CoChat

Pressure baseline correction and high‐precision CO 2 clumped‐isotope (∆ 47 ) measurements in bellows and micro‐volume modes

He, Bo, Olack, Gerard A., Colman, Albert S. · 2012 · Rapid Communications in Mass Spectrometry
Cited by 134

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

RATIONALE: CO 2 ‘clumped‐isotope’ measurements (tracking enrichment of 16 O 13 C 18 O, reported as ∆ 47 values, on CO 2 derived from carbonate minerals or the atmosphere) are becoming central to a wide range of geochemical investigations. We present a novel approach to address problems with instrument stability, external precision, and the analysis of small samples that have hampered the advancement of Δ 47 measurements. METHODS: We measured Δ 47 values on CO 2 gases introduced via dual inlet to an isotope ratio mass spectrometer. We developed a method for determining the 'pressure baseline' and integrating a correction to ion beam intensity measurements during analysis. We then tested this approach for both bellows and micro‐volume modes of sample introduction. Heated gas and equilibrated gas lines (Δ 47 vs. δ 47 ) established the effectiveness of this correction. RESULTS: We have determined that drift in instrument calibration that compromises Δ 47 measurements results from a shift in the baseline signal on sensitive collectors ( m/z 47, 48, and 49) that occurs when gas is admitted to the ion source. Applying a 'pressure baseline' (PBL) correction significantly stabilizes ∆ 47 measurements and reduces the dependence of ∆ 47 values on δ 47 values by up to an order of magnitude. CONCLUSIONS: PBL‐corrected heated gas and equilibrated gas calibrations in bellows and micro‐volume modes are nearly identical and stable through time. Introduction of the PBL correction, a revision to the absolute reference frame approach to determining Δ 47 values, dramatically improves the external precision of Δ 47 measurements to near instrumental analytical uncertainty (6–8 ppm (1σ) in bellows mode; 10–12 ppm in micro‐volume mode). Copyright © 2012 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/rcm.6436

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 134

Metadata

Authors
He, B., Olack, G. A., & Colman, A. S.
Venue
Rapid Communications in Mass Spectrometry
Publisher
Wiley
Published
2012-11-07
Volume
26
Issue
24
Pages
2837-2853
ISSN
  • 0951-4198 (ISSN-L)
  • 1097-0231
OpenAlex
W2165919514
Cited by
134
References
14
FWCI
12.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.