Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 305

The DOI matches its Crossref record.

Peptide sequencing by matrix‐assisted laser‐desorption mass spectrometry

Spengler, Bernhard, Kirsch, Dieter, Kaufmann, Raimund, Jaeger, Ernst·1992·Rapid Communications in Mass Spectrometry

Abstract

A novel method of peptide sequencing by mass spectrometry is described. Metastable decay of laser‐desorbedions, taking place in the first field‐free drift region of a reflectron time‐of‐flight mass spectrometer, has been monitored to get structural information from larger peptides. Fragment ions from metastable decay are mass analysed by adjusting the potentiaals of the ion reflectron according to the kinetic energies of the ions. The features of the technique and its significance for future applications are outlined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.1290060207

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Spengler, B., Kirsch, D., Kaufmann, R., & Jaeger, E.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
1992-02
Volume
6
Issue
2
Pages
105-108
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W1968904921
Cited by
305
References
0
FWCI
10.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Peptide sequencing by matrix‐assisted laser‐desorption mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.1290060207
The paper
Spengler, B., Kirsch, D., Kaufmann, R., & Jaeger, E. (1992). Peptide sequencing by matrix‐assisted laser‐desorption mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1290060207

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.