CoChat

Absolute Quantification of All Identified Plasma Proteins from SWATH Data for Biomarker Discovery

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

The current state of proteomics requires a choice between targeted and global discovery methods. A method, that combines targeted and data‐independent acquisition for absolute quantification of all identified plasma proteins, in a single sequential window acquisition of all theoretical fragment ions (SWATH) acquisition run, using a panel of spike‐in standards (SIS), is established and optimized. The absolute quantification (AQ) of SWATH and multiple‐reaction monitoring‐high resolution (MRM‐HR) acquisition methods are compared using the 100 protein PlasmaDive SIS panel spiked into non‐depleted human plasma. SWATH provides equivalent quantification and differentially abundant protein profiles as MRM‐HR. Absolute quantities of the SIS peptides from the SWATH data are used to estimate the absolute quantities (eAQ) for all the proteins in the run. The eAQ values provide similar quantification and differentially abundant protein profiles as AQ and protein area (PA) values. As a proof‐of‐concept, the eAQ method is applied to 12 plasma samples from six non‐small cell lung cancer (NSCLC) patients and the performance of eAQ values versus peak area quantification is evaluated. There is a strong correlation between AQ and peak area ratios producing significant overlap of differentially abundant proteins. This eAQ method can provide quantitative data equivalent to AQ or peak area values.

Overview

Integrity signals

Registry

Crossref · 10.1002/pmic.201800135

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Polanski M., 2007, Biomark Insights, 1, 1

Cited by

See all 12

Metadata

Authors
Rice, S. J., Liu, X., Zhang, J., & Belani, C. P.
Affiliations
  • Penn State Cancer Institute (US)
  • Pennsylvania State University (US)
Corresponding author
Belani, Chandra P.
Venue
PROTEOMICS
Publisher
Wiley
Published
2019-01-18
Volume
19
Issue
3
Pages
e1800135-e1800135
ISSN
  • 1615-9853 (ISSN-L)
  • 1615-9861
OpenAlex
W2906282930
Cited by
12
References
38
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 4 · 2020: 3
FWCI
0.76
Type
journal article
Language
en
Open access
closed
Locations
  • PROTEOMICS (publishedVersion)
  • PubMed (publishedVersion)
Funders
Pennsylvania Department of Health
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
absolute quantification, plasma proteins, differentially abundant proteins, non-small cell lung cancer, biomarker discovery, human plasma
MeSH terms
Blood Proteins, Carcinoma, Non-Small-Cell Lung, Humans, Lung Neoplasms, Biomarkers, Tumor, Proteomics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.