The DOI matches its Crossref record.
Concomitant gradient terms in phase contrast MR: Analysis and correction
Abstract
Whenever a linear gradient is activated, concomitant magnetic fields with non‐linear spatial dependence result. This is a consequence of Maxwell's equations, i.e., within the imaging volume the magnetic field must have zero divergence, and has negligible curl. The concomitant, or Maxwell field has been described in the MRI literature for over 10 years. In this paper, we theoretically and experimentally show the existence of two additional lowest‐order terms in the concomitant field, which we call cross‐terms. The concomitant gradient cross‐terms only arise when the longitudinal gradient G z is simultaneously active with a transverse gradient (G x or G y). The effect of all of the concomitant gradient terms on phase contrast imaging is examined in detail. Several methods for reducing or eliminating phase errors arising from the concomitant magnetic field are described. The feasibility of a joint pulse sequence‐reconstruction method, which requires no increase in minimum TE, is demonstrated. Since the lowest‐order terms of the concomitant field are proportional to G2/B0, the importance of concomitant gradient terms is expected to increase given the current interest in systems with stronger gradients and/or weaker main magnetic fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design and validation of Segment - freely available software for cardiovascular image analysis
Heiberg, E., Sjögren, J., Ugander, M., Carlsson, M., Engblom, H., & Arheden, H. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-1 · Cited by 929
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
DENSE: Displacement Encoding with Stimulated Echoes in Cardiac Functional MRI
Aletras, A. H., Ding, S., Balaban, R. S., & Wen, H. (1999) · Journal of Magnetic Resonance · doi:10.1006/jmre.1998.1676 · Cited by 526
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Bicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns
Hope, M. D., Hope, T. A., Meadows, A. K., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2010) · Radiology · doi:10.1148/radiol.09091437 · Cited by 417
Metadata
- Authors
- Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-02
- Volume
- 39
- Issue
- 2
- Pages
- 300-308
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1965852118
- Cited by
- 547
- References
- 0
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concomitant gradient terms in phase contrast MR: Analysis and correction. https://app.cochat.ai/papers/10.1002/mrm.1910390218
- The paper
- Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998). Concomitant gradient terms in phase contrast MR: Analysis and correction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910390218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.