Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 295

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Protease‐catalyzed incorporation of 18O into peptide fragments and its application for protein sequencing by electrospray and matrix‐assisted laser desorption/ionization mass spectrometry

Schnölzer, Martina, Jedrzejewski, Paul, Lehmann, Wolf D.·1996·ELECTROPHORESIS

Abstract

Proteins were digested in normal and highly 18 O‐enriched water using proteases commonly employed for protein sequencing. The extent of 18 O incorporation into the resulting peptide fragments was characterized by electrospray ionization (ESI) and matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry (MS). The endoproteinases trypsin, Lys‐C and Glu‐C incorporate two atoms of 18 O, resulting in a mass shift of +4 D for the peptide fragments. This indicates that, following proteolytic cleavage, peptide products continue to interact with these proteases and undergo repeated binding/hydrolysis cycles, resulting in complete equilibration of both oxygens in the carboxy terminus of the fragments with oxygen from solvent water. In contrast, chymotrypsin and Asp‐N incorporate only one atom of 18 O, resulting in a mass shift of +2 D, indicating that after the cleavage step these proteases do not accept the peptides as substrates. In addition, it was found that the proteases trypsin, Glu‐C, and Lys‐C exhibit minor or nontypical sequence specificities, resulting in unexpected peptide fragments. These fragments incorporate only one 18 O atom, indicating that they do not undergo further binding/hydrolysis cycles with the enzyme. Thus, it is possible to discriminate between enzyme‐typical peptide fragments with mass shifts of +4 D and nontypical fragments with mass shifts of only +2 D. Based on these observations, protein digest strategies are described for the generation of 1:1 ion doublets spaced either by 2 or 4 D. In addition, the C‐terminus of a protein can be identified by the absence of an ion doublet in the corresponding peptide fragment. In protein sequencing by mass spectrometry, digest protocols generating ion doublets provide the most clear‐cut analytical results for the recognition of ion series in ESI‐MS/MS and MALDI post‐source decay (PSD) product ion specta. Only the mass spectrometric fragment ions of a C‐terminal series show ion doublets spaced either by 2 or 4 D, whereas the fragment ions belonging to an N‐terminal series remain unshifted. This assignment unequivocally reveals the direction of the identified sequence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/elps.1150170517

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 295

Metadata

Authors
Schnölzer, M., Jedrzejewski, P., & Lehmann, W. D.
Venue
ELECTROPHORESIS
Publisher
Wiley
Published
1996-01
Volume
17
Issue
5
Pages
945-953
ISSN
  • 0173-0835 (ISSN-L)
  • 1522-2683
OpenAlex
W2016707540
Cited by
295
References
5
FWCI
4.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Protease‐catalyzed incorporation of 18O into peptide fragments and its application for protein sequencing by electrospray and matrix‐assisted laser desorption/ionization mass spectrometry. https://app.cochat.ai/papers/10.1002/elps.1150170517
The paper
Schnölzer, M., Jedrzejewski, P., & Lehmann, W. D. (1996). Protease‐catalyzed incorporation of 18O into peptide fragments and its application for protein sequencing by electrospray and matrix‐assisted laser desorption/ionization mass spectrometry. ELECTROPHORESIS. https://doi.org/10.1002/elps.1150170517

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.