The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Delayed extraction matrix‐assisted laser desorption time‐of‐flight mass spectrometry
Abstract
A new delayed extraction matrix‐assisted laser desorption/ionization (MALDI) time‐of‐flight (TOF) mass spectrometer system is described which provides dramatically improved performance over that obtained with identical TOF analyzers operated with constant electrical fields. In this system the ions formed by MALDI are produced in a weak electrical field, and subsequently extracted by application of a high voltage pulse after a predetermined time delay. Three parameters can be independently adjusted to optimize the performance. These include the field magnitude and direction during and immediately following ion production, the magnitude of the extraction field, and the time delay between the laser pulse and application of the extraction field. Theoretical equations are presented which guide the selection of these parameters to optimize the performance. Results are presented from three TOF analyzers of similar design, but ranging in size from a 1.3 m linear analyzer to a 6.4 m reflector. In all cases delayed extraction provides substantially improved resolution over that obtained from static operation. In the smallest linear analyzer resolution of M/ΔM (full width at half maximum) of 4000 is demonstrated for angiotensin I, and with the largest reflecting analyzer, the isotope peaks of bovine insulin are resolved nearly to baseline. With larger proteins, the isotopic peaks are not resolved, but resolution approaching the width of the isotopic envelope is obtained. Resolution improvement is demonstrated for proteins up to 30 kDa. In addition to improved resolution, delayed extraction is shown to improve the quality of MALDI mass spectra by suppressing matrix background, reducing chemical noise, and minimizing the effect of laser intensity on performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-of-Flight Mass Spectrometer with Improved Resolution
Wiley, W. C., & McLaren, I. H. (1955) · Review of Scientific Instruments · doi:10.1063/1.1715212 · Cited by 3,678
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
New approach to the mass spectroscopy of non-volatile compounds
Torgerson, D. F., Skowronski, R. P., & Macfarlane, R. D. (1974) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(74)90285-x · Cited by 466
Hillenkamp, F., & Karas, M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93420-p · Cited by 375
Brown, R. S., & Lennon, J. J. (1995) · Analytical Chemistry · doi:10.1021/ac00109a015 · Cited by 371
Beavis, R. C., & Chait, B. T. (1991) · Chemical Physics Letters · doi:10.1016/0009-2614(91)90384-l · Cited by 269
Verentchikov, A. N., Ens, W., & Standing, K. G. (1994) · Analytical Chemistry · doi:10.1021/ac00073a022 · Cited by 223
Whittal, R. M., & Li, L. (1995) · Analytical Chemistry · doi:10.1021/ac00109a007 · Cited by 172
Matrix Dependence of Metastable Fragmentation of Glycoproteins in MALDI TOF Mass Spectrometry
Karas, M., Bahr, U., Strupat, K., Hillenkamp, F., Tsarbopoulos, A., & Pramanik, B. N. (1995) · Analytical Chemistry · doi:10.1021/ac00099a029 · Cited by 169
Cited by
Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Clauser, K. R., Baker, P., & Burlingame, A. L. (1999) · Analytical Chemistry · doi:10.1021/ac9810516 · Cited by 1,093
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Matrix-assisted laser desorption/ionization mass spectrometry of carbohydrates
Harvey, D. J. (1999) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1999)18:6<349::aid-mas1>3.0.co;2-h · Cited by 725
An introduction to quadrupole–time‐of‐flight mass spectrometry
Chernushevich, I. V., Loboda, A. V., & Thomson, B. A. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.207 · Cited by 705
