Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Manganese‐enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: Dose‐dependent and temporal evolution of T1 contrast

Lee, Jung Hee, Silva, Afonso C., Merkle, Hellmut, Koretsky, Alan P. · 2005 · Magnetic Resonance in Medicine

Abstract

Manganese is a useful contrast agent for MRI of animals. Previously, it has been shown that systemic doses of MnCl 2 provide unique contrast in the rodent brain, enabling visualization of neuroarchitecture. The present work investigates the dose and temporal dependence of brain enhancement after i.v. administration of MnCl 2. Varying doses of MnCl 2 (9–175 mg/kg) were administered to mice from 0 to 24 h prior to T1‐weighted manganese‐enhanced MRI (MEMRI) at 11.7 T. Pre‐MnCl 2 T1 values measured in different brain regions ranged from 1.17 ± 0.03 to 1.76 ± 0.01 s. Post‐MnCl 2 T 1 measured 24 hr after administration of MnCl 2 were significantly decreased, even after the lowest dose of MnCl 2. The largest decreases occurred in the pituitary gland, where post‐MnCl 2 T1 ranged from 231 ± 23 ms following the lowest dose to 143 ± 43 ms after the highest dose, while the smallest decreases were observed in cortex (post‐MnCl 2 T1 = 1060 ± 5 ms for low dose and 637 ± 5 ms for high dose). The contrast resulting after 14 hr did not change up to 24 hr. Enhancement first occurred in subarachnoid spaces, followed by ventricles and periventricular tissues, and finally reached the remainder of the brain. Cortical layers were detected at higher doses (>88 mg/kg) and olfactory bulb layers were detected with the lowest dose (9 mg/kg). Temporal evolution of the enhancement of the olfactory bulb layers was observed. In some regions of the brain, such as hippocampus and thalamus, the changes in contrast detected between 2 and 14 hr used very specific pathways. These results demonstrate that both the dose and the time after MnCl 2 can be manipulated to optimize brain contrast in a region‐specific manner. Published 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20368

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 170

Metadata

Authors
Lee, J. H., Silva, A. C., Merkle, H., & Koretsky, A. P.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-02-18
Volume
53
Issue
3
Pages
640-648
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2165298588
Cited by
170
References
3
FWCI
10.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Manganese‐enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: Dose‐dependent and temporal evolution of T1 contrast. https://app.cochat.ai/papers/10.1002/mrm.20368
The paper
Lee, J. H., Silva, A. C., Merkle, H., & Koretsky, A. P. (2005). Manganese‐enhanced magnetic resonance imaging of mouse brain after systemic administration of MnCl2: Dose‐dependent and temporal evolution of T1 contrast. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.