The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Measuring breath acetone for monitoring fat loss: Review
Open accessAbstract
Objective: Endogenous acetone production is a by‐product of the fat metabolism process. Because of its small size, acetone appears in exhaled breath. Historically, endogenous acetone has been measured in exhaled breath to monitor ketosis in healthy and diabetic subjects. Recently, breath acetone concentration (BrAce) has been shown to correlate with the rate of fat loss in healthy individuals. In this review, the measurement of breath acetone in healthy subjects is evaluated for its utility in predicting fat loss and its sensitivity to changes in physiologic parameters. Results: BrAce can range from 1 ppm in healthy non‐dieting subjects to 1,250 ppm in diabetic ketoacidosis. A strong correlation exists between increased BrAce and the rate of fat loss. Multiple metabolic and respiratory factors affect the measurement of BrAce. BrAce is most affected by changes in the following factors (in descending order): dietary macronutrient composition, caloric restriction, exercise, pulmonary factors, and other assorted factors that increase fat metabolism or inhibit acetone metabolism. Pulmonary factors affecting acetone exchange in the lung should be controlled to optimize the breath sample for measurement. Conclusions: When biologic factors are controlled, BrAce measurement provides a non‐invasive tool for monitoring the rate of fat loss in healthy subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Determinants of fat oxidation during exercise in healthy men and women: a cross-sectional study
Venables, M. C., Achten, J., & Jeukendrup, A. E. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00662.2003 · Cited by 503 · cited 3×
“Increasing exercise intensity beyond 65% VO2-max caused fat oxidation to decrease (50).”
BackgroundOptimizing fat oxidation through exercise and diet
Achten, J., & Jeukendrup, A. E. (2004) · Nutrition · doi:10.1016/j.nut.2004.04.005 · Cited by 361
Saslow, L. R., Kim, S., Daubenmier, J. J., Moskowitz, J. T., Phinney, S. D., Goldman, V., Murphy, E. J., Cox, R. M., Moran, P., & Hecht, F. M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091027 · Cited by 221
St-Onge, M.-P. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2348 · Cited by 220
Fat Metabolism During Exercise: A Review. Part III: Effects of Nutritional Interventions
Jeukendrup, A., Saris, W., & Wagenmakers, A. (1998) · International Journal of Sports Medicine · doi:10.1055/s-2007-971932 · Cited by 85
Effects of diet composition on postprandial energy availability during weight loss maintenance
Walsh, C. O., Ebbeling, C. B., Swain, J. F., Markowitz, R. L., Feldman, H. A., & Ludwig, D. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058172 · Cited by 40
Cited by
Breath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202200830 · Cited by 183
Metadata
- Authors
- Anderson, J. C.
- Venue
- Obesity
- Publisher
- Wiley
- Published
- 2015-11-02
- Volume
- 23
- Issue
- 12
- Pages
- 2327-2334
- ISSN
- 1930-7381 (ISSN-L)
- 1930-739X
- OpenAlex
- W1907388023
- Cited by
- 211
- References
- 7
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.