Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Purpose: To generate fully automated and fast 4D‐flow MRI‐based 3D segmentations of the aorta using deep learning for reproducible quantification of aortic flow, peak velocity, and dimensions. Methods: A total of 1018 subjects with aortic 4D‐flow MRI (528 with bicuspid aortic valve, 376 with tricuspid aortic valve and aortic dilation, 114 healthy controls) comprised the data set. A convolutional neural network was trained to generate 3D aortic segmentations from 4D‐flow data. Manual segmentations served as the ground truth (N = 499 training, N = 101 validation, N = 418 testing). Dice scores, Hausdorff distance, and average symmetrical surface distance were calculated to assess performance. Aortic flow, peak velocity, and lumen dimensions were quantified at the ascending, arch, and descending aorta and compared using Bland‐Altman analysis. Interobserver variability of manual analysis was assessed on a subset of 40. Results: Convolutional neural network segmentation required 0.438 ± 0.355 seconds versus 630 ± 254 seconds for manual analysis and demonstrated excellent performance with a median Dice score of 0.951 (0.930‐0.966), Hausdorff distance of 2.80 (2.13‐4.35), and average symmetrical surface distance of 0.176 (0.119‐0.290). Excellent agreement was found for flow, peak velocity, and dimensions with low bias and limits of agreement less than 10% difference versus manual analysis. For aortic volume, limits of agreement were moderate within 16.3%. Interobserver variability (median Dice score: 0.950; Hausdorff distance: 2.45; and average symmetrical surface distance: 0.145) and convolutional neural network–based analysis (median Dice score: 0.953‐0.959; Hausdorff distance: 2.24‐2.91; and average symmetrical surface distance: 0.145‐1.98 to observers) demonstrated similar reproducibility. Conclusions: Deep learning enabled fast and automated 3D aortic segmentation from 4D‐flow MRI, demonstrating its potential for efficient clinical workflows. Future studies should investigate its utility for other vasculature and multivendor applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Densely Connected Convolutional Networks
Huang, G., Liu, Z., Van Der Maaten, L., & Weinberger, K. Q. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.243 · Cited by 48,566
3D U-Net: Learning Dense Volumetric Segmentation from Sparse Annotation
Çiçek, Ö., Abdulkadir, A., Lienkamp, S. S., Brox, T., & Ronneberger, O. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_49 · Cited by 7,945 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialHaralock, R. M., & Shapiro, L. G. (1991) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 3,933
Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool
Taha, A. A., & Hanbury, A. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0068-x · Cited by 2,920 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
Influential4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877 · cited 1×
“All data sets underwent a standard 4D workflow 28 ; however, our workflow requires manual user inputs, which when performed poorly can result in a distortion of the flow data.”
Self-citationAn image-based modeling framework for patient-specific computational hemodynamics
Antiga, L., Piccinelli, M., Botti, L., Ene-Iordache, B., Remuzzi, A., & Steinman, D. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0420-1 · Cited by 850 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialConcomitant gradient terms in phase contrast MR: Analysis and correction
Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390218 · Cited by 547 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialNorman, B., Pedoia, V., & Majumdar, S. (2018) · Radiology · doi:10.1148/radiol.2018172322 · Cited by 419 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialLiu, F., Zhou, Z., Samsonov, A., Blankenbaker, D., Larison, W., Kanarek, A., Lian, K., Kambhampati, S., & Kijowski, R. (2018) · Radiology · doi:10.1148/radiol.2018172986 · Cited by 327 · cited 1×
“The dense blocks (Figure 2B) featured a constant convolutional channel size of 12, reducing the overall number of parameters and mitigating overfitting.”
Myerson, S. G., d'Arcy, J., Mohiaddin, R., Greenwood, J. P., Karamitsos, T. D., Francis, J. M., Banning, A. P., Christiansen, J. P., & Neubauer, S. (2012) · Circulation · doi:10.1161/circulationaha.111.083600 · Cited by 256 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
BackgroundMethodInfluentialThe Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis
Garcia, J., Barker, A. J., & Markl, M. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.10.034 · Cited by 217 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialSelf-citationKupfahl, C., Honold, M., Meinhardt, G., Vogelsberg, H., Wagner, A., Mahrholdt, H., & Sechtem, U. (2004) · Heart · doi:10.1136/hrt.2003.022376 · Cited by 167 · cited 2×
“The main findings of our study were (1) CNN-based aorta 3D segmentation was feasible in <1 second versus 630 seconds for manual 3D segmentation; (2) the CNN showed excellent performance compared with standard manual analysis (median DS = 0.”
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22199 · Cited by 166 · cited 6×
“The preprocessed 4D flow–derived 3D PCMRA was automatically center-cropped to a fixed dimension of 128 × 96 × number of slices and used as the input to the CNN.”
InfluentialSelf-citationFully automatic segmentation on prostate MR images based on cascaded fully convolution network
Zhu, Y. C., Wei, R., Gao, G., Ding, L., Zhang, X., Wang, X., & Zhang, J. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26337 · Cited by 125 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
Influentialvan Ooij, P., Powell, A. L., Potters, W. V., Carr, J., Markl, M., & Barker, A. A. J. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24959 · Cited by 122 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialSelf-citationHerment, A., Kachenoura, N., Lefort, M., Bensalah, M., Dogui, A., Frouin, F., Mousseaux, É., & Cesare, A. D. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22124 · Cited by 118 · cited 1×
“25 A deep learning–based approach was used by Bratt et al for fully automated aortic 2D segmentation and flow quantification, achieving an average DS of 0.94 and high flow correlations to manual and alternative automated segmentation methods ( N = 270).”
InfluentialBratt, A. K., Kim, J. J., Pollie, M., Beecy, A., Tehrani, N. H., Codella, N., Pérez-Johnston, R., Palumbo, M. C., Alakbarli, J., Colizza, W. A., et al. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0509-0 · Cited by 92 · cited 1×
“26 We achieved a similar level of performance as 2D phase-contrast MRI segmentations for the 3D segmentation of 4D flow.”
4D Flow MRI Applications for Aortic Disease
Burris, N. S., & Hope, M. D. (2014) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2014.08.006 · Cited by 88 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialAutomated multi-atlas segmentation of cardiac 4D flow MRI
Bustamante, M., Gupta, V., Forsberg, D., Carlhäll, C., Engvall, J. E., & Ebbers, T. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.08.003 · Cited by 69 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
InfluentialSchnell, S., Entezari, P., Mahadevia, R. J., Malaisrie, S. C., McCarthy, P. M., Collins, J. D., Carr, J., & Markl, M. (2015) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000312 · Cited by 37 · cited 4×
“Age (years) 44 (2-91) 42 (2-80) 45 (2-91) 48 (19-81)”
Self-citation
Cited by
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
Self-citation
Metadata
- Authors
- Berhane, H., Scott, M., Elbaz, M., Jarvis, K., McCarthy, P., Carr, J., Malaisrie, C., Avery, R., Barker, A. J., Robinson, J. D., Rigsby, C. K., & Markl, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2020-03-13
- Volume
- 84
- Issue
- 4
- Pages
- 2204-2218
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W3010725820
- Cited by
- 160
- References
- 20
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.