Determination of vitamins A, D and E in a small volume of human plasma by a high‐throughput method based on liquid chromatography/tandem mass spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We have developed an automated high‐throughput assay for the determination of vitamin A (retinol), ergocalciferol (25‐OH D2), cholecalciferol (25‐OH D3) and vitamin E (α‐tocopherol) in a small volume of human plasma. Sample preparation involved mixing 50 μL of plasma with 100 μL of ethanol containing isotope‐labelled internal standards, followed by mixing with isooctane/chloroform (3:1, 300 μL). The organic phase was evaporated, and the sample reconstituted in 50 μL methanol. The analysis was performed using reversed‐phase liquid chromatography with a gradient mobile phase containing water, methanol and ammonium formate. Chromatographic run‐time was 5 min, and positive mode electrospray tandem mass spectrometry (MS/MS) was used for detection. The limits of detection were 0.10 μM for all‐trans retinol and 3.3 nM for 25‐OH D2 and 25‐OH D3. Recoveries were 91.9–105.0%, and within‐ and between‐day coefficients of variance (CVs) 2.4–5.3 and 3.1–8.2, respectively. The assay is presently being used in large‐scale studies. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mata-Granados, J. M., Luque de Castro, M. D., & Quesada, J. M. (2004) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2004.01.027 · Cited by 45
Cited by
Janoušek, J., Pilařová, V., Macáková, K., Nomura, A., Veiga-Matos, J., Silva, D. D. D., Remião, F., Saso, L., Malá-Ládová, K., Malý, J., et al. (2022) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2022.2070595 · Cited by 233
Zhang, Y., Zhou, W.-E., Yan, J.-Q., Liu, M., Zhou, Y., Shen, X., Ma, Y.-L., Feng, X.-S., Yang, J., & Li, G.-H. (2018) · Molecules · doi:10.3390/molecules23061484 · Cited by 166
“3 nM for 25-OH VD2 and 25-OH VD3 no report [64]”
BackgroundInfluentialEfficacy of fish intake on Vitamin D status: A meta-analysis of randomized controlled trials
Lehmann, U., Gjessing, H. R., Hirche, F., Mueller-Belecke, A., Gudbrandsen, O. A., Ueland, P. M., Mellgren, G., Lauritzen, L., Lindqvist, H., Hansen, A. L., et al. (2015) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.114.105395 · Cited by 100
“Fasting blood samples were collected at baseline and after 4 wk, and 25(OH)D was determined in serum by LC-MS/MS according to methods of Midttun and Ueland (45).”
MethodSelf-citationLe (乐 娟), J., Yuan (袁腾 飞), T.-F., Zhang (张 艳), Y., Wang (王少 亭), S.-T., & Li (李 艳), Y. (2018) · Journal of Lipid Research · doi:10.1194/jlr.d087569 · Cited by 40
Zhang, H., Quan, L., Pei, P., Lin, Y., Feng, C., Guan, H., Wang, F., Zhang, T., Wu, J., & Huo, J. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.12.017 · Cited by 29
Metadata
- Authors
- Midttun, Ø., & Ueland, P. M.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2011-06-12
- Volume
- 25
- Issue
- 14
- Pages
- 1942-1948
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2145858476
- Cited by
- 75
- References
- 1
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.