Evaluation of absolute peptide quantitation strategies using selected reaction monitoring
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The use of internal peptide standards in selected reaction monitoring experiments enables absolute quantitation. Here, we describe three approaches addressing calibration of peptide concentrations in complex matrices and assess their performance in terms of trueness and precision. The simplest approach described is single reference point quantitation where a heavy peptide is spiked into test samples and the endogenous analyte quantified relative to the heavy peptide internal standard. We refer to the second approach as normal curve quantitation. Here, a constant amount of heavy peptide and a varying amount of light peptide are spiked into matrix to construct a calibration curve. This accounts for matrix effects but due to the presence of endogenous analyte, it is usually not possible to determine the lower LOQ. We refer to the third method as reverse curve quantitation. Here, a constant amount of light peptide and a varying amount of heavy peptide are spiked into matrix to construct a calibration curve. Because there is no contribution to the heavy peptide signal from endogenous analyte, it is possible to measure the equivalent of a blank sample and determine LOQ. These approaches are applied to human plasma samples and used to assay peptides of a set of apolipoproteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733 · cited 1×
“Heavy stable isotopes are commonly used to introduce a mass difference into the standards and are either directly incorporated into synthetic absolute quantitation (AQUA) peptides or added as part of a chemical derivatisation step such as tandem mass tag (TMT)-SRM [1, 2].”
Background
Cited by
Pannee, J., Portelius, E., Oppermann, M., Atkins, A., Hornshaw, M., Zegers, I., Höjrup, P., Minthon, L., Hansson, O., Zetterberg, H., et al. (2013) · Journal of Alzheimer’s Disease · doi:10.3233/jad-2012-121471 · Cited by 105
van den Broek, I., Smit, N. P. M., Romijn, F. P. H. T. M., van der Laarse, A., Deelder, A. M., van der Burgt, Y. E. M., & Cobbaert, C. M. (2013) · Journal of Proteome Research · doi:10.1021/pr400763d · Cited by 49
Smit, N. P. M., Romijn, F. P. H. T. M., van den Broek, I., Drijfhout, J. W., Haex, M., van der Laarse, A., van der Burgt, Y. E. M., & Cobbaert, C. M. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.06.015 · Cited by 32
“guanidine-HCl, trifluoroethanol (TFE), deoxycholate (DOC), sodium dodecyl sulfate (SDS) and the acid labile surfactant (ALS) Rapigest [18,19,24,25,41].”
BackgroundMethodInfluential
Metadata
- Authors
- Campbell, J., Rezai, T., Prakash, A., Krastins, B., Dayon, L., Ward, M., Robinson, S., & Lopez, M.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2011-02-16
- Volume
- 11
- Issue
- 6
- Pages
- 1148-1152
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2025114702
- Cited by
- 40
- References
- 2
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.