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Ion Formation in MALDI: The Cluster Ionization Mechanism
Karas, M., & Krüger, R. (2003) · Chemical Reviews · doi:10.1021/cr010376a · Cited by 651
Karas, M., Gl�ckmann, M., & Sch�fer, J. (2000) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(200001)35:1<1::aid-jms904>3.0.co;2-0 · Cited by 614
Griffith, E. C., Su, Z., Turk, B. E., Chen, S., Chang, Y.-H., Wu, Z., Biemann, K., & Liu, J. O. (1997) · Chemistry & Biology · doi:10.1016/s1074-5521(97)90198-8 · Cited by 421
Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
Laiko, V. V., Baldwin, M. A., & Burlingame, A. L. (2000) · Analytical Chemistry · doi:10.1021/ac990998k · Cited by 411
High level multiplex genotyping by MALDI-TOF mass spectrometry
Ross, P., Hall, L., Smirnov, I., & Haff, L. (1998) · Nature Biotechnology · doi:10.1038/4328 · Cited by 408
Küster, B., Wheeler, S. F., Hunter, A. P., Dwek, R. A., & Harvey, D. J. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2199 · Cited by 358
Protein identification methods in proteomics
Gevaert, K., & Vandekerckhove, J. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1145::aid-elps1145>3.0.co;2-z · Cited by 338
Orthogonal acceleration time-of-flight mass spectrometry
Guilhaus, M., Selby, D., & Mlynski, V. (2000) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(2000)19:2<65::aid-mas1>3.0.co;2-e · Cited by 338
Mass spectrometry of nucleic acids
Nordhoff, E., Kirpekar, F., & Roepstorff, P. (1996) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1996)15:2<67::aid-mas1>3.0.co;2-8 · Cited by 315
Swords, W. E., Buscher, B. A., Ver Steeg Ii, K., Preston, A., Nichols, W. A., Weiser, J. N., Gibson, B. W., & Apicella, M. A. (2000) · Molecular Microbiology · doi:10.1046/j.1365-2958.2000.01952.x · Cited by 310
Phosphopeptide Analysis by Matrix-Assisted Laser Desorption Time-of-Flight Mass Spectrometry
Annan, R. S., & Carr, S. A. (1996) · Analytical Chemistry · doi:10.1021/ac960221g · Cited by 310
Loboda, A. V., Krutchinsky, A. N., Bromirski, M., Ens, W., & Standing, K. G. (2000) · Rapid Communications in Mass Spectrometry · doi:10.1002/1097-0231(20000630)14:12<1047::aid-rcm990>3.0.co;2-e · Cited by 305
Sample Preparation Methods for Mass Spectrometric Peptide Mapping Directly from 2-DE Gels
Jensen, O. N., Wilm, M., Shevchenko, A., & Mann, M. (2003) · 2-D Proteome Analysis Protocols · doi:10.1385/1-59259-584-7:513 · Cited by 305
Strategies for analysis of glycoprotein glycosylation
Geyer, H., & Geyer, R. (2006) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2006.10.007 · Cited by 299
Qiu, Y., Benet, L. Z., & Burlingame, A. L. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.28.17940 · Cited by 298
MALDI Quadrupole Time-of-Flight Mass Spectrometry: A Powerful Tool for Proteomic Research
Shevchenko, A., Loboda, A., Shevchenko, A., Ens, W., & Standing, K. G. (2000) · Analytical Chemistry · doi:10.1021/ac9913659 · Cited by 290
Schilling, B., Row, R. H., Gibson, B. W., Guo, X., & Young, M. M. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00327-1 · Cited by 278
Papac, D. I., Wong, A., & Jones, A. J. S. (1996) · Analytical Chemistry · doi:10.1021/ac960324z · Cited by 277
Proteomics in Diagnostic Pathology
Chaurand, P., Sanders, M. E., Jensen, R. A., & Caprioli, R. M. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63367-6 · Cited by 253
Lim, A., Prokaeva, T., McComb, M. E., O'Connor, P. B., Théberge, R., Connors, L. H., Skinner, M., & Costello, C. E. (2002) · Analytical Chemistry · doi:10.1021/ac010780+ · Cited by 63
Metadata
- Authors
- Vestal, M. L., Juhasz, P., & Martin, S. A.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 9
- Issue
- 11
- Pages
- 1044-1050
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2135842532
- Cited by
- 497
- References
- 13
- FWCI
- 32.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.