Clumped isotope measurements of small carbonate samples using a high‐efficiency dual‐reservoir technique
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
RATIONALE: The measurement of multiply substituted isotopologues of CO 2 derived from carbonate has allowed the reconstruction of paleotemperatures from a single phase (CaCO 3 ), circumventing uncertainty inherent in other isotopic paleothermometers. Traditional analytical techniques require relatively large amounts of carbonate (3–8 mg per replicate), which limits the applicability of the clumped isotope proxy to certain geological materials such as marine microfossils, commonly used for paleoclimate reconstructions. METHODS: Clumped isotope ratio measurements of small samples were made on a new, high‐efficiency, dual‐reservoir sample‐preparation inlet system attached to a Thermo‐Finnigan MAT 253 mass spectrometer. Sample gas produced on the inlet is introduced from a 10 mL reservoir directly into the source via a capillary. Reference gas fills an identical 10 mL reservoir installed between the reference bellows and the capillary. The gas pressures in the two reservoirs are initially balanced, and are allowed to decrease together over the run. RESULTS: Carbonate samples from 1 mg to 2.6 mg produced Δ 47 values equivalent to those from the traditional two‐bellows method with identical single‐sample precision (1 SE = 0.005–0.015‰) and external standard error (SE = 0.006–0.015‰, n = 4–6). The size of sample needed to achieve good precision is controlled by the sensitivity of the mass spectrometer and the size of the fixed reservoirs and adjacent U‐trap installed on our inlet. CONCLUSIONS: The high‐precision clumped isotope measurements of small aliquots of carbonate obtained in this method allows for the application of this proxy to a wider range of geological sample materials, such as marine microfossils, that until now have been nearly impossible to analyze given sample size limitation. Copyright © 2014 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
13C–18O bonds in carbonate minerals: a new kind of paleothermometer
Ghosh, P., Adkins, J., Affek, H., Balta, B., Guo, W., Schauble, E. A., Schrag, D., & Eiler, J. M. (2006) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2005.11.014 · Cited by 914
Self-citationSchauble, E. A., Ghosh, P., & Eiler, J. M. (2006) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2006.02.011 · Cited by 483
Passey, B. H., Levin, N. E., Cerling, T. E., Brown, F. H., & Eiler, J. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001824107 · Cited by 449
Paleoclimate reconstruction using carbonate clumped isotope thermometry
Eiler, J. M. (2011) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2011.09.001 · Cited by 436 · cited 3×
“The clumped isotope proxy has the potential to be very useful in the field of paleoceanography due to its ability to separate the influences of temperature and the isotopic composition of seawater on δ(18)O of marine carbonates.([1]) Foraminifera, a”
BackgroundInfluentialHuntington, K. W., Eiler, J. M., Affek, H. P., Guo, W., Bonifacie, M., Yeung, L. Y., Thiagarajan, N., Passey, B., Tripati, A., Daëron, M., et al. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1614 · Cited by 436
18O13C16O in Earth’s atmosphere
Eiler, J. M., & Schauble, E. (2004) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2004.05.035 · Cited by 362 · cited 1×
“Previously, high Δ48 values were interpreted as contamination by hydrocarbons, chlorocarbons, or sulfur compounds, which produce a mass interference on mass-47 and mass-48.([22]) Conventionally, samples should plot within the envelope of calibration gas points in δ(48) vs.”
BackgroundClumped isotope thermometry of carbonatites as an indicator of diagenetic alteration
Dennis, K. J., & Schrag, D. P. (2010) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2010.04.005 · Cited by 292
Self-citationGuo, W., Mosenfelder, J. L., Goddard, W. A., & Eiler, J. M. (2009) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2009.05.071 · Cited by 262
13C–18O isotope signatures and ‘clumped isotope’ thermometry in foraminifera and coccoliths
Tripati, A. K., Eagle, R. A., Thiagarajan, N., Gagnon, A. C., Bauch, H., Halloran, P. R., & Eiler, J. M. (2010) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2010.07.006 · Cited by 240
Meckler, A. N., Ziegler, M., Millán, M. I., Breitenbach, S. F. M., & Bernasconi, S. M. (2014) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6949 · Cited by 239 · cited 4×
“In other methods using microvolumes, either the gas is not run for a very long time([11,12]) or additional corrections for fractionation in stable isotopes were necessary.”
BackgroundMethodInfluential
Cited by
Bernasconi, S. M., Müller, I. A., Bergmann, K. D., Breitenbach, S. F. M., Fernandez, A., Hodell, D. A., Jaggi, M., Meckler, A. N., Millan, I., & Ziegler, M. (2018) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2017gc007385 · Cited by 301
Petersen, S. V., Defliese, W. F., Saenger, C., Daëron, M., Huntington, K. W., John, C. M., Kelson, J. R., Bernasconi, S. M., Colman, A. S., Kluge, T., et al. (2019) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2018gc008127 · Cited by 209
“To combat this, users generally measure each sample unknown a minimum of 3 times ( n = 3 replicates of ~3 – 8 mg CaCO 3 each) or more ( n > 7 replicates of ~0.1 mg CaCO 3 with a Kiel device, Schmid & Bernasconi, 2010, or n = 4 – 6 replicates of ~1 – 1.5 mg CaCO 3 , Petersen & Schrag, 2014).”
InfluentialSelf-citationFernandez, A., Müller, I. A., Rodríguez‐Sanz, L., van Dijk, J., Looser, N., & Bernasconi, S. M. (2017) · Geochemistry, Geophysics, Geosystems · doi:10.1002/2017gc007106 · Cited by 101
Spencer, C., & Kim, S.-T. (2015) · Geosciences Journal · doi:10.1007/s12303-015-0018-1 · Cited by 44
“Alternatively, sample and reference CO2 can be stored within individual micro-volumes before the change-over valves (Fig. 3; e.g., He et al., 2012; Petersen and Schrag, 2014).”
BackgroundMethodInfluentialPetersen, S. V., Winkelstern, I. Z., Lohmann, K. C., & Meyer, K. W. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7438 · Cited by 32
Self-citationDavies, A. J., & John, C. M. (2017) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7902 · Cited by 30
Equilibrated Gas and Carbonate Standard‐Derived Dual (Δ 47 and Δ 48 ) Clumped Isotope Values
Lucarelli, J. K., Carroll, H. M., Ulrich, R. N., Elliott, B. M., Coplen, T. B., Eagle, R. A., & Tripati, A. (2023) · Geochemistry, Geophysics, Geosystems · doi:10.1029/2022gc010458 · Cited by 27
“…with replicate analyses performed from May 2015 to May 2017 ( For 1 replicate, the shot noise limits (Huntington et al., 2009; Merritt & Hayes, 1994; Petersen & Schrag, 2014) for Δ 47 and Δ 48 values determined on Nu Perspective-EG and Nu Perspective-1 were 0.008 ‰ and 0.027 ‰, respectively.”
Influential
Metadata
- Authors
- Petersen, S. V., & Schrag, D. P.
- Venue
- Rapid Communications in Mass Spectrometry
- Publisher
- Wiley
- Published
- 2014-10
- Volume
- 28
- Issue
- 21
- Pages
- 2371-2381
- ISSN
- 0951-4198 (ISSN-L)
- 1097-0231
- OpenAlex
- W2140332072
- Cited by
- 15
- References
- 18
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.