The DOI matches its Crossref record.
Energy payback and life‐cycle CO2 emissions of the BOS in an optimized 3·5 MW PV installation
Open accessAbstract
This study is a life‐cycle analysis of the balance of system (BOS) components of the 3·5 MW p multi‐crystalline PV installation at Tucson Electric Power's (TEP) Springerville, AZ field PV plant. TEP instituted an innovative PV installation program guided by design optimization and cost minimization. The advanced design of the PV structure incorporated the weight of the PV modules as an element of support design, thereby eliminating the need for concrete foundations. The estimate of the life‐cycle energy requirements embodied in the BOS is 542 MJ/m 2, a 71% reduction from those of an older central plant; the corresponding life‐cycle greenhouse gas emissions are 29 kg CO 2 eq./m 2. From field measurements, the energy payback time (EPT) of the BOS is 0·21 years for the actual location of this plant, and 0·37 years for average US insolation/temperature conditions. This is a great improvement from the EPT of about 1·3 years, estimated for an older central plant. The total cost of the balance of system components was $940 US per kW p of installed PV, another milestone in improvement. These results were verified with data from different databases and further tested with sensitivity‐ and data‐uncertainty analyses. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Emissions from Photovoltaic Life Cycles
Fthenakis, V. M., Kim, H. C., & Alsema, E. (2008) · Environmental Science & Technology · doi:10.1021/es071763q · Cited by 608
Self-citationPhotovoltaics: Life-cycle analyses
Fthenakis, V. M., & Kim, H. C. (2011) · Solar Energy · doi:10.1016/j.solener.2009.10.002 · Cited by 441
Self-citationPellow, M. A., Ambrose, H., Mulvaney, D., Betita, R., & Shaw, S. (2020) · Sustainable Materials and Technologies · doi:10.1016/j.susmat.2019.e00120 · Cited by 152
Dale, M., & Benson, S. M. (2013) · Environmental Science & Technology · doi:10.1021/es3038824 · Cited by 125
Bergesen, J. D., Heath, G. A., Gibon, T., & Suh, S. (2014) · Environmental Science & Technology · doi:10.1021/es405539z · Cited by 77
Metadata
- Authors
- Mason, J. E., Fthenakis, V. M., Hansen, T., & Kim, H. C.
- Venue
- Progress in Photovoltaics: Research and Applications
- Publisher
- Wiley
- Published
- 2005-09-28
- Volume
- 14
- Issue
- 2
- Pages
- 179-190
- ISSN
- 1062-7995 (ISSN-L)
- 1099-159X
- OpenAlex
- W2170207559
- Cited by
- 164
- References
- 0
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy payback and life‐cycle CO2 emissions of the BOS in an optimized 3·5 MW PV installation. https://app.cochat.ai/papers/10.1002/pip.652
- The paper
- Mason, J. E., Fthenakis, V. M., Hansen, T., & Kim, H. C. (2006). Energy payback and life‐cycle CO2 emissions of the BOS in an optimized 3·5 MW PV installation. Progress in Photovoltaics: Research and Applications. https://doi.org/10.1002/pip.652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.