other hand, if we reduce the number of radial lines, streaking artifact patterns are unavoidable. To solve this problem, we propose a novel deep learning approach with domain adaptation to restore high‐resolution MR images from under‐sampled k‐space data. Methods: The proposed deep network removes the streaking artifacts from the artifact corrupted images. To address the situation given the limited available data, we propose a domain adaptation scheme that employs a pre‐trained network using a large number of X‐ray computed tomography (CT) or synthesized radial MR datasets, which is then fine‐tuned with only a few radial MR datasets. Results: The proposed method outperforms existing compressed sensing algorithms, such as the total variation and PR‐FOCUSS methods. In addition, the calculation time is several orders of magnitude faster than the total variation and PR‐FOCUSS methods. Moreover, we found that pre‐training using CT or MR data from similar organ data is more important than pre‐training using data from the same modality for different organ. Conclusion: We demonstrate the possibility of a domain‐adaptation when only a limited amount of MR data is available. The proposed method surpasses the existing compressed sensing algorithms in terms of the image quality and computation time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.27106

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 294

Metadata

Authors
Han, Y., Yoo, J., Kim, H. H., Shin, H. J., Sung, K., & Ye, J. C.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2018-02-04
Volume
80
Issue
3
Pages
1189-1205
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2605364158
Cited by
294
References
42
FWCI
28.98
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.