CoChat

Evaluation of two‐dimensional L‐COSY and JPRESS using a 3 T MRI scanner: from phantoms to human brain in vivo

Thomas, M. Albert, Hattori, Noriaki, Umeda, Masahiro, Sawada, Tohru, Naruse, Shoji · 2003 · NMR in Biomedicine
Cited by 87

The DOI matches its Crossref record.

Abstract

Localized versions of two‐dimensional (2D) magnetic resonance spectroscopic (MRS) sequences, namely JPRESS and L‐COSY, have been implemented on a whole‐body 3T MRI/MRS scanner. Volume selection was achieved using three slice‐selective radio‐frequency (RF) pulses: 90°–180°–180° in JPRESS and 90°–180°–90° in L‐COSY with a CHESS sequence prior to voxel localization for global water suppression. The last 180° RF pulse was used for resolving the J‐coupled cross peaks in JPRESS, whereas the last 90° RF pulse was used for coherence transfer between J‐coupled metabolites in L‐COSY. A head MRI coil for ‘transmission’ and a 4 inch receive surface coil for ‘reception’ or a head coil transmit/receive were used. A total of 16 healthy volunteers were investigated using these 2D MRS sequences. Voxel sizes of 18 and 27 ml were localized in the occipito‐parietal gray and white matter regions and the total duration for each 2D signal acquisition was typically 35 min. Compared with 2D L‐COSY, reduced spectral width along the second spectral dimension and shorter 2D spectral acquisition were the major advantages of 2D JPRESS. In contrast, increased spectral width along the new spectral dimension in L‐COSY resulted in an improved spectral dispersion enabling the detection of several brain metabolites at low concentrations that have not been resolved using the conventional one‐dimensional (1D) MRS techniques. Due to increased sampling rate, severe loss of metabolite signals due to T2 during t1 was a major drawback of 2D JPRESS in vivo. Copyright © 2003 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/nbm.825

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 87

Metadata

Authors
Thomas, M. A., Hattori, N., Umeda, M., Sawada, T., & Naruse, S.
Venue
NMR in Biomedicine
Publisher
Wiley
Published
2003-08
Volume
16
Issue
5
Pages
245-251
ISSN
  • 0952-3480 (ISSN-L)
  • 1099-1492
OpenAlex
W1999853533
Cited by
87
References
0
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of two‐dimensional L‐COSY and JPRESS using a 3 T MRI scanner: from phantoms to human brain in vivo. https://app.cochat.ai/papers/10.1002/nbm.825
The paper
Thomas, M. A., Hattori, N., Umeda, M., Sawada, T., & Naruse, S. (2003). Evaluation of two‐dimensional L‐COSY and JPRESS using a 3 T MRI scanner: from phantoms to human brain in vivo. NMR in Biomedicine. https://doi.org/10.1002/nbm.825

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.