Parallel reaction monitoring using quadrupole‐Orbitrap mass spectrometer: Principle and applications
Abstract
Targeted mass spectrometry‐based approaches are nowadays widely used for quantitative proteomics studies and more recently have been implemented on high resolution/accurate mass (HRAM) instruments resulting in a considerable performance improvement. More specifically, the parallel reaction monitoring technique (PRM) performed on quadrupole‐Orbitrap mass spectrometers, leveraging the high resolution and trapping capabilities of the instrument, offers a clear advantage over the conventional selected reaction monitoring (SRM) measurements executed on triple quadrupole instruments. Analyses performed in HRAM mode allow for an improved discrimination between signals derived from analytes and those resulting from matrix interferences translating in the reliable quantification of low abundance components. The purpose of the study defines various implementation schemes of PRM, namely: (i) exploratory experiments assessing the detectability of very large sets of peptides (100–1000), (ii) wide‐screen analyses using (crude) internal standards to obtain statistically meaningful (relative) quantitative analyses, and (iii) precise/accurate quantification of a limited number of analytes using calibrated internal standards. Each of the three implementation schemes requires specific acquisition methods with defined parameters to appropriately control the acquisition during the actual peptide elution. This tutorial describes the different PRM approaches and discusses their benefits and limitations in terms of quantification performance and confidence in analyte identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Skyline: an open source document editor for creating and analyzing targeted proteomics experiments
MacLean, B., Tomazela, D. M., Shulman, N., Chambers, M., Finney, G. L., Frewen, B., Kern, R., Tabb, D. L., Liebler, D. C., & MacCoss, M. J. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq054 · Cited by 4,697
Gillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
ProteomeXchange provides globally coordinated proteomics data submission and dissemination
Vizcaíno, J. A., Deutsch, E. W., Wang, R., Csordas, A., Reisinger, F., Ríos, D., Dianes, J. A., Sun, Z., Farrah, T., Bandeira, N., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.2839 · Cited by 2,729
The Proteomics Identifications (PRIDE) database and associated tools: status in 2013
Vizcaíno, J. A., Côté, R. G., Csordas, A., Dianes, J. A., Fabregat, A., Foster, J. M., Griss, J., Alpi, E., Birim, M., Contell, J., et al. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks1262 · Cited by 1,918
Peng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
Optimization and testing of mass spectral library search algorithms for compound identification
Stein, S. E., & Scott, D. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)87009-8 · Cited by 882
Automated approach for quantitative analysis of complex peptide mixtures from tandem mass spectra
Venable, J. D., Dong, M.-Q., Wohlschlegel, J., Dillin, A., & Yates, J. R. (2004) · Nature Methods · doi:10.1038/nmeth705 · Cited by 794
Options and considerations when selecting a quantitative proteomics strategy
Domon, B., & Aebersold, R. (2010) · Nature Biotechnology · doi:10.1038/nbt.1661 · Cited by 605
Self-citationCarr, S. A., Abbatiello, S. E., Ackermann, B. L., Borchers, C., Domon, B., Deutsch, E. W., Grant, R. P., Hoofnagle, A. N., Hüttenhain, R., Koomen, J. M., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.036095 · Cited by 561
Self-citationmProphet: automated data processing and statistical validation for large-scale SRM experiments
Reiter, L., Rinner, O., Picotti, P., Hüttenhain, R., Beck, M., Brusniak, M.-Y., Hengartner, M. O., & Aebersold, R. (2011) · Nature Methods · doi:10.1038/nmeth.1584 · Cited by 532
