Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Clinical relevance using timed walk tests and ‘timed up and go’ testing in persons with Multiple Sclerosis

Nilsagard, Ylva, Lundholm, Cecilia, Gunnarsson, Lars‐Gunnar, Denison, Eva · 2007 · Physiotherapy Research International

Abstract

Background and Purpose. One must understand the potentials and limitations of all tests used to evaluate interventions. The aim of the present study was to clarify the reproducibility, smallest percentage difference needed to be able to detect a genuine change and correlation regarding the 10‐m and 30‐m timed walks (10TW, 30TW) and the ‘timed up and go’ (TUG) test in people with moderate multiple sclerosis (MS). Method. A repeated‐measures design was used, with randomization into two groups and different time intervals used for testing. The 10TW and 30TW were performed three times and TUG twice at each testing. Self‐selected speed was used for 10TW and forced speed (quickly but safely) for 30TW and TUG. Forty‐three people were tested on three occasions within one week. Each person was tested at approximately the same time of the day and by the same physiotherapist on each occasion. Results. The reproducibility was very high. For a single testing occasion, the intraclass correlation was 0.97 for the 10TW and 0.98 for the 30TW and TUG. The smallest percentage difference needed to be able to detect a genuine change in the entire study group was approximately −23% or +31% for either the 10TW or TUG. It was evident from the 30TW testing results that lower values applied to those with less (−14% to +17%) rather than more (−38% or +60%) disability. The correlation between all tests for the entire study group was 0.85 (0.76–0.91). Conclusion. It is sufficient to use only one attempt and to choose only one of the tests when evaluating people with moderate MS. In the case of the 30TW, greater attention must be paid to the degree of disability when determining the smallest percentage difference needed to establish a genuine change, than with either the 10TW or TUG. Copyright © 2007 John Wiley & Sons. Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/pri.358

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Nilsagard, Y., Lundholm, C., Gunnarsson, L., & Denison, E.
Venue
Physiotherapy Research International
Publisher
Wiley
Published
2007-01-16
Volume
12
Issue
2
Pages
105-114
ISSN
  • 1358-2267 (ISSN-L)
  • 1471-2865
OpenAlex
W2039043944
Cited by
210
References
4
FWCI
17.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.