Muscle blood flow and oxygenation measured by NMR imaging and spectroscopy
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Tissue perfusion and oxygenation in many organs can be evaluated by various NMR techniques. This review focuses on the specificities, limitations and adaptations of the NMR tools available to investigate perfusion and oxygenation in the skeletal muscle of humans and animal models. A description of how they may be used simultaneously is provided as well. 1 H NMR spectroscopy of myoglobin (Mb) monitors intramyocytic oxygenation. It measures the level of deoxy‐Mb, from which Mb concentration, Mb desaturation/resaturation rates, muscle oxygenation changes and intracellular partial oxygen pressure (pO 2) can be calculated. Positive and negative blood oxygen level‐dependent (BOLD) contrasts exist in skeletal muscle. BOLD contrasts primarily reflect changes in capillary–venous oxygenation, but are also directly or indirectly dependent on muscle blood volume, perfusion, vascular network architecture and angulation, relative to the main magnetic field. Arterial spin labelling (ASL) techniques, having high spatial and temporal resolution, are the methods of choice to quantify and map skeletal muscle perfusion non‐invasively. Limitations of ASL are poor contrast‐to‐noise ratio and sensitivity to movement; however, with the introduction of specific adaptations, it has been proven possible to measure skeletal muscle perfusion at both rest and during exercise. The possibility of combining these NMR measurements with others into a single dynamic protocol is most interesting. The ‘multiparametric functional (mpf) NMR’ concept can be extended to include the evaluation of muscle energy metabolism simultaneously with 31 P NMR or with lactate double quantum filtered 1 H NMR spectroscopy, an approach which would make NMR an exceptional tool for non‐invasive investigations of integrative physiology and biochemistry in skeletal muscle in vivo. Copyright © 2006 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Logothetis, N. K., & Wandell, B. A. (2004) · Annual Review of Physiology · doi:10.1146/annurev.physiol.66.082602.092845 · Cited by 1,568
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134 · cited 1×
“A non-exhaustive list includes: blood vessel distribution and architecture (3) blood flow velocity (4) regional perfusion and blood volume (5, 6), blood (7) and tissue (8) oxygenation, distribution of high-energy phosphates (9), lactate production (10) and intracellular pH (11), Krebs cycle activity and mitochondrial…”
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647 · cited 2×
“a maximum at approximately 50% of maximal voluntary contraction (MVC) (30, 31) a discrepancy which may be partly attributable to anatomical or regulatory differences between muscle groups.”
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Cited by
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
Self-citationEvaluation of cuff-induced ischemia in the lower extremity by magnetic resonance oximetry
Langham, M. C., Floyd, T. F., Mohler, E. R., Magland, J. F., & Wehrli, F. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.068 · Cited by 46
Metadata
- Authors
- Carlier, P. G., Bertoldi, D., Baligand, C., Wary, C., & Fromes, Y.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2006-10-31
- Volume
- 19
- Issue
- 7
- Pages
- 954-967
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2015168951
- Cited by
- 75
- References
- 4
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.