Hebert, A. S., Richards, A. L., Bailey, D. J., Ulbrich, A., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034769 · Cited by 528
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Self-citationDynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Makarov, A., Denisov, E., Lange, O., & Horning, S. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.03.006 · Cited by 431
Nagaraj, N., Alexander Kulak, N., Cox, J., Neuhauser, N., Mayr, K., Hoerning, O., Vorm, O., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.013722 · Cited by 392
High Sensitivity Detection of Plasma Proteins by Multiple Reaction Monitoring of N-Glycosites
Stahl-Zeng, J., Lange, V., Ossola, R., Eckhardt, K., Krek, W., Aebersold, R., & Domon, B. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700132-mcp200 · Cited by 361
Self-citationTriple quadrupole mass spectrometry for direct mixture analysis and structure elucidation
Yost, R. A., & Enke, C. G. (1979) · Analytical Chemistry · doi:10.1021/ac50048a002 · Cited by 337
Deep and Highly Sensitive Proteome Coverage by LC-MS/MS Without Prefractionation
Thakur, S. S., Geiger, T., Chatterjee, B., Bandilla, P., Fröhlich, F., Cox, J., & Mann, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003699 · Cited by 337
Andrews, G. L., Simons, B. L., Young, J. B., Hawkridge, A. M., & Muddiman, D. C. (2011) · Analytical Chemistry · doi:10.1021/ac200812d · Cited by 285
Comparing similar spectra: From similarity index to spectral contrast angle
Wan, K. X., Vidavsky, I., & Gross, M. L. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(01)00327-0 · Cited by 243
Ronsein, G. E., Pamir, N., von Haller, P. D., Kim, D. S., Oda, M. N., Jarvik, G. P., Vaisar, T., & Heinecke, J. W. (2015) · Journal of Proteomics · doi:10.1016/j.jprot.2014.10.017 · Cited by 214
Gallien, S., Kim, S. Y., & Domon, B. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.043968 · Cited by 205
Self-citationQuantitative measurements of N‐linked glycoproteins in human plasma by SWATH‐MS
Liu, Y., Hüttenhain, R., Surinova, S., Gillet, L. C., Mouritsen, J., Brunner, R., Navarro, P., & Aebersold, R. (2013) · PROTEOMICS · doi:10.1002/pmic.201200417 · Cited by 204
Technical considerations for large-scale parallel reaction monitoring analysis
Gallien, S., Bourmaud, A., Kim, S. Y., & Domon, B. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2013.10.029 · Cited by 202
Self-citationAbbatiello, S. E., Mani, D. R., Keshishian, H., & Carr, S. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138420 · Cited by 198
Marx, V. (2013) · Nature Methods · doi:10.1038/nmeth.2285 · Cited by 183
Kelstrup, C. D., Jersie-Christensen, R. R., Batth, T. S., Arrey, T. N., Kuehn, A., Kellmann, M., & Olsen, J. V. (2014) · Journal of Proteome Research · doi:10.1021/pr500985w · Cited by 173
Selectivity of LC-MS/MS analysis: Implication for proteomics experiments
Gallien, S., Duriez, E., Demeure, K., & Domon, B. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.11.005 · Cited by 153
Self-citationAdvances in multiplexed MRM-based protein biomarker quantitation toward clinical utility
Percy, A. J., Chambers, A. G., Yang, J., Hardie, D. B., & Borchers, C. H. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.06.008 · Cited by 152
How specific is my SRM?: The issue of precursor and product ion redundancy
Sherman, J., McKay, M. J., Ashman, K., & Molloy, M. P. (2009) · PROTEOMICS · doi:10.1002/pmic.200800577 · Cited by 150
A Systematic Investigation into the Nature of Tryptic HCD Spectra
Michalski, A., Neuhauser, N., Cox, J., & Mann, M. (2012) · Journal of Proteome Research · doi:10.1021/pr3007045 · Cited by 143
Mani, D. R., Abbatiello, S. E., & Carr, S. A. (2012) · BMC Bioinformatics · doi:10.1186/1471-2105-13-s16-s9 · Cited by 136
Deconvolution of Mixture Spectra from Ion-Trap Data-Independent-Acquisition Tandem Mass Spectrometry
Bern, M. W., Finney, G. L., Hoopmann, M. R., Merrihew, G. E., Toth, M. J., & MacCoss, M. J. (2009) · Analytical Chemistry · doi:10.1021/ac901801b · Cited by 129
