Looking for biogenic magnetite in brain ferritin using NMR relaxometry
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Mammalian cellular iron is stored inside the multisubunit protein ferritin, normally taking the structure of a ferrihydrite‐like mineral core. It has been suggested that biogenic magnetite, which has been detected in the brain and may be related to neurodegenerative diseases such as Alzheimer's and Parkinson's diseases, could initially form in ferritin. Indeed, as ferritin is present in the brain, the ferrihydrite core could be a precursor for biogenic magnetite formation – particularly in cases where the normal functioning of the ferritin protein is disrupted. In this work, NMR relaxometry was used to detect magnetite inside samples of ferritin extracted from normal and Alzheimer‐diseased brains. The method was first calibrated with different fractions of horse spleen ferritin and synthetic magnetite particles. The relaxometry results suggest that the proportion of iron contained in brain ferritin in the form of well‐crystallized magnetite instead of ferrihydrite must be <1%, which is much less than that reported for ‘magnetite‐like’ phase in recent transmission electron microscopy studies of similar samples. Consequently, the magnetization of this ‘magnetite‐like’ phase must be very low compared with that of magnetite. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zecca, L., Gallorini, M., Schünemann, V., Trautwein, A. X., Gerlach, M., Riederer, P., Vezzoni, P., & Tampellini, D. (2001) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2001.00186.x · Cited by 401 · cited 1×
“For example, our experimental procedure does not select iron compounds related to other proteins present in the brain, such as neuromelanin, lipofuscin and hemosiderin.(20) The last compound, which is a partially denatured form of ferritin, is not soluble and was probably eliminated during centrifugation.”
Method
Cited by
Ordered ferrimagnetic form of ferrihydrite reveals links among structure, composition, and magnetism
Michel, F. M., Barrón, V., Torrent, J., Morales, M. P., Serna, C. J., Boily, J.-F., Liu, Q., Ambrosini, A., Cismasu, A. C., & Brown, G. E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910170107 · Cited by 375
Iron, myelin, and the brain: neuroimaging meets neurobiology
Möller, H. E., Bossoni, L., Connor, J. R., Crichton, R. R., Does, M. D., Ward, R. J., Zecca, L., Zucca, F. A., & Ronen, I. (2019) · Trends in Neurosciences · doi:10.1016/j.tins.2019.03.009 · Cited by 207
Meadowcroft, M. D., Connor, J. R., Smith, M. B., & Yang, Q. X. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21731 · Cited by 176
Antharam, V., Collingwood, J. F., Bullivant, J.-P., Davidson, M. R., Chandra, S., Mikhaylova, A., Finnegan, M. E., Batich, C., Forder, J. R., & Dobson, J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.019 · Cited by 82
“Magnetite, an iron oxide with a magnetic moment more than 100 times higher than the normal iron storage protein ferritin, could also have an effect on MRI measurement (Gossuin et al., 2005) if present in higher concentrations in AD (Hautot et al., 2003; Quintana et al., 2004).”
BackgroundSelf-citation
Metadata
- Authors
- Gossuin, Y., Hautot, D., Muller, R. N., Pankhurst, Q., Dobson, J., Morris, C., Gillis, P., & Collingwood, J.
- Venue
- NMR in Biomedicine
- Publisher
- Wiley
- Published
- 2005-09-21
- Volume
- 18
- Issue
- 7
- Pages
- 469-472
- ISSN
- 0952-3480 (ISSN-L)
- 1099-1492
- OpenAlex
- W2125569650
- Cited by
- 32
- References
- 1
- FWCI
- 0.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.