Retest reliability of surface electromyography on the pelvic floor muscles
The DOI matches its Crossref record.
Abstract
Aims: The aim of the current study was to evaluate the retest reliability of repeated intravaginal surface electromyography (surface EMG) of the pelvic floor muscles in healthy women, who were able to perform correct pelvic floor muscle contractions. Methods: Seventeen nullipara women in the age of 20–35 years completed the measurements. The surface EMG was performed with the subjects in supine position with knees bent. The surface and ground electrodes were attached to a vaginal probe. A total of three test sessions were conducted, two on the same day with 30 minutes apart and a third 26–30 days later. Each test session consisted of three maximum contractions, 10 seconds hold and 10 seconds rest. Results: Average activity, peak, work and baseline showed good to high reliability (ICC = 0.83–0.96). The reliability was somewhat higher in‐between test session one and two compared with test session number three. Generally choosing the highest contraction in one test session resulted in a slightly higher ICC than taking an average result of all three contractions. Conclusions: The current study shows that surface EMG is a reliable method of assessing pelvic floor muscle activity in healthy women. Neurourol. Urodynam. 28:395–399, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface EMG in Clinical Assessment and Neurorehabilitation: Barriers Limiting Its Use
Campanini, I., Disselhorst-Klug, C., Rymer, W. Z., & Merletti, R. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00934 · Cited by 270
Triboelectric Nanogenerators for Therapeutic Electrical Stimulation
Conta, G., Libanori, A., Tat, T., Chen, G., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202007502 · Cited by 205
Gentilcore-Saulnier, E., McLean, L., Goldfinger, C., Pukall, C. F., & Chamberlain, S. (2010) · The Journal of Sexual Medicine · doi:10.1111/j.1743-6109.2009.01642.x · Cited by 195
Stüpp, L., Resende, A. P. M., Oliveira, E., Castro, R. A., Girão, M. J. B. C., & Sartori, M. G. F. (2011) · International Urogynecology Journal · doi:10.1007/s00192-011-1428-x · Cited by 85
Resende, A. P. M., Stüpp, L., Bernardes, B. T., Oliveira, E., Castro, R. A., Girão, M. J. B. C., & Sartori, M. G. F. (2012) · Neurourology and Urodynamics · doi:10.1002/nau.21149 · Cited by 63
“The evaluation parameter was the root mean square and was considered as the best of the three contractions.(9,10) Each evaluation was carried out over a 2-min interval.”
MethodFerla, L., Darski, C., Paiva, L. L., Sbruzzi, G., & Vieira, A. (2016) · Fisioterapia em Movimento · doi:10.1590/0103-5150.029.002.ao19 · Cited by 30
Romero-Otero, J., Lauterbach, R., Aversa, A., Serefoglu, E. C., García-Gómez, B., Parnham, A., Skrodzka, M., Krychman, M., Reisman, Y., Corona, G., et al. (2020) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2020.02.013 · Cited by 16
Metadata
- Authors
- Grape, H. H., Dedering, Å., & Jonasson, A. F.
- Venue
- Neurourology and Urodynamics
- Publisher
- Wiley
- Published
- 2009-02-12
- Volume
- 28
- Issue
- 5
- Pages
- 395-399
- ISSN
- 0733-2467 (ISSN-L)
- 1520-6777
- OpenAlex
- W2085726913
- Cited by
- 127
- References
- 0
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.