CoChat

Quantification of human insulin‐like growth factor‐1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionisation tandem mass spectrometry

Open access
Bredehöft, Michael, Schänzer, Wilhelm, Thevis, Mario · 2008 · Rapid Communications in Mass Spectrometry
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Human insulin‐like growth factor‐1 (IGF‐1) is a peptide hormone that acts as a mediator of most of the somatotropic effects of growth hormone (GH). Therefore, it is supposed to be a biomarker indicating GH abuse in sports as well as diseases associated with a change in IGF‐1 plasma concentration. It can be applied locally by injection to increase total protein and DNA content in tissues such as skeletal muscle – a highly desirable effect in various sports disciplines. In order to improve its growth‐promoting properties, the primary structure of IGF‐1 has been modified, yielding analogues such as des(1‐3)IGF‐1 and LONG™R 3 IGF‐1, which show a considerably reduced affinity to the respective binding proteins in plasma and, thus, an increased bioavailability at target tissues. Due to their capability to enhance performance, IGF‐1 and its analogues belong to the prohibited list of the World Anti‐Doping Agency. Hence, it was necessary to develop a reliable assay for the quantification of human IGF‐1 as well as the detection of its derivatives. Immunoaffinity isolation and purification from 60 µL of plasma followed by liquid chromatography/electrospray ionisation tandem mass spectrometry enabled the unequivocal determination of all target analytes. Diagnostic product ions were characterised utilising an Orbitrap mass spectrometer with high resolution/high accuracy properties and employed for triple quadrupole MS/MS analysis. The described assay provided lower limits of detection (LLODs) between 20 and 50 ng/mL, recovery rates between 34–43% and a precision <15% at the LLOD as well as higher concentration levels. In order to prove the applicability of the developed assay, human plasma samples were analysed and the results were compared with the values obtained from a commercially available immunoradiometric assay (IRMA). Four of six samples resulted in concentration ratios with good correlation between both assays, whereas the absolute concentrations were lower for the presented procedure. Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.3388

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 107

Metadata

Authors
Bredehöft, M., Schänzer, W., & Thevis, M.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2008-01-30
Volume
22
Issue
4
Pages
477-485
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2099306792
Cited by
107
References
1
FWCI
54.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantification of human insulin‐like growth factor‐1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionisation tandem mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.3388
The paper
Bredehöft, M., Schänzer, W., & Thevis, M. (2008). Quantification of human insulin‐like growth factor‐1 and qualitative detection of its analogues in plasma using liquid chromatography/electrospray ionisation tandem mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.3388

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.