The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Manganese‐enhanced magnetic resonance imaging (MEMRI): methodological and practical considerations
Abstract
Manganese‐enhanced MRI (MEMRI) is being increasingly used for MRI in animals due to the unique T1 contrast that is sensitive to a number of biological processes. Three specific uses of MEMRI have been demonstrated: to visualize activity in the brain and the heart; to trace neuronal specific connections in the brain; and to enhance the brain cytoarchitecture after a systemic dose. Based on an ever‐growing number of applications, MEMRI is proving useful as a new molecular imaging method to visualize functional neural circuits and anatomy as well as function in the brain in vivo. Paramount to the successful application of MEMRI is the ability to deliver Mn 2+ to the site of interest at an appropriate dose and in a time‐efficient manner. A major drawback to the use of Mn 2+ as a contrast agent is its cellular toxicity. Therefore, it is critical to use as low a dose as possible. In the present work the different approaches to MEMRI are reviewed from a practical standpoint. Emphasis is given to the experimental methodology of how to achieve significant, yet safe, amounts of Mn 2+ to the target areas of interest. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Lin, Y., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380305 · Cited by 485
Self-citationManganese‐Induced Parkinsonism and Parkinson's Disease
Olanow, C. W. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1306.018 · Cited by 468
In vivo neuronal tract tracing using manganese‐enhanced magnetic resonance imaging
Pautler, R. G., Silva, A. C., & Koretsky, A. P. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400515 · Cited by 443
Self-citationManganese and extrapyramidal disorders (a critical review and tribute to Dr. George C. Cotzias).
Barbeau, A. (1984) · PubMed · Cited by 301
Agonists stimulate divalent cation channels in the plasma membrane of human platelets
Hallam, T. J., & Rink, T. J. (1985) · FEBS Letters · doi:10.1016/0014-5793(85)80703-1 · Cited by 299
Tjälve, H., Henriksson, J., Tallkvist, J., Larsson, B. S., & Lindquist, N. G. (1996) · Pharmacology & Toxicology · doi:10.1111/j.1600-0773.1996.tb00021.x · Cited by 273
In vivo detection of neuroarchitecture in the rodent brain using manganese-enhanced MRI
Aoki, I., Wu, Y.-J. L., Silva, A. C., Lynch, R. M., & Koretsky, A. P. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.031 · Cited by 269
Self-citationDuong, T. Q., Silva, A. C., Lee, S.-P., & Kim, S.-G. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200003)43:3<383::aid-mrm10>3.0.co;2-q · Cited by 254
Self-citationPautler, R. G., & Koretsky, A. P. (2002) · NeuroImage · doi:10.1006/nimg.2002.1075 · Cited by 233
Self-citationMagnetic Resonance Imaging of Neuronal Connections in the Macaque Monkey
Saleem, K. S., Pauls, J. M., Augath, M., Trinath, T., Prause, B. A., Hashikawa, T., & Logothetis, N. K. (2002) · Neuron · doi:10.1016/s0896-6273(02)00718-3 · Cited by 217
Axonal transport of manganese and its relevance to selective neurotoxicity in the rat basal ganglia
Sloot, W. N., & Gramsbergen, J.-B. P. (1994) · Brain Research · doi:10.1016/0006-8993(94)90959-8 · Cited by 205
Paramagnetic contrast agents in nuclear magnetic resonance medical imaging
Mendonça-Dias, M. H., Gaggelli, E., & Lauterbur, P. C. (1983) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(83)80048-8 · Cited by 202
Drapeau, P., & Nachshen, D. A. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015121 · Cited by 190
Rapid Brain Uptake of Manganese(II) Across the Blood‐Brain Barrier
Rabin, O., Hegedus, L., Bourre, J., & Smith, Q. R. (1993) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1993.tb02153.x · Cited by 184
Lin, C.-P., Tseng, W.-Y. I., Cheng, H.-C., & Chen, J.-H. (2001) · NeuroImage · doi:10.1006/nimg.2001.0882 · Cited by 184
Lee, J. H., Silva, A. C., Merkle, H., & Koretsky, A. P. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20368 · Cited by 170
Self-citationder Linden, A. V., Verhoye, M., Meir, V. V., Tindemans, I., Eens, M., Absil, P., & Balthazart, J. (2002) · Neuroscience · doi:10.1016/s0306-4522(02)00070-2 · Cited by 143
Pautler, R. G., Mongeau, R., & Jacobs, R. E. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10498 · Cited by 143
High-resolution 3D MRI of mouse brain reveals small cerebral structures in vivo
