Simultaneous quantitation and size characterization of apolipoprotein(a) by ultra‐performance liquid chromatography/mass spectrometry
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
RATIONALE: Apolipoprotein(a) is a polymorphic glycoprotein covalently bound to apoB100 in Lp(a) particles and has been described to be both atherogenic and prothrombotic, although its exact mechanism of action is not well defined. Apolipoprotein(a) is routinely measured by immunoassays. Unfortunately, the accuracy of the measurement can be affected by the apolipoprotein(a) size (number of kringles) polymorphism in Lp(a) particles. Here we describe an ultra‐performance liquid chromatography/mass spectrometry (UPLC/MS) assay that is capable of measuring apolipoprotein(a) concentrations while simultaneously determining the number of kringles present per protein. METHODS: Plasma samples were diluted and proteins de‐lipidated with deoxycholate prior to tryptic digestion. Distinct tryptic peptides from different regions of apolipoprotein(a) were measured to determine both concentration and the number of kringles present per protein. Separation and quantitation of tryptic peptides is carried out at 700 μL/min using a 1.7 µm C18 column (2.1 × 100 mm) coupled to a Thermo Vantage triple quadrupole (QQQ) mass spectrometer with a heated electrospray ionization (HESI) source. RESULTS: This method was compared to established methods for measuring concentration (monoclonal antibody based ELISA) and size (gel‐electrophoresis) using 80 plasma samples proved by NWLRL. The slope and r 2 value for the correlation of concentrations were determined to be 0.96 and 0.98, demonstrating excellent agreement of absolute values between the UPLC/MS and ELISA methods. As measured by UPLC/MS, the average kringle number or size is smaller than determined by the electrophoretic method. CONCLUSIONS: A single UPLC/MS method was developed capable of measuring apolipoprotein(a) concentration and size (by measuring the number of kringles per protein). This assay passes criteria required for 'fit for purpose' assays including sensitivity, intra and interday reproducibility and freeze/thaw stability. While the agreement between UPLC/MS and ELISA is excellent for concentration and may provide researchers with additional tools for studying apolipoprotein(a), the dissimilarities between UPLC/MS and the electrophoretic method may also be exploited for understanding apolipoprotein(a) structure and function. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Agger, S. A., Marney, L. C., & Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.152264 · Cited by 143
Kay, R. G., Gregory, B., Grace, P. B., & Pleasance, S. (2007) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3130 · Cited by 119
Simon, R., Girod, M., Fonbonne, C., Salvador, A., Clément, Y., Lantéri, P., Amouyel, P., Lambert, J. C., & Lemoine, J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.018861 · Cited by 92
Lassman, M. E., McLaughlin, T. M., Somers, E. P., Stefanni, A. C., Chen, Z., Murphy, B. A., Bierilo, K. K., Flattery, A. M., Wong, K. K., Castro‐Perez, J. M., et al. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.5296 · Cited by 51
Self-citation
Cited by
Kronenberg, F., Mora, S., Stroes, E. S. G., Ference, B. A., Arsenault, B. J., Berglund, L., Dweck, M. R., Koschinsky, M., Lambert, G., Mach, F., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac361 · Cited by 1,449
Lipoprotein (a) measurements for clinical application
Marcovina, S. M., & Albers, J. J. (2016) · Journal of Lipid Research · doi:10.1194/jlr.r061648 · Cited by 338
Self-citationQuantifying Protein Measurands by Peptide Measurements: Where Do Errors Arise?
van den Broek, I., Romijn, F. P. H. T. M., Smit, N. P. M., van der Laarse, A., Drijfhout, J. W., van der Burgt, Y. E. M., & Cobbaert, C. M. (2015) · Journal of Proteome Research · doi:10.1021/pr5011179 · Cited by 49
Metadata
- Authors
- Lassman, M. E., McLaughlin, T. M., Zhou, H., Pan, Y., Marcovina, S. M., Laterza, O., & Roddy, T. P.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2014-04
- Volume
- 28
- Issue
- 10
- Pages
- 1101-1106
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W1841330065
- Cited by
- 50
- References
- 7
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.