Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.

Best practices and benchmarks for intact protein analysis for top-down mass spectrometry

Open access

Abstract

One gene can give rise to many functionally distinct proteoforms, each of which has a characteristic molecular mass. Top-down mass spectrometry enables the analysis of intact proteins and proteoforms. Here members of the Consortium for Top-Down Proteomics provide a decision tree that guides researchers to robust protocols for mass analysis of intact proteins (antibodies, membrane proteins and others) from mixtures of varying complexity. We also present cross-platform analytical benchmarks using a protein standard sample, to allow users to gauge their proficiency. The Consortium for Top-Down Proteomics presents a decision-tree-based guide to sample preparation and analysis protocols for researchers performing top-down mass-spectrometry-based analysis of intact proteins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41592-019-0457-0

Cites

68 of 68 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Common buffer components suppress MS signal. a, MgCl2 reduces signal (and S/N) in a concentration-dependent manner. b, Fit of experimental data to determine the concentration of MgCl2 required for 50% signal suppression (SC50; black arrow), c, Table of common buffer components and the concentration threshold for 50% SC50 (experimental data curves and their fits are shown in Supplementary Fig. 1) and calculations in Supplementary Note 2. Detergents compatible with mass spectrometry are discussed in Protocol 2b. *Signal suppression by detergents is less pronounced above their critical micellar concentration (CMC) (described in Protocol 2b).
Fig. 1 Common buffer components suppress MS signal. a, MgCl2 reduces signal (and S/N) in a concentration-dependent manner. b, Fit of experimental data to determine the concentration of MgCl2 required for 50% signal suppression (SC50; black arrow), c, Table of common buffer components and the concentration threshold for 50% SC50 (experimental data curves and their fits are shown in Supplementary Fig. 1) and calculations in Supplementary Note 2. Detergents compatible with mass spectrometry are discussed in Protocol 2b. *Signal suppression by detergents is less pronounced above their critical micellar concentration (CMC) (described in Protocol 2b).CC BY · PubMed Central
Fig. 2 Decision tree for intact protein sample clean-up, preparation and analysis. The red dashed line, for example, denotes the decision path for the native MS analysis of a membrane protein. *LC can also be applied at this stage in the decision tree. †Minimally complex protein samples prepared following Protocol 3 can be analyzed via denaturing direct infusion (Protocol 4a) if desired. Supplementary Fig. 2 (SF.2) shows a recommended example of 2D separation following the GELFrEE protocol. ‡Other viable alternative separation techniques include capillary zone electrophoresis, ion exchange and size exclusion chromatography.
Fig. 2 Decision tree for intact protein sample clean-up, preparation and analysis. The red dashed line, for example, denotes the decision path for the native MS analysis of a membrane protein. *LC can also be applied at this stage in the decision tree. †Minimally complex protein samples prepared following Protocol 3 can be analyzed via denaturing direct infusion (Protocol 4a) if desired. Supplementary Fig. 2 (SF.2) shows a recommended example of 2D separation following the GELFrEE protocol. ‡Other viable alternative separation techniques include capillary zone electrophoresis, ion exchange and size exclusion chromatography.CC BY · PubMed Central
Fig. 3 Dilution (Protocol 1), MWCO ultrafiltration (Protocol 2a) and precipitation (Protocol 3) sample preparation protocols applied to common buffers. a,b, Protein standard mixture in PBS (a) and detergent-containing RIPA buffer (b). In the buffer containing harsh detergents, protein signal is attained only with precipitation. c, NISTmAb in 12.5 mM L-histidine, 12.5 mM L-histidine HCl (pH 6.0). Mass spectra were obtained using a Fourier transform ion cyclotron resonance MS (FT-ICR) (Bruker Daltronics SolariX 9.4T MS) using denaturing direct infusion (Protocol 4a). See Supplementary Fig. 3 for additional results with ‘gentle elution’ immunoaffinity elution buffer and a second antibody buffer.
Fig. 3 Dilution (Protocol 1), MWCO ultrafiltration (Protocol 2a) and precipitation (Protocol 3) sample preparation protocols applied to common buffers. a,b, Protein standard mixture in PBS (a) and detergent-containing RIPA buffer (b). In the buffer containing harsh detergents, protein signal is attained only with precipitation. c, NISTmAb in 12.5 mM L-histidine, 12.5 mM L-histidine HCl (pH 6.0). Mass spectra were obtained using a Fourier transform ion cyclotron resonance MS (FT-ICR) (Bruker Daltronics SolariX 9.4T MS) using denaturing direct infusion (Protocol 4a). See Supplementary Fig. 3 for additional results with ‘gentle elution’ immunoaffinity elution buffer and a second antibody buffer.CC BY · PubMed Central
Fig. 4 Denatured versus native ESI-MS of carbonic anhydrase. Intensity is scaled to demonstrate the difference between denaturing MS (left) and native MS (right). These spectra were collected on the same instrument using the same concentration (10 µM). Native MS results in lower and fewer charge states, and thus the signals have higher intensity and appear at a higher m/z. The inset includes the most abundant charge state and the S/N.
Fig. 4 Denatured versus native ESI-MS of carbonic anhydrase. Intensity is scaled to demonstrate the difference between denaturing MS (left) and native MS (right). These spectra were collected on the same instrument using the same concentration (10 µM). Native MS results in lower and fewer charge states, and thus the signals have higher intensity and appear at a higher m/z. The inset includes the most abundant charge state and the S/N.CC BY · PubMed Central
Fig. 5 LC-MS of protein standard mixture prepared following Protocol 5a and separated on a Dionex UPLC with a Thermo Orbitrap Elite system using PLRP-S stationary phase. Final concentrations of each protein loaded onto the column were 0.14 pmol ubiquitin, 0.49 pmol trypsinogen, 1.09 pmol myoglobin and 0.64 pmol carbonic anhydrase (top). Summary of S/N values calculated for each protein on all instrumentation platforms using the given SOP (bottom) including Dionex Ultimate 3000–Thermo Orbitrap Elite, Waters Acquity–Xevo G2-S QTOF, Waters nanoAcquity–Bruker Impact II QTOF, Waters nanoAcquity–Bruker SolariX FT-ICR, Dionex Ultimate 3000–Thermo Fusion Lumos, and Dionex Ultimate 3000–Thermo QE-HF. As described, S/N calculations differ per manufacturer and do not reflect absolute performance.
Fig. 5 LC-MS of protein standard mixture prepared following Protocol 5a and separated on a Dionex UPLC with a Thermo Orbitrap Elite system using PLRP-S stationary phase. Final concentrations of each protein loaded onto the column were 0.14 pmol ubiquitin, 0.49 pmol trypsinogen, 1.09 pmol myoglobin and 0.64 pmol carbonic anhydrase (top). Summary of S/N values calculated for each protein on all instrumentation platforms using the given SOP (bottom) including Dionex Ultimate 3000–Thermo Orbitrap Elite, Waters Acquity–Xevo G2-S QTOF, Waters nanoAcquity–Bruker Impact II QTOF, Waters nanoAcquity–Bruker SolariX FT-ICR, Dionex Ultimate 3000–Thermo Fusion Lumos, and Dionex Ultimate 3000–Thermo QE-HF. As described, S/N calculations differ per manufacturer and do not reflect absolute performance.CC BY · PubMed Central
Fig. 6 LC-MS of bacteriorhodopsin-containing purple membrane of H. salinarum prepared following Protocol 5b and analyzed on an Agilent HPLC system coupled to a Thermo linear ion trap (LTQ) mass spectrometer. Proteins were separated using an Agilent PLRP-S 300 Å, 2.1 × 150 mm, 3 µm. Supplementary Fig. 12 demonstrates this analysis on four additional instrumentation platforms.
Fig. 6 LC-MS of bacteriorhodopsin-containing purple membrane of H. salinarum prepared following Protocol 5b and analyzed on an Agilent HPLC system coupled to a Thermo linear ion trap (LTQ) mass spectrometer. Proteins were separated using an Agilent PLRP-S 300 Å, 2.1 × 150 mm, 3 µm. Supplementary Fig. 12 demonstrates this analysis on four additional instrumentation platforms.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 68 references