Schilling, B., MacLean, B., Held, J. M., Sahu, A. K., Rardin, M. J., Sorensen, D. J., Peters, T. W., Wolfe, A. J., Hunter, C. L., MacCoss, M. J., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02983 · Cited by 124
Mass spectrometry–based targeted proteomics
Doerr, A. J. (2012) · Nature Methods · doi:10.1038/nmeth.2286 · Cited by 98
Quantification of SAA1 and SAA2 in lung cancer plasma using the isotype‐specific PRM assays
Kim, Y. J., Gallien, S., El‐Khoury, V., Goswami, P., Sertamo, K., Schlesser, M., Berchem, G., & Domon, B. (2015) · PROTEOMICS · doi:10.1002/pmic.201400382 · Cited by 96
Self-citationThomas, S. N., Harlan, R., Chen, J., Aiyetan, P., Liu, Y., Sokoll, L. J., Aebersold, R. H., Chan, D. W., & Zhang, H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02063 · Cited by 81
Peptide Identification from Mixture Tandem Mass Spectra
Wang, J., Pérez‐Santiago, J., Katz, J. E., Mallick, P., & Bandeira, N. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m000136-mcp201 · Cited by 73
Tsuchiya, H., Tanaka, K., & Saeki, Y. (2013) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2013.05.080 · Cited by 73
Tang, H., Fang, H., Yin, E., Brasier, A. R., Sowers, L. C., & Zhang, K. (2014) · Analytical Chemistry · doi:10.1021/ac500972x · Cited by 67
Detection and quantification of proteins in clinical samples using high resolution mass spectrometry
Gallien, S., & Domon, B. (2015) · Methods · doi:10.1016/j.ymeth.2015.03.015 · Cited by 66
Self-citationTargeted proteomics strategy applied to biomarker evaluation
Kim, Y. J., Gallien, S., van Oostrum, J., & Domon, B. (2013) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201300070 · Cited by 42
Self-citationLesur, A., Ancheva, L., Kim, Y. J., Berchem, G., van Oostrum, J., & Domon, B. (2015) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201400158 · Cited by 33
Self-citationLongitudinal Urinary Protein Variability in Participants of the Space Flight Simulation Program
Khristenko, N. A., Larina, I. M., & Domon, B. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00594 · Cited by 31
Self-citationDetection and correction of interference in SRM analysis
Bao, Y., Waldemarson, S., Zhang, G., Wåhlander, Å., Ueberheide, B. M., Myung, S., Reed, B., Molloy, K. R., Padovan, J. C., Eriksson, J., et al. (2013) · Methods · doi:10.1016/j.ymeth.2013.05.008 · Cited by 24
Gallien, S., & Domon, B. (2014) · Bioanalysis · doi:10.4155/bio.14.115 · Cited by 17
Self-citation
Cited by
Phosphoproteins in extracellular vesicles as candidate markers for breast cancer
Chen, I.-H., Xue, L., Hsu, C.-C., Paez, J. S. P., Pan, L., Andaluz, H., Wendt, M. K., Iliuk, A. B., Zhu, J.-K., & Tao, W. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1618088114 · Cited by 472
Detection of selected tire wear compounds in urban receiving waters
Johannessen, C., Helm, P., & Metcalfe, C. D. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.117659 · Cited by 259
Clinical potential of mass spectrometry-based proteogenomics
Zhang, B., Whiteaker, J. R., Hoofnagle, A. N., Baird, G. S., Rodland, K. D., & Paulovich, A. G. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-018-0135-7 · Cited by 210
Complex‐centric proteome profiling by SEC‐SWATH‐MS
Heusel, M., Bludau, I., Rosenberger, G., Hafen, R., Frank, M., Banaei‐Esfahani, A., van Drogen, A., Collins, B. C., Gstaiger, M., & Aebersold, R. (2019) · Molecular Systems Biology · doi:10.15252/msb.20188438 · Cited by 141
Cilento, E. M., Jin, L., Stewart, T., Shi, M., Sheng, L., & Zhang, J. (2019) · Journal of Neurochemistry · doi:10.1111/jnc.14635 · Cited by 60
Metadata
- Authors
- Bourmaud, A., Gallien, S., & Domon, B.
- Venue
- PROTEOMICS
- Publisher
- Wiley
- Published
- 2016-05-27
- Volume
- 16
- Issue
- 15-16
- Pages
- 2146-2159
- ISSN
- 1615-9853 (ISSN-L)
- 1615-9861
- OpenAlex
- W2345735224
- Cited by
- 308
- References
- 47
- FWCI
- 15.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.