A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometry
The DOI matches its Crossref record.
Abstract
A graphite‐polyimide mixture was used as a conductive coating for sheathless electrospray emitters. The coating procedure described is simple and inexpensive compared to previously described methods. An investigation of the stability of the conductive coating carried out by electrochemical methods revealed good performances during oxidative stress. In addition, no decrease in emitter performance was seen during continuous electrospray in the positive electrospray mode for two weeks. Fast capillary electrophoresis with attomole sensitivity demonstrated the excellent performance of the described sheathless interface when used in conjunction with an orthogonal time‐of‐flight mass spectrometer. The overall simplicity, stability and low cost of this type of sheathless emitter make the described approach highly suitable for any on‐column coupling of low flow rate separation techniques to a mass spectrometer. Copyright © 2001 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kolch, W., Neusüß, C., Pelzing, M., & Mischak, H. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20051 · Cited by 290
Capillary electrophoresis – mass spectrometry: 15 years of developments and applications
Schmitt‐Kopplin, P., & Frommberger, M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305659 · Cited by 289
Capillary electrophoresis applied to proteomic analysis
Fonslow, B. R., & Yates III, J. R. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800592 · Cited by 92
Quantitative Proteomics Using Ultralow Flow Capillary Electrophoresis–Mass Spectrometry
Faserl, K., Kremser, L., Müller, M., Teis, D., & Lindner, H. H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00312 · Cited by 57
Guo, X., Fillmore, T. L., Gao, Y., & Tang, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04912 · Cited by 54
Metadata
- Authors
- Nilsson, S., Wetterhall, M., Bergquist, J., Nyholm, L., & Markides, K. E.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2001-10-04
- Volume
- 15
- Issue
- 21
- Pages
- 1997-2000
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1981561723
- Cited by
- 110
- References
- 0
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometry. https://app.cochat.ai/papers/10.1002/rcm.466
- The paper
- Nilsson, S., Wetterhall, M., Bergquist, J., Nyholm, L., & Markides, K. E. (2001). A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.466
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.