The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High‐frequency electrical conduction block of mammalian peripheral motor nerve
Abstract
A quick‐acting, quick‐reversing method for blocking action potentials in peripheral nerves could be used in the treatment of muscle spasticity and pain. A high‐frequency alternating‐current (HFAC) sinusoidal waveform is one possible means for providing this type of block. HFAC was used to block peripheral motor nerve activity in an in vivo mammalian model. Frequencies from 10 to 30 kH Z at amplitudes of between 2 and 10 V were investigated. A complete and reversible motor block was obtained at all frequencies. The block threshold amplitudes showed a linear relationship with frequency, the lowest threshold being at 10 kH Z. HFAC block has three phases: an onset response; a period of asynchronous firing; and a steady state of complete or partial block. The onset response and the asynchronous firing can be minimized by using an optimal frequency–amplitude combination. In general, the onset response was lowest for the combination of 30 kH Z and 10 V. Muscle Nerve, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318
Cited by
Deer, T. R., Mekhail, N., Provenzano, D., Pope, J., Krames, E., Leong, M., Levy, R. M., Abejon, D., Buchser, E., Burton, A., et al. (2014) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12208 · Cited by 596
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
Role of the vagus nerve in the development and treatment of diet‐induced obesity
de Lartigue, G. (2016) · The Journal of Physiology · doi:10.1113/jp271538 · Cited by 238
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123
Metadata
- Authors
- Bhadra, N., & Kilgore, K. L.
- Venue
- Muscle & Nerve
- Publisher
- Wiley
- Published
- 2005-08-25
- Volume
- 32
- Issue
- 6
- Pages
- 782-790
- ISSN
- 0148-639X (ISSN-L)
- 1097-4598
- OpenAlex
- W1979047378
- Cited by
- 239
- References
- 1
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High‐frequency electrical conduction block of mammalian peripheral motor nerve. https://app.cochat.ai/papers/10.1002/mus.20428
- The paper
- Bhadra, N., & Kilgore, K. L. (2005). High‐frequency electrical conduction block of mammalian peripheral motor nerve. Muscle & Nerve. https://doi.org/10.1002/mus.20428
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.