Charge detection mass spectrometry of bacteriophage P22 procapsid distributions above 20 MDa
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
RATIONALE: Charge state resolution is required to determine the masses of ions in electrospray mass spectrometry, a feat which becomes increasingly difficult as the mass increases. Charge detection mass spectrometry (CDMS) circumvents this limitation by simultaneously measuring the charge and the m / z of individual ions. In this work, we have used electrospray CDMS to determine the number of scaffolding proteins associated with bacteriophage P22 procapsids. METHODS: P22 procapsids containing a native cargo of scaffolding protein were assembled in E. coli and purified via differential centrifugation. Electrospray CDMS was used to measure their mass distribution. RESULTS: The procapsid peak was centered at 23.60 MDa, which indicates that they contain an average of ~112 scaffolding proteins. The distribution is relatively narrow, less than 31 scaffolding proteins wide. In addition, a peak at 19.84 MDa with a relative abundance of ~15% is attributed to empty capsids. Despite having the same sizes in solution, the empty capsid and the procapsid have significantly different average charges. CONCLUSIONS: The detection of empty capsids is unexpected and the process that leads to them is unknown. The average charge on the empty capsids is significantly lower than expected from the charge residue model, which probably indicates that the empty capsids have contracted in the gas phase. The scaffolding protein presumably limits the contraction of the procapsids. This work shows that electrospray CDMS can provide valuable information for masses greater than 20 MDa. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Alexander, C. G., Jürgens, M. C., Shepherd, D. A., Freund, S. M. V., Ashcroft, A. E., & Ferguson, N. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1308846110 · Cited by 85
Shepherd, D. A., Holmes, K., Rowlands, D. J., Stonehouse, N. J., & Ashcroft, A. E. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.07.028 · Cited by 25
Cited by
Snijder, J., van de Waterbeemd, M., Damoc, E., Denisov, E., Grinfeld, D., Bennett, A., Agbandje-McKenna, M., Makarov, A., & Heck, A. J. R. (2014) · Journal of the American Chemical Society · doi:10.1021/ja502616y · Cited by 168
Resolving Adeno-Associated Viral Particle Diversity With Charge Detection Mass Spectrometry
Pierson, E. E., Keifer, D. Z., Asokan, A., & Jarrold, M. F. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00883 · Cited by 152
Self-citationHarper, C. C., Elliott, A. G., Oltrogge, L. M., Savage, D. F., & Williams, E. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01669 · Cited by 84
Metadata
- Authors
- Keifer, D. Z., Pierson, E. E., Hogan, J. A., Bedwell, G. J., Prevelige, P. E., & Jarrold, M. F.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2014-01-27
- Volume
- 28
- Issue
- 5
- Pages
- 483-488
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2110094509
- Cited by
- 52
- References
- 3
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.