The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Reliability of performance‐based measures in people awaiting joint replacement surgery of the hip or knee
Abstract
Background and Purpose. Understanding the reliability of selected measurement tools is a prerequisite to understanding the effects of clinical interventions. The aim of this investigation was to determine the reliability of the 50‐Foot Timed Walk (50 FTW) and 30‐second Chair Stand Test (30 CST) in subjects awaiting joint replacement surgery of the hip or knee. Methods. Eighty‐two subjects participating in a 6‐week exercise programme were assessed at baseline, 7 weeks and 15 weeks. Four trials of the 50 FTW and two trials of the 30 CST were completed at each assessment. Eleven trained assessors completed the assessments. Results. Intra‐class correlations were consistently high for the 50 FTW and 30 CST at all assessments. At the baseline assessment, trial 1 was found to be significantly different from subsequent trials for both the 50 FTW and 30 CST. This effect was not evident at the 7‐week and 15‐week assessments. At the baseline assessment, scores for the 50 FTW became stable after the first trial. Estimates of minimum detectable change indicated that participants needed to change by more than 3.08 seconds and 1.64 stands to be 90% confident that a real change had occurred for the 50 FTW and 30 CST, respectively. Conclusion. The 50 FTW and 30 CST can be reliable measures of physical performance. However, because we found a practice effect at the baseline assessment, a practice trial should be allowed before data collection begins. Because only two trials of the 30 CST were completed, further research is required to confirm whether scores at the initial assessment become stable on repeated testing. Copyright © 2008 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guralnik, J. M., Simonsick, E. M., Ferrucci, L., Glynn, R. J., Berkman, L. F., Blazer, D. G., Scherr, P. A., & Wallace, R. B. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.2.m85 · Cited by 9,792
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
A 30-s chair-stand test as a measure of lower body strength in community-residing older adults.
Jones, C. J., Rikli, R. E., & Beam, W. C. (1999) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.1999.10608028 · Cited by 2,921
Seeman, T. E., Charpentier, P. A., Berkman, L. F., Tinetti, M. E., Guralnik, J. M., Albert, M., Blazer, D., & Rowe, J. W. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.3.m97 · Cited by 522 · cited 1×
“Other variations of the chairstand test, such as timing 5 or 10 repetitions, have also demonstrated good reliability (Newcomer et al., 1993; Seeman et al., 1994; Hoeymans et al., 1997).”
Cited by
Dobson, F., Hinman, R. S., Roos, E. M., Abbott, J. H., Stratford, P., Davis, A. M., Buchbinder, R., Snyder-Mackler, L., Henrotin, Y., Thumboo, J., et al. (2013) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2013.05.002 · Cited by 908
Bennell, K., Dobson, F., & Hinman, R. (2011) · Arthritis Care & Research · doi:10.1002/acr.20538 · Cited by 463
Dobson, F., Hinman, R. S., Hall, M., Terwee, C. B., Roos, E. M., & Bennell, K. L. (2012) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.08.015 · Cited by 278
Taylor, A. M., Phillips, K., Patel, K. V., Turk, D. C., Dworkin, R. H., Beaton, D., Clauw, D. J., Gignac, M. A. M., Markman, J. D., Williams, D. A., et al. (2016) · Pain · doi:10.1097/j.pain.0000000000000577 · Cited by 208
Liao, C.-D., Tsauo, J.-Y., Huang, S.-W., Ku, J.-W., Hsiao, D.-J., & Liou, T.-H. (2018) · Scientific Reports · doi:10.1038/s41598-018-20677-7 · Cited by 180
Metadata
- Authors
- Gill, S., & McBurney, H.
- Venue
- Physiotherapy Research International
- Publisher
- Wiley
- Published
- 2008-08-12
- Volume
- 13
- Issue
- 3
- Pages
- 141-152
- ISSN
- 1358-2267 (ISSN-L)
- 1471-2865
- OpenAlex
- W1998962486
- Cited by
- 182
- References
- 4
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of performance‐based measures in people awaiting joint replacement surgery of the hip or knee. https://app.cochat.ai/papers/10.1002/pri.411
- The paper
- Gill, S., & McBurney, H. (2008). Reliability of performance‐based measures in people awaiting joint replacement surgery of the hip or knee. Physiotherapy Research International. https://doi.org/10.1002/pri.411
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.