The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
A new linear ion trap mass spectrometer
Abstract
Characteristics of mass selective axial ion ejection from a linear quadrupole ion trap in the presence of an auxiliary quadrupole field are described. Ion ejection is shown to occur through coupling of radial and axial motion in the exit fringing fields of the linear ion trap. The coupling is efficient and can result in extraction of as much as 20% of the trapped ions. This, together with the very high trapping efficiencies, can yield high sensitivity mass spectral responses. The experimental apparatus is based on the ion path of a triple quadrupole mass spectrometer allowing either the q2 collision cell or the final mass analysis quadrupole to be used as the linear trap. Space charge induced distortions of the mass resolved features while using the pressurized q2 linear ion trap occur at approximately the same ion density as reported for conventional three‐dimensional ion traps. These distortions are, however, much reduced for the lower pressure linear trap possibly owing to the proposed axial ejection mechanism that leads to ion ejection only for ions of considerable radial amplitude. RF heating due to the high ejection q ‐value and the low collision frequency may also contribute. Two hybrid RF/DC quadrupole‐linear ion trap instruments are described that provide high sensitivity product ion scanning while operated in the linear ion trap mode while also retaining all conventional triple quadrupole scan modes such as precursor ion and neutral loss scan modes. Copyright © 2002 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
New ion trap for frequency standard applications
Prestage, J. D., Dick, G. J., & Maleki, L. (1989) · Journal of Applied Physics · doi:10.1063/1.343486 · Cited by 230
A new linear ion trap time-of-flight system with tandem mass spectrometry capabilities
Campbell, J. M., Collings, B. A., & Douglas, D. J. (1998) · Rapid Communications in Mass Spectrometry · Cited by 143
A combined linear ion trap time‐of‐flight system with improved performance and MS n capabilities
Collings, B. A., Campbell, J. M., Mao, D., et al. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.440 · Cited by 98
Storage-Ring Ion Trap Derived from the Linear Quadrupole Radio-Frequency Mass Filter
Church, D. A. (1969) · Journal of Applied Physics · doi:10.1063/1.1658153 · Cited by 95
Linear Trap for High-accuracy Spectroscopy of Stored Ions
Raizen, M. G., Gilligan, J. M., Bergquist, J., Itano, W. M., & Wineland, D. J. (1992) · Journal of Modern Optics · doi:10.1080/09500349214550241 · Cited by 93
Relative dissociation energy measurements using ion trap collisional activation
Hart, K. J., & McLuckey, S. A. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85015-1 · Cited by 73
Beschleunigung von Elektronen in einem Plasmabetatron
Drees, J., & Paul, W. (1964) · The European Physical Journal A · doi:10.1007/bf01380519 · Cited by 50
Cluster experiments in radio frequency Paul traps: Collisional relaxation and dissociation
Parks, J. H., Pollack, S., & Hill, W. (1994) · The Journal of Chemical Physics · doi:10.1063/1.468361 · Cited by 33
Ion storage in the rf octupole trap
Walz, J., Siemers, I., Schubert, M., Neuhauser, W., Blatt, R., & Teloy, E. (1994) · Physical Review A · doi:10.1103/physreva.50.4122 · Cited by 24
Cited by
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Mass Spectrometry and Protein Analysis
Domon, B., & Aebersold, R. (2006) · Science · doi:10.1126/science.1124619 · Cited by 2,181
Ishihama, Y., Oda, Y., Tabata, T., Sato, T., Nagasu, T., Rappsilber, J., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500061-mcp200 · Cited by 2,055
The Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Comparative evaluation of mass spectrometry platforms used in large-scale proteomics investigations
Elias, J. E., Haas, W., Faherty, B. K., & Gygi, S. P. (2005) · Nature Methods · doi:10.1038/nmeth785 · Cited by 701
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
Linear ion traps in mass spectrometry
Douglas, D. J., Frank, A. J., & Mao, D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20004 · Cited by 459
Miniature and Fieldable Mass Spectrometers: Recent Advances
Snyder, D. T., Pulliam, C. J., Ouyang, Z., & Cooks, R. G. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03070 · Cited by 420
Multiple reaction monitoring for quantitative biomarker analysis in proteomics and metabolomics☆
Kitteringham, N. R., Jenkins, R. E., Lane, C. S., Elliott, V. L., & Park, B. K. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.11.013 · Cited by 343
Ouyang, Z., & Cooks, R. G. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155229 · Cited by 323
Olsen, J. V., & Mann, M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405549101 · Cited by 313
Mass spectrometry of peptides and proteins
Wysocki, V. H., Resing, K. A., Zhang, Q., & Cheng, G. (2005) · Methods · doi:10.1016/j.ymeth.2004.08.013 · Cited by 307
Analytical strategies for identifying drug metabolites
Prakash, C., Shaffer, C. L., & Nedderman, A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20128 · Cited by 302
Hopfgartner, G., Varesio, E., Tschäppät, V., Grivet, C., Bourgogne, E., & Leuthold, L. A. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.659 · Cited by 287
Quantitative high‐throughput analysis of drugs in biological matrices by mass spectrometry
Hopfgartner, G., & Bourgogne, E. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10050 · Cited by 266
Richards, K., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2017.01.032 · Cited by 23
Metadata
- Authors
- Hager, J. W.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2002-02-04
- Volume
- 16
- Issue
- 6
- Pages
- 512-526
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2164253249
- Cited by
- 479
- References
- 10
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.