Natt, O., Watanabe, T., Boretius, S., Radulović, J., Frahm, J., & Michaelis, T. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00211-x · Cited by 133
Dynamic activity‐induced manganese‐dependent contrast magnetic resonance imaging (DAIM MRI)
Aoki, I., Tanaka, C., Takegami, T., Ebisu, T., Umeda, M., Fukunaga, M., Fukuda, K., Silva, A. C., Koretsky, A. P., & Naruse, S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10320 · Cited by 127
Self-citationManganese‐enhanced MRI of mouse heart during changes in inotropy
Hu, T. C., Pautler, R. G., MacGowan, G. A., & Koretsky, A. P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1273 · Cited by 126
Self-citationIn vivo 3D MRI staining of mouse brain after subcutaneous application of MnCl2
Watanabe, T., Natt, O., Boretius, S., Frahm, J., & Michaelis, T. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10276 · Cited by 119
Silva, A. C., Zhang, W., Williams, D. S., Koretsky, A. P., & Koretsky, A. P. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370110 · Cited by 114
Self-citationHunter, D. R., Haworth, R. A., & Berkoff, H. A. (1981) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(81)90239-x · Cited by 78
Saeed, M., Higgins, C. B., Geschwind, J. F., & Wendland, M. F. (2000) · European Radiology · doi:10.1007/s003300050050 · Cited by 72
Bremerich, J., Saeed, M. A., Arheden, H., et al. (2000) · Radiology · doi:10.1148/radiology.216.2.r00jl14524 · Cited by 64
ALLEGRINI, P. R., & Wießner, C. (2003) · NMR in Biomedicine · doi:10.1002/nbm.834 · Cited by 61
Direct CSF injection of MnCl2 for dynamic manganese‐enhanced MRI
Liu, C. H., D'Arceuil, H. E., & de Crespigny, A. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20047 · Cited by 59
Meir, V. V., Verhoye, M., Absil, P., Eens, M., Balthazart, J., & der Linden, A. V. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.10.007 · Cited by 55
Nordhøy, W., Anthonsen, H. W., Bruvold, M., Jynge, P., Krane, J., & Brurok, H. (2003) · NMR in Biomedicine · doi:10.1002/nbm.817 · Cited by 54
Metals and metal compounds in carcinogenesis.
Desoize, B. (2003) · PubMed · Cited by 54
Osmotic blood-brain barrier disruption: a new means of increasing chemotherapeutic agent delivery.
Neuwelt, E. A., Frenkel, E. P., Diehl, J. T., Maravilla, K. R., Vu, L. H., Clark, W. K., Рапопорт, С. И., Barnett, P. A., Hill, S. A., Lewis, S. E., et al. (1979) · PubMed · Cited by 52
Detection of the anoxic depolarization of focal ischemia using manganese‐enhanced MRI
Aoki, I., Ebisu, T., Tanaka, C., Katsuta, K., Fujikawa, A., Umeda, M., Fukunaga, M., Takegami, T., Shapiro, E. M., & Naruse, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10528 · Cited by 49
Self-citationContrast-enhanced MR Delineation of Stunned Myocardium with Administration of MnCl2in Rats
Krombach, G. A., Saeed, M., Higgins, C. B., Novikov, V. I., & Wendland, M. F. (2004) · Radiology · doi:10.1148/radiol.2301020228 · Cited by 46
Brurok, H., Skoglund, T., Berg, K., Skarra, S., Karlsson, J., & Jynge, P. (1999) · NMR in Biomedicine · Cited by 40
Shibuya, I., & Douglas, W. W. (1993) · Cell Calcium · doi:10.1016/0143-4160(93)90016-y · Cited by 38
Hand, J. W., Lagendijk, J. J. W., Hajnal, J. V., Lau, R. W. M., & YOUNG, I. R. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<186::aid-jmri21>3.0.co;2-2 · Cited by 23
Cited by
Inorganic Nanoparticles for MRI Contrast Agents
Na, H. B., Song, I. C., & Hyeon, T. (2009) · Advanced Materials · doi:10.1002/adma.200802366 · Cited by 1,781
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Maruyama, M., Shimada, H., Suhara, T., Shinotoh, H., Ji, B., Maeda, J., Zhang, M.-R., Trojanowski, J. Q., Lee, V. M.-Y., Ono, M., et al. (2013) · Neuron · doi:10.1016/j.neuron.2013.07.037 · Cited by 760
Self-citationDevelopment of a T1 Contrast Agent for Magnetic Resonance Imaging Using MnO Nanoparticles
Na, H. B., Lee, J. H., An, K., Park, Y. I., Park, M., Lee, I. S., Nam, D., Kim, S. T., Kim, S., Kim, S., et al. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604775 · Cited by 614
Self-citationClassification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Metadata
- Authors
- Silva, A. C., Lee, J. H., Aoki, I., & Koretsky, A. P.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2004-11
- Volume
- 17
- Issue
- 8
- Pages
- 532-543
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2093360003
- Cited by
- 486
- References
- 39
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.