The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Triple quadrupole mass spectrometry for direct mixture analysis and structure elucidation
Abstract
The triple quadrupole mass spectrometer is shown to be a simple and highly efficient system for the observation of the fragmentation pattern of selected ions. The instrument consists of, in series, a CI/EI ion source, a quadrupole mass filter, an RF-only quadrupole collision chamber, a second mass filter, and an electron multiplier. The high sensitivity of the MS/MS technique with quadrupoles depends particularly on the highly efficient low energy collision-induced dissociation process in the strong focusing RF quadrupole field. Detection limits for methane and nitrobenzene of 10 to the minus 15 mole are shown. Analysis of a mixture of six components, including two isomers and an isobaric compound is presented. Chemical noise is virtually eliminated by the selection of both parent and fragment ion. An application of the system for structure elucidation is also described. (Author)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
INTERPRETATION OF MASS SPECTRA
(1991) · Analytical Chemistry · doi:10.1021/ac00022a726 · Cited by 1,840
Selected ion fragmentation with a tandem quadrupole mass spectrometer
Yost, R. A., & Enke, C. G. (1978) · Journal of the American Chemical Society · doi:10.1021/ja00475a072 · Cited by 359
Self-citationLevsen, K., & Schwarz, H. (1976) · Angewandte Chemie International Edition in English · doi:10.1002/anie.197605091 · Cited by 242
Kondrat, R. W., McClusky, G. A., & Cooks, R. G. (1978) · Analytical Chemistry · doi:10.1021/ac50036a020 · Cited by 159
Mixture analysis by mass-analyzed ion kinetic energy spectrometry
Kruger, T. L., Litton, J. F., Kondrat, R. W., et al. (1976) · Analytical Chemistry · doi:10.1021/ac50008a016 · Cited by 135
McLafferty, F. W., & Bockhoff, F. M. (1978) · Analytical Chemistry · doi:10.1021/ac50023a021 · Cited by 116
Cited by
Selected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer
Gallien, S., Duriez, E., Crone, C., Kellmann, M., Moehring, T., & Domon, B. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.019802 · Cited by 510
Vidova, V., & Spacil, Z. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.01.059 · Cited by 352
Parallel reaction monitoring using quadrupole‐Orbitrap mass spectrometer: Principle and applications
Bourmaud, A., Gallien, S., & Domon, B. (2016) · PROTEOMICS · doi:10.1002/pmic.201500543 · Cited by 308
Spellman, D. S., Wildsmith, K. R., Honigberg, L. A., Tuefferd, M., Baker, D., Raghavan, N., Nairn, A. C., Croteau, P., Schirm, M., Allard, R., et al. (2015) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201400178 · Cited by 161
Metadata
- Authors
- Yost, R. A., & Enke, C. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1979-10-01
- Volume
- 51
- Issue
- 12
- Pages
- 1251-1264
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1998521509
- Cited by
- 337
- References
- 6
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Triple quadrupole mass spectrometry for direct mixture analysis and structure elucidation. https://app.cochat.ai/papers/10.1021/ac50048a002
- The paper
- Yost, R. A., & Enke, C. G. (1979). Triple quadrupole mass spectrometry for direct mixture analysis and structure elucidation. Analytical Chemistry. https://doi.org/10.1021/ac50048a002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.