Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Determination of 13 C/ 12 C ratios of endogenous urinary steroids: method validation, reference population and application to doping control purposes

Piper, Thomas, Mareck, Ute, Geyer, Hans, Flenker, Ulrich, Thevis, Mario, Platen, Petra, Schänzer, Wilhelm·2008·Rapid Communications in Mass Spectrometry

Abstract

The application of a comprehensive gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS)‐based method for stable carbon isotopes of endogenous urinary steroids is presented. The key element in sample preparation is the consecutive cleanup with high‐performance liquid chromatography (HPLC) of underivatized and acetylated steroids, which allows the isolation of ten analytes (11 β ‐hydroxyandrosterone, 5 α ‐androst‐16‐en‐3 β ‐ol, pregnanediol, androsterone, etiocholanolone, testosterone, epitestosterone, 5 α ‐androstane‐3 α ,17 β ‐diol, 5 β ‐androstane‐3 α ,17 β ‐diol and dehydroepiandrosterone) from a single urine specimen. These steroids are of particular importance to doping controls as they enable the sensitive and retrospective detection of steroid abuse by athletes. Depending on the biological background, the determination limit for all steroids ranges from 5 to 10 ng/mL for a 10 mL specimen. The method is validated by means of linear mixing models for each steroid, which covers repeatability and reproducibility. Specificity was further demonstrated by gas chromatography/mass spectrometry (GC/MS) for each analyte, and no influence of the sample preparation or the quantity of analyte on carbon isotope ratios was observed. In order to determine naturally occurring 13 C/ 12 C ratios of all implemented steroids, a reference population of n = 61 subjects was measured to enable the calculation of reference limits for all relevant steroidal Δ values. Copyright © 2008 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.3601

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Piper, T., Mareck, U., Geyer, H., Flenker, U., Thevis, M., Platen, P., & Schänzer, W.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2008-06-06
Volume
22
Issue
14
Pages
2161-2175
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2112628426
Cited by
169
References
1
FWCI
51.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of 13 C/ 12 C ratios of endogenous urinary steroids: method validation, reference population and application to doping control purposes. https://app.cochat.ai/papers/10.1002/rcm.3601
The paper
Piper, T., Mareck, U., Geyer, H., Flenker, U., Thevis, M., Platen, P., & Schänzer, W. (2008). Determination of 13 C/ 12 C ratios of endogenous urinary steroids: method validation, reference population and application to doping control purposes. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.3601

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.