The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Disentangling electrospray spectra with maximum entropy
Abstract
Software using maximum entropy (MaxEnt) analysis has been developed, and used to econvolute complete electrospray spectra of protein mixtures. It automatically produces zero‐charge mass spectra on a molecular mass scale, along with probabilistic quantification so that the reliability of features in the spectrum can be ascertained. Because maximum entropy is faithful to the experimental data, the results tend to have improved resolution and signal‐to‐noise ratio. This improved performance, particularly regarding resolution, is demonstrated on a haemoglobin containing two β‐globins separated by 12 Da at m / z 15 867 (0.08%). A separation of 12 Da was previously the closest at which mass measurement of two globins was practicable. Also, two hiherto unresolved β‐globins from a second haemoglobin, separated by 9 Da (0.06%) were resolved by MaxEnt and their masses accurately measured. These are the first results using rigorous MaxEnt analysis in electrospray mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
Hemoglobin: Molecular, genetic and clinical aspects
Nienhuis, A. W. (1987) · Cell · doi:10.1016/0092-8674(87)90069-9 · Cited by 230
Skilling, J. (1988) · Maximum-Entropy and Bayesian Methods in Science and Engineering · doi:10.1007/978-94-009-3049-0_8 · Cited by 191
Self-citationMaximum entropy deconvolution in electrospray mass spectrometry
Ferrige, A. G., Seddon, M. J., Jarvis, S. A., Skilling, J., & Aplin, R. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050810 · Cited by 155
Self-citationWitkowska, H. E., Lubin, B. H., Beuzard, Y., Baruchel, S., Esseltine, D. W., Vichinsky, E. P., Kleman, K. M., Bardakdjian‐Michau, J., Pinkoski, L., Cahn, S., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199110173251607 · Cited by 58
Self-citation
Cited by
INTERPRETATION OF MASS SPECTRA
(1991) · Analytical Chemistry · doi:10.1021/ac00022a726 · Cited by 1,840
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Zhang, Z., & Marshall, A. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00284-5 · Cited by 509
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Metadata
- Authors
- Ferrige, A. G., Seddon, M. J., Green, B. N., Jarvis, S. A., Skilling, J., & Staunton, J.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1992-11
- Volume
- 6
- Issue
- 11
- Pages
- 707-711
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2140550847
- Cited by
- 261
- References
- 5
- FWCI
- 6.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Disentangling electrospray spectra with maximum entropy. https://app.cochat.ai/papers/10.1002/rcm.1290061115
- The paper
- Ferrige, A. G., Seddon, M. J., Green, B. N., Jarvis, S. A., Skilling, J., & Staunton, J. (1992). Disentangling electrospray spectra with maximum entropy. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1290061115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.