A simple, rapid and sensitive method for determination of aldehydes in human blood by gas chromatography/mass spectrometry and solid‐phase microextraction with on‐fiber derivatization
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aldehydes are considered potential markers for enhanced oxidative stress and have been proposed as a diagnostic measure of cancer status. Duo to their volatility and activity, it is very difficult to accurately measure aldehydes in human blood. In the present work, gas chromatography/mass spectrometry (GC/MS) and solid‐phase microextraction (SPME) with on‐fiber derivatization was developed for determination of aldehydes in human blood. O ‐(2,3,4,5,6‐Pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) in aqueous solution was first adsorbed by a SPME fiber, and then the aldehydes in blood samples were headspace extracted by the SPME fiber and rapidly derivatized with PFBHA on the SPME fiber. Finally, the oximes formed were desorbed and detected by GC/MS in electron ionization (EI) mode. Validation of the present method was carried out, and the method was applied to quantitative analysis of the aldehydes in lung cancer blood. The results demonstrated that GC/MS and SPME with on‐fiber derivatization is a simple, rapid, sensitive and solvent‐free method for the determination of aldehydes in human blood. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Persistent oxidative stress in cancer
Toyokuni, S., Okamoto, K., Yodoi, J., & Hiai, H. (1995) · FEBS Letters · doi:10.1016/0014-5793(94)01368-b · Cited by 1,219
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
“Skin secretions [4, 149–155, 157, 158, 222, 223]; milk [17, 24, 168, 170–173, 175, 176]; blood [122–127, 130, 134, 136, 145, 183, 224–230]; saliva [154, 160, 161, 163, 165, 231–233].”
Current Challenges in Volatile Organic Compounds Analysis as Potential Biomarkers of Cancer
Schmidt, K., & Podmore, I. (2015) · Journal of Biomarkers · doi:10.1155/2015/981458 · Cited by 208
“A different approach to the issue of the possible exogenous origin of proposed VOC biomarkers focuses on the detection of aldehydes [12, 59, 65, 96] or hydrocarbons [97–99] only as markers of cancer.”
BackgroundApplication of solid-phase microextraction in analytical toxicology
Pragst, F. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1289-9 · Cited by 198
Lili, L., Xu, H., Song, D., Cui, Y., Hu, S., & Zhang, G. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.081 · Cited by 123
Xu, H., Song, D., Cui, Y., Hu, S., Yu, Q.-W., & Feng, Y.-Q. (2009) · Chromatographia · doi:10.1365/s10337-009-1208-7 · Cited by 37
Metadata
- Authors
- Deng, C., & Zhang, X.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2004-06-29
- Volume
- 18
- Issue
- 15
- Pages
- 1715-1720
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2152280524
- Cited by
- 70
- References
- 1
- FWCI
- 5.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple, rapid and sensitive method for determination of aldehydes in human blood by gas chromatography/mass spectrometry and solid‐phase microextraction with on‐fiber derivatization. https://app.cochat.ai/papers/10.1002/rcm.1544
- The paper
- Deng, C., & Zhang, X. (2004). A simple, rapid and sensitive method for determination of aldehydes in human blood by gas chromatography/mass spectrometry and solid‐phase microextraction with on‐fiber derivatization. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.1544
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.