Cited by

See all 408

Metadata

Authors
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., Lantz, C., Jung, W., Johnson, K. R., Koller, A., Wolff, J. J., Campuzano, I. D. G., Auclair, J. R., Ivanov, A. R., Whitelegge, J. P., Paša-Tolić, L., Chamot-Rooke, J., Danis, P. O., Smith, L. M., Tsybin, Y. O., Loo, J. A., Ge, Y., Kelleher, N. L., & Agar, J. N.
Affiliations
  • Northeastern University (US)
  • Northwestern University (US)
  • University of Wisconsin–Madison (US)
  • Amgen (United States) (US)
  • University of California, Los Angeles (US)
  • Bruker (United States) (US)
  • Spectroswiss (Switzerland) (CH)
Corresponding author
Agar, Jeffrey N.
Venue
Nature Methods
Published
2019-06-27
Volume
16
Issue
7
Pages
587-594
ISSN
  • 1548-7091 (ISSN-L)
  • 1548-7105
OpenAlex
W2954182729
Cited by
377
References
68
Citations by year
2026: 37 · 2025: 45 · 2024: 55 · 2023: 50 · 2022: 62 · 2021: 70 · 2020: 46 · 2019: 10
FWCI
4.75
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Methods (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, cc-by)
  • eScholarship (California Digital Library) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • LillOA (Université de Lille (University Of Lille)) (submittedVersion, other-oa)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Funders
  • U.S. Department of Energy (DEFC0202ER63421)
  • ALS Association (18-IIA-420)
  • Amgen
  • Northwestern University
  • National Institutes of Health (1s10od018504-01, NIH-R01, 1s10od018475-01)
  • National Cancer Institute (R01CA218500)
  • National Institute of General Medical Sciences (GM 007185, NIH R01 GM117058, P41GM108569, GM117058, R01GM103479, R01GM117058, GM103479, R01GM120272, T32GM105538, T32GM007185)
  • National Institute of Diabetes and Digestive and Kidney Diseases (P30DK063491)
  • National Institute of Neurological Disorders and Stroke (R01NS065263)
  • National Center for Research Resources (S10RR028893)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
top-down mass spectrometry, top-down proteomics, proteoforms, decision tree, sample preparation protocol, protein standards, immunoglobulins, membrane proteins
MeSH terms
Protein Denaturation, Protein Processing, Post-Translational, Proteins, Mass Spectrometry, Benchmarking, Proteomics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Best practices and benchmarks for intact protein analysis for top-down mass spectrometry. https://app.cochat.ai/papers/10.1038/s41592-019-0457-0
The paper
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., Lantz, C., Jung, W., Johnson, K. R., Koller, A., Wolff, J. J., Campuzano, I. D. G., Auclair, J. R., Ivanov, A. R., Whitelegge, J. P., . . . Agar, J. N. (2019). Best practices and benchmarks for intact protein analysis for top-down mass spectrometry. Nature Methods. https://doi.org/10.1038/s41592-019-0457-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.