Parallel RF transmission in MRI
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Following the development of parallel imaging, parallel transmission describes the use of multiple RF transmit coils. Parallel transmission can be applied to improve RF excitation, in particular, multidimensional, spatially selective RF excitation. For instance, parallel transmission is able to shorten spatially selective RF pulses in two or three dimensions, or to minimize the occurring SAR. One potential major application might be the compensation of patient‐induced B1 inhomogeneities, particularly at high main fields. This paper provides an overview of selected aspects of this new transmission approach. The basic principles of parallel transmission are discussed, initial experimental proofs are described, and the impact of error propagation on coil design for parallel transmission is outlined. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 18×
“The underlying hardware could thus be considered as a multielement transmit coil array, which allows independent adjustment to: U. Katscher, Philips Research Laboratories, 24–26, D-22335 Hamburg, Germany. tscher@philips.com sed: FOX, field of excitation; MR, magnetic resonetic resonance imaging; RF, radio frequency; S…”
BackgroundInfluentialRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322 · cited 15×
“Formally, the Fi can be interpreted via eqn (2) as the asymptotic limit of spatially selective RF pulses with a pulse length reduced to only one data point, i.”
BackgroundMethodInfluentialSimultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142 · cited 6×
“It is important to note that the system noise does not interact with the central matrix inversion [eqn (5)].”
BackgroundInfluentialKatscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Self-citationTransmit and receive transmission line arrays for 7 Tesla parallel imaging
Adriany, G., Van de Moortele, P., Wiesinger, F., Moeller, S., Strupp, J. P., Andersen, P., Snyder, C., Zhang, X., Chen, W., Pruessmann, K. P., et al. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20321 · Cited by 421 · cited 1×
“pfull 1⁄4 s full sfull s full þ l 1 pdes (10)”
BackgroundVariable-rate selective excitation
Conolly, S., Nishimura, D., Macovski, A., & Glover, G. (1988) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(88)90131-x · Cited by 321 · cited 1×
“, the impact of the k-space trajectory on the occurring SAR (43) or designing three-dimensional trajectories exciting slices with a sharp profile and a low resolution in-plane homogeneity correction (44).”
BackgroundComparison of linear and circular polarization for magnetic resonance imaging
Glover, G. H., Hayes, C. E., Pelc, N. J., Edelstein, W. A., Mueller, O. M., Hart, H. R., Hardy, C. J., O'Donnell, M., & Barber, W. D. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90349-x · Cited by 265
Fast MRI data acquisition using multiple detectors
Hutchinson, M., & Raff, U. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060110 · Cited by 195 · cited 3×
“The reduction of the RF power can be demonstrated by solving eqn (4) using a modified least square error function d:”
BackgroundMethodCoupling and decoupling theory and its application to the MRI phased array
Lee, R. F., Giaquinto, R. O., & Hardy, C. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10186 · Cited by 184
A strategy for sampling on a sphere applied to 3D selective RF pulse design
Wong, S. T. S., & Roos, M. S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320614 · Cited by 159
Cited by
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
7‐T MR—from research to clinical applications?
Moser, E., Stahlberg, F., Ladd, M. E., & Trattnig, S. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1794 · Cited by 187
Segmentation and quantification of adipose tissue by magnetic resonance imaging
Hu, H. H., Chen, J., & Shen, W. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0498-z · Cited by 90
“Multi-channel radiofrequency transmit technology has been introduced in recent years to mitigate the effects of B1+ inhomogeneities [73].”
Background
Metadata
- Authors
- Katscher, U., & Börnert, P.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2006-05
- Volume
- 19
- Issue
- 3
- Pages
- 393-400
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2044032240
- Cited by
- 214
- References
- 16
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parallel RF transmission in MRI. https://app.cochat.ai/papers/10.1002/nbm.1049
- The paper
- Katscher, U., & Börnert, P. (2006). Parallel RF transmission in MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.1049
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.