CoChat

Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning

Open access
Berhane, Haben, Scott, Michael, Elbaz, Mohammed, Jarvis, Kelly, McCarthy, Patrick, Carr, James, Malaisrie, Chris, Avery, Ryan, Barker, Alex J., Robinson, Joshua D., Rigsby, Cynthia K., Markl, Michael · 2020 · Magnetic Resonance in Medicine
Cited by 160

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Purpose: To generate fully automated and fast 4D‐flow MRI‐based 3D segmentations of the aorta using deep learning for reproducible quantification of aortic flow, peak velocity, and dimensions. Methods: A total of 1018 subjects with aortic 4D‐flow MRI (528 with bicuspid aortic valve, 376 with tricuspid aortic valve and aortic dilation, 114 healthy controls) comprised the data set. A convolutional neural network was trained to generate 3D aortic segmentations from 4D‐flow data. Manual segmentations served as the ground truth (N = 499 training, N = 101 validation, N = 418 testing). Dice scores, Hausdorff distance, and average symmetrical surface distance were calculated to assess performance. Aortic flow, peak velocity, and lumen dimensions were quantified at the ascending, arch, and descending aorta and compared using Bland‐Altman analysis. Interobserver variability of manual analysis was assessed on a subset of 40. Results: Convolutional neural network segmentation required 0.438 ± 0.355 seconds versus 630 ± 254 seconds for manual analysis and demonstrated excellent performance with a median Dice score of 0.951 (0.930‐0.966), Hausdorff distance of 2.80 (2.13‐4.35), and average symmetrical surface distance of 0.176 (0.119‐0.290). Excellent agreement was found for flow, peak velocity, and dimensions with low bias and limits of agreement less than 10% difference versus manual analysis. For aortic volume, limits of agreement were moderate within 16.3%. Interobserver variability (median Dice score: 0.950; Hausdorff distance: 2.45; and average symmetrical surface distance: 0.145) and convolutional neural network–based analysis (median Dice score: 0.953‐0.959; Hausdorff distance: 2.24‐2.91; and average symmetrical surface distance: 0.145‐1.98 to observers) demonstrated similar reproducibility. Conclusions: Deep learning enabled fast and automated 3D aortic segmentation from 4D‐flow MRI, demonstrating its potential for efficient clinical workflows. Future studies should investigate its utility for other vasculature and multivendor applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.28257

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

Metadata

Authors
Berhane, H., Scott, M., Elbaz, M., Jarvis, K., McCarthy, P., Carr, J., Malaisrie, C., Avery, R., Barker, A. J., Robinson, J. D., Rigsby, C. K., & Markl, M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2020-03-13
Volume
84
Issue
4
Pages
2204-2218
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W3010725820
Cited by
160
References
20
FWCI
8.76
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.